Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

M&R Complied

From the help published with Drinking Water Watch 3.5, reproduced as delivered.

The permitted Values for the M&R Complied? field are: Y=YES in compliance; NMJ=No-Major Violation; NMN=No-Minor Violation. For all summaries except IFT, the following calculation sets the default value for this field:

x = (Number of Samples Taken/Number of Samples Required)* 100

If x >= 100, default to “Y.”

If x <89.9, default to NMJ (No-Major M&R Violation).

Otherwise, default to NMN (No-Minor M&R Violation).

For Individual Filter Turbidity Summaries, the M&R Complied? field is valued based on the answer to questions about the monitoring completed and recorded during the monitoring period.