Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0070004 , City of Calhoun City

25 of the 59 analytes this system has been tested for have been detected at least once, across 354 samples on record.

The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 354 samples on record, detections range from December 20, 1993 to April 29, 2026. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for City of Calhoun City, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 148 of 161 results Dec 20, 1993 Sep 30, 2025
Lead 1030 Inorganic Chemical 124 of 161 results Dec 20, 1993 Sep 30, 2025
Barium 1010 Inorganic Chemical 28 of 28 results Jun 25, 2002 Mar 3, 2025
Fluoride 1025 Inorganic Chemical 28 of 28 results Jun 25, 2002 Mar 3, 2025
Arsenic 1005 Inorganic Chemical 26 of 28 results Jun 25, 2002 Mar 3, 2025
Selenium 1045 Inorganic Chemical 25 of 28 results Jun 25, 2002 Mar 3, 2025
Nitrate-Nitrite 1038 Inorganic Chemical 24 of 56 results May 3, 2004 Feb 25, 2026
Nickel 1036 Inorganic Chemical 24 of 28 results Jun 25, 2002 Mar 3, 2025
Nitrate 1040 Inorganic Chemical 20 of 56 results May 3, 2004 Mar 3, 2025
Chromium 1020 Inorganic Chemical 19 of 28 results Jun 25, 2002 May 2, 2022
Nitrite 1041 Inorganic Chemical 16 of 56 results May 3, 2004 Feb 25, 2026
Gross Alpha, Incl. Radon & U 4002 Radionuclide 14 of 14 results Mar 13, 2012 Oct 18, 2012
Sodium 1052 Inorganic Chemical 6 of 6 results Sep 18, 2019 Dec 9, 2024
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 6 of 14 results Jun 26, 2007 Mar 4, 2024
TTHM 2950 Organic Chemical 4 of 13 results Jun 26, 2007 Apr 29, 2026
Combined Radium (-226 & -228) 4010 Radionuclide 4 of 14 results Mar 13, 2012 Oct 16, 2012
Radium-226 4020 Radionuclide 4 of 14 results Mar 13, 2012 Oct 16, 2012
Radium-228 4030 Radionuclide 4 of 14 results Mar 13, 2012 Oct 16, 2012
Gross Alpha Particle Activity 4109 Radionuclide 4 of 4 results Mar 13, 2012 Oct 16, 2012
Bromoform 2942 Organic Chemical 2 of 7 results Apr 28, 2020 Apr 29, 2026
Dichloroacetic Acid 2451 Organic Chemical 1 of 8 results Apr 28, 2020 Apr 28, 2020
Monobromoacetic Acid 2453 Organic Chemical 1 of 8 results Aug 13, 2014 Aug 13, 2014
Dibromoacetic Acid 2454 Organic Chemical 1 of 8 results Aug 11, 2008 Aug 11, 2008
Cadmium 1015 Inorganic Chemical 1 of 28 results Feb 16, 2005 Feb 16, 2005
Antimony, Total 1074 Inorganic Chemical 1 of 28 results Feb 16, 2005 Feb 16, 2005

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 141–150 of 354 samples, newest first — collected March 13, 2012 to May 16, 2012. The summary above covers all 354.

30 results from the 10 samples listed here: 14 detected, 16 not detected. Across the whole record it is 535 of 1,511. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for City of Calhoun City, every result from 141 to 150 of 354 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
May 16, 2012 14:20
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120517-014
Laboratory
Radiation Safety Engineering
0.4 pci/l , sample collected May 16, 2012 14:20, sampling point TF103 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected May 16, 2012 14:20, sampling point TF103 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected May 16, 2012 14:20, sampling point TF103 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected May 16, 2012 14:20, sampling point TF103 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
May 16, 2012 13:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120517-035
Laboratory
Radiation Safety Engineering
0.7 pci/l , sample collected May 16, 2012 13:30, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected May 16, 2012 13:30, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected May 16, 2012 13:30, sampling point TF102 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Not detected below 0.26 pci/l Minimum Reporting Level , sample collected May 16, 2012 13:30, sampling point TF102 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
May 16, 2012 13:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120517-034
Laboratory
Radiation Safety Engineering
10.1 pci/l , sample collected May 16, 2012 13:00, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
5.7 pci/l , sample collected May 16, 2012 13:00, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
5.1 pci/l , sample collected May 16, 2012 13:00, sampling point TF101 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
0.6 pci/l , sample collected May 16, 2012 13:00, sampling point TF101 Radium-228 4030 EPA method 904 Apr 1, 2012 – Jun 30, 2012
10.1 pci/l , sample collected May 16, 2012 13:00, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 00-02 Apr 1, 2012 – Jun 30, 2012
Collected
May 16, 2012 13:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120517-035RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 16, 2012 13:30, sampling point TF102 Combined Uranium 4006 EPA method 200.8 Apr 1, 2012 – Jun 30, 2012
Collected
May 16, 2012 13:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120517-034RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 16, 2012 13:00, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Apr 1, 2012 – Jun 30, 2012
Collected
May 16, 2012 14:20
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120517-014RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 16, 2012 14:20, sampling point TF103 Combined Uranium 4006 EPA method 200.8 Apr 1, 2012 – Jun 30, 2012
Collected
Mar 13, 2012 14:10
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120314-074
Laboratory
Radiation Safety Engineering
0.4 pci/l , sample collected Mar 13, 2012 14:10, sampling point TF103 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 14:10, sampling point TF103 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 14:10, sampling point TF103 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 14:10, sampling point TF103 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012
Collected
Mar 13, 2012 15:20
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120314-073
Laboratory
Radiation Safety Engineering
0.7 pci/l , sample collected Mar 13, 2012 15:20, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 15:20, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.272 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 15:20, sampling point TF102 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Not detected below 0.26 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 15:20, sampling point TF102 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012
Collected
Mar 13, 2012 15:40
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120314-072
Laboratory
Radiation Safety Engineering
10.1 pci/l , sample collected Mar 13, 2012 15:40, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
5.7 pci/l , sample collected Mar 13, 2012 15:40, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
5.1 pci/l , sample collected Mar 13, 2012 15:40, sampling point TF101 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
0.6 pci/l , sample collected Mar 13, 2012 15:40, sampling point TF101 Radium-228 4030 EPA method 904 Jan 1, 2012 – Mar 31, 2012
10.1 pci/l , sample collected Mar 13, 2012 15:40, sampling point TF101 Gross Alpha Particle Activity 4109 EPA method 00-02 Jan 1, 2012 – Mar 31, 2012
Collected
Mar 13, 2012 14:10
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120314-074RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 13, 2012 14:10, sampling point TF103 Combined Uranium 4006 EPA method 200.8 Jan 1, 2012 – Mar 31, 2012

Routine (10).