This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0100016 , Pan Handle W/A #2
25 of the 59 analytes this system has been tested for have been detected at least once, across 161 samples on record.
The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 161 samples on record, detections range from September 29, 1993 to September 16, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 75 of 76 results | Sep 29, 1993 | Sep 16, 2025 |
| Lead 1030 | Inorganic Chemical | 50 of 76 results | Sep 29, 1993 | Sep 16, 2025 |
| Barium 1010 | Inorganic Chemical | 11 of 11 results | Mar 12, 2002 | Jan 15, 2025 |
| TTHM 2950 | Organic Chemical | 10 of 16 results | Jul 10, 2007 | May 14, 2025 |
| Bromodichloromethane 2943 | Organic Chemical | 7 of 12 results | Aug 18, 2014 | May 14, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 7 of 12 results | Jul 10, 2007 | May 14, 2025 |
| Chromium 1020 | Inorganic Chemical | 6 of 11 results | Mar 12, 2002 | Jan 15, 2025 |
| Bromoform 2942 | Organic Chemical | 5 of 12 results | Jul 10, 2007 | May 14, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 5 of 16 results | Jul 10, 2007 | Feb 18, 2025 |
| Chloroform 2941 | Organic Chemical | 4 of 12 results | Aug 18, 2014 | May 14, 2025 |
| Nickel 1036 | Inorganic Chemical | 4 of 11 results | Feb 14, 2005 | Apr 7, 2020 |
| Sodium 1052 | Inorganic Chemical | 3 of 3 results | Sep 23, 2019 | Oct 14, 2024 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 3 of 23 results | Jan 27, 2014 | Jan 17, 2023 |
| Nitrate 1040 | Inorganic Chemical | 3 of 23 results | Jan 27, 2014 | Jan 17, 2023 |
| Dichloroacetic Acid 2451 | Organic Chemical | 2 of 12 results | Aug 18, 2014 | Jul 18, 2018 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 2 of 4 results | Jun 27, 2012 | Sep 12, 2012 |
| Cadmium 1015 | Inorganic Chemical | 2 of 11 results | Feb 14, 2005 | Jan 23, 2006 |
| Selenium 1045 | Inorganic Chemical | 2 of 11 results | Feb 14, 2005 | Jan 23, 2006 |
| Sulfate 1055 | Inorganic Chemical | 2 of 2 results | Mar 12, 2002 | Jan 14, 2004 |
| Cyanide 1024 | Inorganic Chemical | 1 of 10 results | Apr 14, 2021 | Apr 14, 2021 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 1 of 1 result | Jul 6, 2020 | Jul 6, 2020 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 1 of 3 results | Jul 6, 2020 | Jul 6, 2020 |
| Radium-228 4030 | Radionuclide | 1 of 3 results | Jul 6, 2020 | Jul 6, 2020 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 12 results | Aug 12, 2008 | Aug 12, 2008 |
| Fluoride 1025 | Inorganic Chemical | 1 of 11 results | Mar 24, 2008 | Mar 24, 2008 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 121–130 of 161 samples, newest first — collected September 18, 2000 to April 5, 2004. The summary above covers all 161.
76 results from the 10 samples listed here: 13 detected, 63 not detected. Across the whole record it is 209 of 664. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,2,4-Trichlorobenzene 2378 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Cis-1,2-Dichloroethylene 2380 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Xylenes, Total 2955 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Dichloromethane 2964 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | O-Dichlorobenzene 2968 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | P-Dichlorobenzene 2969 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Vinyl Chloride 2976 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,1-Dichloroethylene 2977 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Trans-1,2-Dichloroethylene 2979 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,2-Dichloroethane 2980 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,1,1-Trichloroethane 2981 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Carbon Tetrachloride 2982 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,2-Dichloropropane 2983 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Trichloroethylene 2984 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | 1,1,2-Trichloroethane 2985 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Tetrachloroethylene 2987 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Chlorobenzene 2989 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Benzene 2990 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Toluene 2991 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Ethylbenzene 2992 | Apr 1, 2004 – Jun 30, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Apr 5, 2004, sampling point TF101 | Styrene 2996 | Apr 1, 2004 – Jun 30, 2004 |
|
||
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Arsenic 1005 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| 0.036 mg/l , sample collected Jan 14, 2004, sampling point TF101 | Barium 1010 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Cadmium 1015 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Fluoride 1025 EPA method 300.0 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Mercury 1035 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Selenium 1045 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| 3.35 mg/l , sample collected Jan 14, 2004, sampling point TF101 | Sulfate 1055 EPA method 300.0 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.0003 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2002 – Dec 31, 2004 |
|
||
| Not detected below 0.01 mg/l Minimum Reporting Level , sample collected Jan 14, 2004, sampling point TF101 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2002 – Dec 31, 2004 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,2,4-Trichlorobenzene 2378 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Cis-1,2-Dichloroethylene 2380 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Xylenes, Total 2955 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Dichloromethane 2964 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | O-Dichlorobenzene 2968 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | P-Dichlorobenzene 2969 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Vinyl Chloride 2976 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,1-Dichloroethylene 2977 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Trans-1,2-Dichloroethylene 2979 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,2-Dichloroethane 2980 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,1,1-Trichloroethane 2981 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Carbon Tetrachloride 2982 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,2-Dichloropropane 2983 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Trichloroethylene 2984 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | 1,1,2-Trichloroethane 2985 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Tetrachloroethylene 2987 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Chlorobenzene 2989 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Benzene 2990 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Toluene 2991 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Ethylbenzene 2992 | Jan 1, 2004 – Mar 31, 2004 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jan 6, 2004, sampling point TF101 | Styrene 2996 | Jan 1, 2004 – Mar 31, 2004 |
|
||
| Not detected below 0.01 mg/l Minimum Reporting Level , sample collected Mar 26, 2002, sampling point TF101 | Cyanide 1024 EPA method 335.4 | Jan 1, 2002 – Dec 31, 2004 |
|
||
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Arsenic 1005 EPA method 200.8 | Not recorded |
| 0.032 mg/l , sample collected Mar 12, 2002, sampling point TF101 | Barium 1010 EPA method 200.8 | Not recorded |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Cadmium 1015 EPA method 200.8 | Not recorded |
