Chemical and radiological sample results

MS0030005 , Mary Springs Water Association

21 of the 55 analytes this system has been tested for have been detected at least once, across 359 samples on record.

The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 359 samples on record, detections range from August 16, 1993 to July 21, 2026. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Mary Springs Water Association, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Lead 1030 Inorganic Chemical 161 of 222 results Aug 16, 1993 Jul 21, 2026
Copper, Free 1022 Inorganic Chemical 153 of 222 results Jun 5, 1995 Jul 21, 2026
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 11 of 31 results Jun 26, 2007 Apr 8, 2025
Xylenes, Total 2955 Organic Chemical 10 of 38 results Oct 18, 2010 Aug 25, 2021
Arsenic 1005 Inorganic Chemical 5 of 5 results Apr 18, 2011 Jan 9, 2024
Barium 1010 Inorganic Chemical 5 of 5 results Apr 18, 2011 Jan 9, 2024
Nickel 1036 Inorganic Chemical 5 of 5 results Apr 18, 2011 Jan 9, 2024
Gross Alpha, Incl. Radon & U 4002 Radionuclide 5 of 5 results Dec 5, 2011 Jul 10, 2012
Combined Radium (-226 & -228) 4010 Radionuclide 5 of 5 results Dec 5, 2011 Jul 10, 2012
Radium-226 4020 Radionuclide 5 of 5 results Dec 5, 2011 Jul 10, 2012
Chromium 1020 Inorganic Chemical 4 of 5 results May 5, 2014 Jan 9, 2024
TTHM 2950 Organic Chemical 4 of 31 results May 3, 2004 Sep 28, 2010
Sodium 1052 Inorganic Chemical 3 of 3 results Sep 16, 2019 Oct 16, 2024
Nitrate-Nitrite 1038 Inorganic Chemical 3 of 17 results Mar 14, 2016 Jan 6, 2022
Nitrate 1040 Inorganic Chemical 3 of 17 results Mar 14, 2016 Jan 6, 2022
Nitrite 1041 Inorganic Chemical 2 of 17 results Jan 6, 2022 Jan 11, 2023
Fluoride 1025 Inorganic Chemical 1 of 5 results Jan 9, 2024 Jan 9, 2024
Monochloroacetic Acid 2450 Organic Chemical 1 of 8 results Sep 12, 2017 Sep 12, 2017
Dichloroacetic Acid 2451 Organic Chemical 1 of 8 results Jul 18, 2011 Jul 18, 2011
Trichloroacetic Acid 2452 Organic Chemical 1 of 8 results Jul 18, 2011 Jul 18, 2011
Monobromoacetic Acid 2453 Organic Chemical 1 of 8 results Jul 18, 2011 Jul 18, 2011

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 231–240 of 359 samples, newest first — collected October 18, 2010 to March 22, 2011. The summary above covers all 359.

41 results from the 10 samples listed here: 14 detected, 27 not detected. Across the whole record it is 389 of 1,514. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Mary Springs Water Association, every result from 231 to 240 of 359 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-016PB
Laboratory
MSDH Lab
0.6427 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0031 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-015PB
Laboratory
MSDH Lab
0.565 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0028 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-014PB
Laboratory
MSDH Lab
0.0462 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0034 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-013PB
Laboratory
MSDH Lab
0.5951 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0014 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-012PB
Laboratory
MSDH Lab
0.4266 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0007 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Mar 22, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110325-011PB
Laboratory
MSDH Lab
0.1179 mg/l , sample collected Mar 22, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
0.0045 mg/l , sample collected Mar 22, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2011 – Jun 30, 2011
Collected
Jan 24, 2011
Sampling point
TF080
Sample type
Routine
Lab sample
110125-012VO
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,2,4-Trichlorobenzene 2378 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Cis-1,2-Dichloroethylene 2380 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Xylenes, Total 2955 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Dichloromethane 2964 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 O-Dichlorobenzene 2968 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 P-Dichlorobenzene 2969 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Vinyl Chloride 2976 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,1-Dichloroethylene 2977 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Trans-1,2-Dichloroethylene 2979 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,2-Dichloroethane 2980 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,1,1-Trichloroethane 2981 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Carbon Tetrachloride 2982 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,2-Dichloropropane 2983 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Trichloroethylene 2984 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 1,1,2-Trichloroethane 2985 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Tetrachloroethylene 2987 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Chlorobenzene 2989 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Benzene 2990 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Toluene 2991 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Ethylbenzene 2992 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 24, 2011, sampling point TF080 Styrene 2996 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Collected
Jan 18, 2011
Sampling point
TF080
Sample type
Routine
Lab sample
110119-007NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 18, 2011, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 18, 2011, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 18, 2011, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
Collected
Nov 29, 2010
Sampling point
TF080
Sample type
Routine
Lab sample
101130-005NI
Laboratory
MSDH Lab
Not detected below 0.25 mg/l Minimum Reporting Level , sample collected Nov 29, 2010, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
Not detected below 0.2 mg/l Minimum Reporting Level , sample collected Nov 29, 2010, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
Not detected below 0.05 mg/l Minimum Reporting Level , sample collected Nov 29, 2010, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
Collected
Oct 18, 2010
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
101020-022PB
Laboratory
MSDH Lab
0.555 mg/l , sample collected Oct 18, 2010, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jul 1, 2010 – Dec 31, 2010
0.0009 mg/l , sample collected Oct 18, 2010, sampling point DS000 Lead 1030 EPA method 200.8 Jul 1, 2010 – Dec 31, 2010

Routine (10).