This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Dibromochloromethane results
MS0060013 , City of Mound Bayou
9 samples have been analysed for Dibromochloromethane at City of Mound Bayou.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Dibromochloromethane result
All 9 samples analysed for this analyte are listed below, newest first. No date range is applied.
9 Dibromochloromethane results from the 9 samples listed here: 4 detected, 5 not detected. Those samples also carried 42 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 4.4 ug/l , sample collected Nov 6, 2025 11:40, sampling point DS000 | Dibromochloromethane 2944 EPA method 524.2 | Jan 1, 2025 – Dec 31, 2025 |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jul 16, 2020 11:15, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| 1.06 ug/l , sample collected Jul 10, 2019 03:30, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected May 16, 2019 05:30, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 7, 2017 15:01, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 24, 2015 12:00, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| 16.5 ug/l , sample collected Jul 12, 2011 01:10, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jul 16, 2008, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
|
||
| 16 ug/l , sample collected Jun 28, 2007, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
-
- Collected
- Nov 6, 2025 11:40
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 810-170994-1
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2025 – Dec 31, 2025
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- 4.4 ug/l
-
- Collected
- Jul 16, 2020 11:15
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 200717-003TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Jul 10, 2019 03:30
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 190711-020TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- 1.06 ug/l
-
- Collected
- May 16, 2019 05:30
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 190517-002TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Sep 7, 2017 15:01
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 170908-006TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Jun 24, 2015 12:00
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 150625-011TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Jul 12, 2011 01:10
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 110713-004TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- 16.5 ug/l
-
- Collected
- Jul 16, 2008
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 080717-004TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Jun 28, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070629-003TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- 16 ug/l
Routine (9).