| 0.003 mg/l , sample collected Mar 12, 2002, sampling point TF101 | Chromium 1020 EPA method 200.8 | Not recorded |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Fluoride 1025 EPA method 300.0 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Mercury 1035 EPA method 200.8 | Not recorded |
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Selenium 1045 EPA method 200.8 | Not recorded |
| 2.79 mg/l , sample collected Mar 12, 2002, sampling point TF101 | Sulfate 1055 EPA method 300.0 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Antimony, Total 1074 EPA method 200.8 | Not recorded |
| Not detected below 0.0003 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Beryllium, Total 1075 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 12, 2002, sampling point TF101 | Thallium, Total 1085 EPA method 200.8 | Not recorded |
|
||
| 0.071 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Copper, Free 1022 | Not recorded |
| 0.003 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Lead 1030 | Not recorded |
|
||
| 0.362 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Copper, Free 1022 | Not recorded |
| 0.002 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Lead 1030 | Not recorded |
|
||
| 0.307 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Copper, Free 1022 | Not recorded |
| 0.003 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Lead 1030 | Not recorded |
|
||
| 0.3 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Copper, Free 1022 | Not recorded |
| 0.002 mg/l , sample collected Sep 18, 2000, sampling point DS000 | Lead 1030 | Not recorded |
-
- Collected
- Apr 5, 2004
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 040406-038VO
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2004 – Jun 30, 2004
-
1,2,4-Trichlorobenzene 2378
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Cis-1,2-Dichloroethylene 2380
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Xylenes, Total 2955
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Dichloromethane 2964
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
O-Dichlorobenzene 2968
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
P-Dichlorobenzene 2969
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Vinyl Chloride 2976
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1-Dichloroethylene 2977
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trans-1,2-Dichloroethylene 2979
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloroethane 2980
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,1-Trichloroethane 2981
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Carbon Tetrachloride 2982
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloropropane 2983
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trichloroethylene 2984
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,2-Trichloroethane 2985
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Tetrachloroethylene 2987
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Chlorobenzene 2989
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Benzene 2990
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Toluene 2991
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Ethylbenzene 2992
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Styrene 2996
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Jan 14, 2004
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 040115-026IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Barium 1010 EPA method 200.8
- Result
- 0.036 mg/l
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Fluoride 1025 EPA method 300.0
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Sulfate 1055 EPA method 300.0
- Result
- 3.35 mg/l
- Monitoring period
- Not recorded
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0003 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
- Collected
- Jan 14, 2004
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 040115-020CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.01 mg/l Minimum Reporting Level
-
- Collected
- Jan 6, 2004
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 040107-011VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2004 – Mar 31, 2004
-
1,2,4-Trichlorobenzene 2378
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Cis-1,2-Dichloroethylene 2380
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Xylenes, Total 2955
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Dichloromethane 2964
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
O-Dichlorobenzene 2968
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
P-Dichlorobenzene 2969
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Vinyl Chloride 2976
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1-Dichloroethylene 2977
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trans-1,2-Dichloroethylene 2979
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloroethane 2980
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,1-Trichloroethane 2981
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Carbon Tetrachloride 2982
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloropropane 2983
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trichloroethylene 2984
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,2-Trichloroethane 2985
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Tetrachloroethylene 2987
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Chlorobenzene 2989
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Benzene 2990
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Toluene 2991
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Ethylbenzene 2992
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Styrene 2996
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Mar 26, 2002
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 020327-027CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2002 – Dec 31, 2004
-
Cyanide 1024 EPA method 335.4
- Result
- Not detected below 0.01 mg/l Minimum Reporting Level
-
- Collected
- Mar 12, 2002
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 020313-019IN
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
-
Barium 1010 EPA method 200.8
- Result
- 0.032 mg/l
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
-
Chromium 1020 EPA method 200.8
- Result
- 0.003 mg/l
-
Fluoride 1025 EPA method 300.0
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
-
Sulfate 1055 EPA method 300.0
- Result
- 2.79 mg/l
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0003 mg/l Minimum Reporting Level
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Sep 18, 2000
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 000920-059L
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Copper, Free 1022
- Result
- 0.071 mg/l
-
Lead 1030
- Result
- 0.003 mg/l
-
- Collected
- Sep 18, 2000
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 000920-058L
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Copper, Free 1022
- Result
- 0.362 mg/l
-
Lead 1030
- Result
- 0.002 mg/l
-
- Collected
- Sep 18, 2000
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 000920-057L
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Copper, Free 1022
- Result
- 0.307 mg/l
-
Lead 1030
- Result
- 0.003 mg/l
-
- Collected
- Sep 18, 2000
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 000920-056L
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Copper, Free 1022
- Result
- 0.3 mg/l
-
Lead 1030
- Result
- 0.002 mg/l
Routine (10).