Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0060011 , Lamont Water Corporation

17 of the 58 analytes this system has been tested for have been detected at least once, across 165 samples on record.

The other 41 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 165 samples on record, detections range from November 30, 1993 to June 2, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Lamont Water Corporation, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 53 of 82 results Nov 30, 1993 Jun 2, 2025
Lead 1030 Inorganic Chemical 40 of 82 results Nov 30, 1993 Jun 2, 2025
Barium 1010 Inorganic Chemical 14 of 14 results Jan 29, 2002 Jan 13, 2025
Fluoride 1025 Inorganic Chemical 14 of 14 results Jan 29, 2002 Jan 13, 2025
Nitrite 1041 Inorganic Chemical 8 of 22 results Jun 7, 2006 Jan 13, 2025
Chromium 1020 Inorganic Chemical 7 of 14 results Jan 29, 2002 Jan 13, 2025
Selenium 1045 Inorganic Chemical 4 of 14 results Jan 12, 2004 Mar 12, 2008
Sodium 1052 Inorganic Chemical 3 of 3 results Sep 16, 2019 Nov 4, 2024
Nickel 1036 Inorganic Chemical 3 of 14 results Mar 12, 2008 May 2, 2022
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 3 of 8 results Jun 27, 2007 Aug 4, 2014
Trichloroacetic Acid 2452 Organic Chemical 2 of 4 results Jul 14, 2011 Aug 4, 2014
Gross Alpha Particle Activity 4109 Radionuclide 2 of 4 results Jun 25, 2012 Sep 19, 2012
TTHM 2950 Organic Chemical 2 of 8 results Jun 27, 2007 Jul 15, 2008
Arsenic 1005 Inorganic Chemical 1 of 14 results Jan 13, 2025 Jan 13, 2025
Nitrate-Nitrite 1038 Inorganic Chemical 1 of 22 results Jan 20, 2021 Jan 20, 2021
Dichloroacetic Acid 2451 Organic Chemical 1 of 4 results Jul 14, 2011 Jul 14, 2011
Cadmium 1015 Inorganic Chemical 1 of 14 results Feb 14, 2005 Feb 14, 2005

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 61–70 of 165 samples, newest first — collected September 28, 2011 to June 30, 2014. The summary above covers all 165.

37 results from the 10 samples listed here: 8 detected, 29 not detected. Across the whole record it is 159 of 721. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Lamont Water Corporation, every result from 61 to 70 of 165 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jun 30, 2014 07:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
140701-026PB
Laboratory
MSDH Lab
0.014 mg/l , sample collected Jun 30, 2014 07:00, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2012 – Dec 31, 2014
0.0026 mg/l , sample collected Jun 30, 2014 07:00, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2012 – Dec 31, 2014
Collected
Jun 25, 2014 12:25
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
140626-010CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Jun 25, 2014 12:25, sampling point TF101 Cyanide 1024 EPA method QC10204001X Jan 1, 2014 – Dec 31, 2016
Collected
May 5, 2014 12:15
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
140506-064IN
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Arsenic 1005 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
0.0095 mg/l , sample collected May 5, 2014 12:15, sampling point TF101 Barium 1010 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Cadmium 1015 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
0.0074 mg/l , sample collected May 5, 2014 12:15, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
0.358 mg/l , sample collected May 5, 2014 12:15, sampling point TF101 Fluoride 1025 EPA method 300.0 Jan 1, 2014 – Dec 31, 2016
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Mercury 1035 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
0.0006 mg/l , sample collected May 5, 2014 12:15, sampling point TF101 Nickel 1036 EPA method 200.8 Not recorded
Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Selenium 1045 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Antimony, Total 1074 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Beryllium, Total 1075 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 5, 2014 12:15, sampling point TF101 Thallium, Total 1085 EPA method 200.8 Jan 1, 2014 – Dec 31, 2016
Collected
Jan 21, 2014 12:10
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
140122-004NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 21, 2014 12:10, sampling point TF101 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2014 – Dec 31, 2014
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 21, 2014 12:10, sampling point TF101 Nitrate 1040 EPA method QC10107041C Jan 1, 2014 – Dec 31, 2014
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 21, 2014 12:10, sampling point TF101 Nitrite 1041 EPA method QC10107041C Jan 1, 2014 – Dec 31, 2014
Collected
Jan 23, 2013 03:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
130125-001NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 03:00, sampling point TF101 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 03:00, sampling point TF101 Nitrate 1040 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 03:00, sampling point TF101 Nitrite 1041 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Collected
Sep 19, 2012 12:40
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201212140251
Laboratory
Radiation Safety Engineering
0.6 pci/l , sample collected Sep 19, 2012 12:40, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 00-02 Not recorded
Collected
Jun 25, 2012 13:50
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201208210309
Laboratory
Radiation Safety Engineering
0.6 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 25, 2012 13:50, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 00-02 Not recorded
Collected
Jan 17, 2012 02:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120118-098NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 17, 2012 02:30, sampling point TF101 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 17, 2012 02:30, sampling point TF101 Nitrate 1040 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 17, 2012 02:30, sampling point TF101 Nitrite 1041 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Collected
Dec 5, 2011 13:27
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
291684001
Laboratory
Gel Laboratories
Not detected below 2.86 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Gross Alpha, Excl. Radon & U 4000 Oct 1, 2011 – Dec 31, 2011
Not detected below 0.067 ug/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Oct 1, 2011 – Dec 31, 2011
Not detected below 0.658 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.249 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Radium-226 4020 EPA method 903.1 Oct 1, 2011 – Dec 31, 2011
Not detected below 0.658 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Radium-228 4030 EPA method 904.0 Oct 1, 2011 – Dec 31, 2011
Not detected below 2.86 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:27, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 900.0 Oct 1, 2011 – Dec 31, 2011
Collected
Sep 28, 2011 13:35
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
287362003
Laboratory
Gel Laboratories
Not detected below 2.85 pci/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Gross Alpha, Excl. Radon & U 4000 Jul 1, 2011 – Sep 30, 2011
Not detected below 0.067 ug/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Jul 1, 2011 – Sep 30, 2011
Not detected below 0.876 pci/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.876 pci/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Radium-226 4020 EPA method 903.1 Jul 1, 2011 – Sep 30, 2011
Not detected below 0.363 pci/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Radium-228 4030 EPA method 904.0 Jul 1, 2011 – Sep 30, 2011
Not detected below 2.85 pci/l Minimum Reporting Level , sample collected Sep 28, 2011 13:35, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 900.0 Jul 1, 2011 – Sep 30, 2011

Routine (10).