This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0070019 , Town of Vardaman
22 of the 58 analytes this system has been tested for have been detected at least once, across 341 samples on record.
The other 36 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 341 samples on record, detections range from August 31, 1993 to August 13, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 92 of 149 results | Aug 31, 1993 | Aug 13, 2025 |
| Lead 1030 | Inorganic Chemical | 86 of 149 results | Aug 31, 1993 | Aug 13, 2025 |
| Barium 1010 | Inorganic Chemical | 28 of 28 results | Jun 25, 2002 | Jan 15, 2025 |
| Fluoride 1025 | Inorganic Chemical | 28 of 28 results | Jun 25, 2002 | Jan 15, 2025 |
| Arsenic 1005 | Inorganic Chemical | 27 of 28 results | Jun 25, 2002 | Jan 15, 2025 |
| Nickel 1036 | Inorganic Chemical | 22 of 28 results | Jun 25, 2002 | Jan 15, 2025 |
| Chromium 1020 | Inorganic Chemical | 20 of 28 results | Jun 25, 2002 | Jan 15, 2025 |
| Selenium 1045 | Inorganic Chemical | 20 of 28 results | Jun 25, 2002 | May 2, 2022 |
| TTHM 2950 | Organic Chemical | 12 of 20 results | Aug 8, 2007 | May 12, 2025 |
| Nitrite 1041 | Inorganic Chemical | 11 of 55 results | May 5, 2004 | Jan 20, 2015 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 10 of 10 results | Dec 8, 2011 | Jul 11, 2012 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 9 of 55 results | May 3, 2004 | Jan 23, 2013 |
| Bromoform 2942 | Organic Chemical | 8 of 15 results | Sep 6, 2017 | May 12, 2025 |
| Nitrate 1040 | Inorganic Chemical | 7 of 55 results | May 3, 2004 | Jun 7, 2006 |
| Sodium 1052 | Inorganic Chemical | 6 of 6 results | Sep 30, 2019 | Oct 14, 2024 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 5 of 23 results | Jun 28, 2007 | Jun 3, 2019 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 5 of 10 results | Dec 8, 2011 | Jul 11, 2012 |
| Radium-228 4030 | Radionuclide | 5 of 10 results | Dec 8, 2011 | Jul 11, 2012 |
| Monobromoacetic Acid 2453 | Organic Chemical | 2 of 16 results | Aug 27, 2014 | Aug 27, 2014 |
| Cadmium 1015 | Inorganic Chemical | 2 of 28 results | Feb 16, 2005 | Feb 16, 2005 |
| Dichloroacetic Acid 2451 | Organic Chemical | 1 of 16 results | Jun 3, 2019 | Jun 3, 2019 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 16 results | Jun 3, 2019 | Jun 3, 2019 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 131–140 of 341 samples, newest first — collected July 10, 2012 to January 23, 2013. The summary above covers all 341.
30 results from the 10 samples listed here: 13 detected, 17 not detected. Across the whole record it is 407 of 1,469. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:40, sampling point TF103 | Nitrate-Nitrite 1038 EPA method 353.2 | Not recorded |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:40, sampling point TF103 | Nitrate 1040 EPA method 353.2 | Not recorded |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:40, sampling point TF103 | Nitrite 1041 EPA method 353.2 | Not recorded |
|
||
| 0.18 mg/l , sample collected Jan 23, 2013 01:10, sampling point TF102 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:10, sampling point TF102 | Nitrate 1040 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| 0.16 mg/l , sample collected Jan 23, 2013 01:10, sampling point TF102 | Nitrite 1041 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:00, sampling point TF101 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 23, 2013 01:00, sampling point TF101 | Nitrate 1040 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| 0.02 mg/l , sample collected Jan 23, 2013 01:00, sampling point TF101 | Nitrite 1041 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
|
||
| 0.2 mg/l , sample collected Nov 5, 2012 02:00, sampling point TF101 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Nov 5, 2012 02:00, sampling point TF101 | Nitrate 1040 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
| 0.14 mg/l , sample collected Nov 5, 2012 02:00, sampling point TF101 | Nitrite 1041 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 6.1 mfl Minimum Reporting Level , sample collected Sep 11, 2012 09:00, sampling point DS000 | Asbestos 1094 EPA method 100.2 | Jan 1, 2011 – Dec 31, 2019 |
|
||
| 1.4 pci/l , sample collected Jul 11, 2012 13:40, sampling point TF101 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| 0.6 pci/l , sample collected Jul 11, 2012 13:40, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.201 pci/l Minimum Reporting Level , sample collected Jul 11, 2012 13:40, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| 0.6 pci/l , sample collected Jul 11, 2012 13:40, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 1.7 pci/l , sample collected Jul 11, 2012 14:00, sampling point TF102 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Jul 11, 2012 14:00, sampling point TF102 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Jul 11, 2012 14:00, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| Not detected below 0.39 pci/l Minimum Reporting Level , sample collected Jul 11, 2012 14:00, sampling point TF102 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 1.4 pci/l , sample collected Jul 10, 2012 13:00, sampling point TF101 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| 0.6 pci/l , sample collected Jul 10, 2012 13:00, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.201 pci/l Minimum Reporting Level , sample collected Jul 10, 2012 13:00, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| 0.6 pci/l , sample collected Jul 10, 2012 13:00, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 1.7 pci/l , sample collected Jul 10, 2012 13:30, sampling point TF102 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Jul 10, 2012 13:30, sampling point TF102 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Jul 10, 2012 13:30, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| Not detected below 0.39 pci/l Minimum Reporting Level , sample collected Jul 10, 2012 13:30, sampling point TF102 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 10, 2012 13:30, sampling point TF102 | Combined Uranium 4006 EPA method 200.8 | Jul 1, 2012 – Sep 30, 2012 |
-
- Collected
- Jan 23, 2013 01:40
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 130124-104NI
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jan 23, 2013 01:10
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 130124-103NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2013 – Dec 31, 2013
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.18 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- 0.16 mg/l
-
- Collected
- Jan 23, 2013 01:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 130124-102NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2013 – Dec 31, 2013
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- 0.02 mg/l
-
- Collected
- Nov 5, 2012 02:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 121106-011NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2012 – Dec 31, 2012
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.2 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- 0.14 mg/l
-
- Collected
- Sep 11, 2012 09:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 201209120607
- Laboratory
- Eurofins Eaton Analytical
- Monitoring period
- Jan 1, 2011 – Dec 31, 2019
-
Asbestos 1094 EPA method 100.2
- Result
- Not detected below 6.1 mfl Minimum Reporting Level
-
- Collected
- Jul 11, 2012 13:40
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 201211120266
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.4 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- 0.6 pci/l
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.201 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- 0.6 pci/l
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Jul 11, 2012 14:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201211120264
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.7 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.39 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Jul 10, 2012 13:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120711-015
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.4 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- 0.6 pci/l
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.201 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- 0.6 pci/l
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Jul 10, 2012 13:30
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120711-016
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.7 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.39 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Jul 10, 2012 13:30
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120711-016RU
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
Routine (10).