This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0070015 , Town of Pittsboro
23 of the 57 analytes this system has been tested for have been detected at least once, across 401 samples on record.
The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 401 samples on record, detections range from August 2, 1993 to July 30, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 202 of 243 results | Aug 2, 1993 | Jul 30, 2026 |
| Lead 1030 | Inorganic Chemical | 195 of 243 results | Aug 2, 1993 | Jul 30, 2026 |
| Barium 1010 | Inorganic Chemical | 22 of 22 results | Jul 9, 2002 | Jan 14, 2025 |
| Fluoride 1025 | Inorganic Chemical | 22 of 22 results | Jul 9, 2002 | Jan 14, 2025 |
| Arsenic 1005 | Inorganic Chemical | 19 of 22 results | Jul 9, 2002 | Jan 14, 2025 |
| Selenium 1045 | Inorganic Chemical | 19 of 22 results | Jul 9, 2002 | Jan 14, 2025 |
| Chromium 1020 | Inorganic Chemical | 17 of 22 results | Jan 12, 2004 | Jan 14, 2025 |
| Nickel 1036 | Inorganic Chemical | 12 of 22 results | Jul 9, 2002 | Jan 14, 2025 |
| TTHM 2950 | Organic Chemical | 11 of 20 results | May 17, 2004 | Aug 7, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 10 of 10 results | Dec 7, 2011 | Jul 11, 2012 |
| Bromoform 2942 | Organic Chemical | 9 of 14 results | Feb 19, 2024 | Aug 7, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 9 of 14 results | Feb 19, 2024 | Aug 7, 2025 |
| Dibromoacetic Acid 2454 | Organic Chemical | 7 of 14 results | Feb 19, 2024 | Aug 7, 2025 |
| Sodium 1052 | Inorganic Chemical | 6 of 6 results | Oct 1, 2019 | Oct 22, 2024 |
| Nitrite 1041 | Inorganic Chemical | 6 of 46 results | May 5, 2008 | Jan 10, 2024 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 6 of 46 results | May 5, 2004 | Jan 14, 2020 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 5 of 20 results | Jun 27, 2007 | Aug 7, 2025 |
| Nitrate 1040 | Inorganic Chemical | 5 of 46 results | May 5, 2004 | Jan 14, 2020 |
| Cadmium 1015 | Inorganic Chemical | 1 of 22 results | May 3, 2022 | May 3, 2022 |
| Antimony, Total 1074 | Inorganic Chemical | 1 of 22 results | May 3, 2022 | May 3, 2022 |
| Beryllium, Total 1075 | Inorganic Chemical | 1 of 22 results | May 3, 2022 | May 3, 2022 |
| Thallium, Total 1085 | Inorganic Chemical | 1 of 22 results | May 3, 2022 | May 3, 2022 |
| Dichloroacetic Acid 2451 | Organic Chemical | 1 of 14 results | Aug 13, 2014 | Aug 13, 2014 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 71–80 of 401 samples, newest first — collected October 1, 2019 to January 20, 2021. The summary above covers all 401.
38 results from the 10 samples listed here: 20 detected, 18 not detected. Across the whole record it is 587 of 1,448. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
Units in this table
Sodium is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 179 mg/l , sample collected Jan 20, 2021 13:00, sampling point TF103 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| 182 mg/l , sample collected Jan 20, 2021 13:20, sampling point TF102 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:35, sampling point TF103 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:35, sampling point TF103 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:35, sampling point TF103 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:05, sampling point TF102 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:05, sampling point TF102 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 20, 2021 12:05, sampling point TF102 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2021 – Dec 31, 2021 |
|
||
| 0.0018 mg/l , sample collected Apr 8, 2020 14:15, sampling point TF103 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.032 mg/l , sample collected Apr 8, 2020 14:15, sampling point TF103 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0013 mg/l , sample collected Apr 8, 2020 14:15, sampling point TF103 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.502 mg/l , sample collected Apr 8, 2020 14:15, sampling point TF103 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Nickel 1036 EPA method 200.8 | Not recorded |
| 0.0054 mg/l , sample collected Apr 8, 2020 14:15, sampling point TF103 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:15, sampling point TF103 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
|
||
| 0.0017 mg/l , sample collected Apr 8, 2020 14:00, sampling point TF102 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0345 mg/l , sample collected Apr 8, 2020 14:00, sampling point TF102 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0013 mg/l , sample collected Apr 8, 2020 14:00, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.493 mg/l , sample collected Apr 8, 2020 14:00, sampling point TF102 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Nickel 1036 EPA method 200.8 | Not recorded |
| 0.0054 mg/l , sample collected Apr 8, 2020 14:00, sampling point TF102 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 8, 2020 14:00, sampling point TF102 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
|
||
| 0.34 mg/l , sample collected Jan 14, 2020 12:25, sampling point TF103 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| 0.29 mg/l , sample collected Jan 14, 2020 12:25, sampling point TF103 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| 0.05 mg/l , sample collected Jan 14, 2020 12:25, sampling point TF103 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
|
||
| 0.35 mg/l , sample collected Jan 14, 2020 12:10, sampling point TF102 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| 0.3 mg/l , sample collected Jan 14, 2020 12:10, sampling point TF102 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| 0.05 mg/l , sample collected Jan 14, 2020 12:10, sampling point TF102 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
|
||
| 220000 ug/l , sample collected Oct 1, 2019 10:30, sampling point TF103 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| 230000 ug/l , sample collected Oct 1, 2019 10:45, sampling point TF102 | Sodium 1052 EPA method 200.7 | Not recorded |
-
- Collected
- Jan 20, 2021 13:00
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- NA-210121-006
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 179 mg/l
-
- Collected
- Jan 20, 2021 13:20
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- NA-210121-005
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 182 mg/l
-
- Collected
- Jan 20, 2021 12:35
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- NI-210121-048
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2021 – Dec 31, 2021
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jan 20, 2021 12:05
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- NI-210121-047
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2021 – Dec 31, 2021
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Apr 8, 2020 14:15
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 200409-033IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- 0.0018 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.032 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- 0.0013 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 0.502 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- 0.0054 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
- Collected
- Apr 8, 2020 14:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 200409-032IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- 0.0017 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.0345 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- 0.0013 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 0.493 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- 0.0054 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
- Collected
- Jan 14, 2020 12:25
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 200115-032NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2020
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- 0.34 mg/l
-
Nitrate 1040 EPA method QC10107041C
- Result
- 0.29 mg/l
-
Nitrite 1041 EPA method QC10107041C
- Result
- 0.05 mg/l
-
- Collected
- Jan 14, 2020 12:10
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 200115-031NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2020
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- 0.35 mg/l
-
Nitrate 1040 EPA method QC10107041C
- Result
- 0.3 mg/l
-
Nitrite 1041 EPA method QC10107041C
- Result
- 0.05 mg/l
-
- Collected
- Oct 1, 2019 10:30
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 680-175066-42
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 220000 ug/l
-
- Collected
- Oct 1, 2019 10:45
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 680-175066-43
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 230000 ug/l
Routine (10).