Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

TTHM results

MS0030001 , Coles Water Association #1

26 samples have been analysed for TTHM at Coles Water Association #1.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every TTHM result

The table below lists 21–26 of 26 samples, newest first — collected May 3, 2004 to August 29, 2017.

6 TTHM results from the 6 samples listed here: 3 detected, 3 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.

Units in this table

TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

TTHM results for Coles Water Association #1, from 21 to 26 of 26 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Aug 29, 2017 14:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
170830-010TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Aug 29, 2017 14:00, sampling point MRT000 TTHM 2950 Jan 1, 2017 – Dec 31, 2019
Collected
Jul 28, 2014 02:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
140729-013TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Jul 28, 2014 02:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2014 – Dec 31, 2016
Collected
Jul 5, 2011 01:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110706-007TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Jul 5, 2011 01:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2011 – Dec 31, 2013
Collected
Jun 8, 2010
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
100609-011TH
Laboratory
MSDH Lab
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 8, 2010, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2008 – Dec 31, 2010
Collected
Jun 25, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070626-006TH
Laboratory
MSDH Lab
10.63 ug/l , sample collected Jun 25, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2005 – Dec 31, 2007
Collected
May 3, 2004
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
040504-042TH
Laboratory
MSDH Lab
6.63 ug/l , sample collected May 3, 2004, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2004 – Dec 31, 2004

Routine (6).