This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Radium-226 results
MS0060017 , Scott Combined Water & Sewer D
10 samples have been analysed for Radium-226 at Scott Combined Water & Sewer D.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Radium-226 result
All 10 samples analysed for this analyte are listed below, newest first. No date range is applied.
10 Radium-226 results from the 10 samples listed here: 0 detected, 10 not detected. Those samples also carried 30 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.192 pci/l Minimum Reporting Level , sample collected Jul 13, 2012 13:40, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.265 pci/l Minimum Reporting Level , sample collected Jul 13, 2012 13:53, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.192 pci/l Minimum Reporting Level , sample collected Jul 12, 2012 11:45, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.265 pci/l Minimum Reporting Level , sample collected Jul 12, 2012 11:30, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.192 pci/l Minimum Reporting Level , sample collected Apr 19, 2012 13:30, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.265 pci/l Minimum Reporting Level , sample collected Apr 19, 2012 13:42, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.192 pci/l Minimum Reporting Level , sample collected Feb 15, 2012 13:30, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.265 pci/l Minimum Reporting Level , sample collected Feb 15, 2012 13:40, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.192 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:40, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Oct 1, 2011 – Dec 31, 2011 |
|
||
| Not detected below 0.265 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:53, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Oct 1, 2011 – Dec 31, 2011 |
-
- Collected
- Jul 13, 2012 13:40
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 201211140426
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.192 pci/l Minimum Reporting Level
-
- Collected
- Jul 13, 2012 13:53
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201211140417
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.265 pci/l Minimum Reporting Level
-
- Collected
- Jul 12, 2012 11:45
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120713-017
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.192 pci/l Minimum Reporting Level
-
- Collected
- Jul 12, 2012 11:30
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120713-018
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.265 pci/l Minimum Reporting Level
-
- Collected
- Apr 19, 2012 13:30
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120420-013
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.192 pci/l Minimum Reporting Level
-
- Collected
- Apr 19, 2012 13:42
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120420-014
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.265 pci/l Minimum Reporting Level
-
- Collected
- Feb 15, 2012 13:30
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120216-019
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.192 pci/l Minimum Reporting Level
-
- Collected
- Feb 15, 2012 13:40
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120216-020
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.265 pci/l Minimum Reporting Level
-
- Collected
- Dec 5, 2011 13:40
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 111206-022
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2011 – Dec 31, 2011
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.192 pci/l Minimum Reporting Level
-
- Collected
- Dec 5, 2011 13:53
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 111206-023
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2011 – Dec 31, 2011
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.265 pci/l Minimum Reporting Level
Routine (10).