Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Total Haloacetic Acids (Haa5) results

MS0010005 , Broadmoor Utilities, Inc

18 samples have been analysed for Total Haloacetic Acids (Haa5) at Broadmoor Utilities, Inc.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Total Haloacetic Acids (Haa5) result

The table below lists 11–18 of 18 samples, newest first — collected May 5, 2004 to January 31, 2022.

8 Total Haloacetic Acids (Haa5) results from the 8 samples listed here: 5 detected, 3 not detected. Those samples also carried 25 results for other analytes, which are on the full results page.

Units in this table

Total Haloacetic Acids (Haa5) is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

Total Haloacetic Acids (Haa5) results for Broadmoor Utilities, Inc, from 11 to 18 of 18 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jan 31, 2022 15:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
HA-220201-018
Laboratory
MSDH Lab
1.71 ug/l , sample collected Jan 31, 2022 15:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Not recorded
Collected
Mar 12, 2019 16:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
190313-007HA
Laboratory
MSDH Lab
0.021 mg/l , sample collected Mar 12, 2019 16:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2017 – Dec 31, 2019
Collected
Aug 29, 2017 16:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
170830-011HA
Laboratory
MSDH Lab
0.02 mg/l , sample collected Aug 29, 2017 16:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2017 – Dec 31, 2019
Collected
Jul 21, 2014 04:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
140722-032HA
Laboratory
MSDH Lab
0.001 mg/l , sample collected Jul 21, 2014 04:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2014 – Dec 31, 2016
Collected
Jul 6, 2011
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110707-001HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Jul 6, 2011, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2011 – Dec 31, 2013
Collected
Jul 14, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080715-002HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Jul 14, 2008, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2008 – Dec 31, 2010
Collected
Jun 25, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070626-028HA
Laboratory
MSDH Lab
0.006 mg/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 25, 2007, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2005 – Dec 31, 2007
Collected
May 5, 2004
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
040506-011HA
Laboratory
MSDH Lab
Not detected below 0.01 mg/l Minimum Reporting Level , sample collected May 5, 2004, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2004 – Dec 31, 2004

Routine (8).