Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Radium-226 results

MS0120027 , Wautubbee Water Assn

8 samples have been analysed for Radium-226 at Wautubbee Water Assn.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Radium-226 result

All 8 samples analysed for this analyte are listed below, newest first. No date range is applied.

8 Radium-226 results from the 8 samples listed here: 1 detected, 7 not detected. Those samples also carried 21 results for other analytes, which are on the full results page.

Radium-226 results for Wautubbee Water Assn, from the 8 samples analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Dec 14, 2015 09:30
Sampling point
TF102 Treatment Facility TF102
Sample type
Routine
Lab sample
201512210048
Laboratory
Radiation Safety Engineering
0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Dec 14, 2015 09:30, sampling point TF102 Radium-226 4020 EPA method 903.1 Oct 1, 2015 – Dec 31, 2015
Collected
Aug 4, 2015 09:50
Sampling point
TF102 Treatment Facility TF102
Sample type
Routine
Lab sample
201508110060
Laboratory
Radiation Safety Engineering
Not detected below 0.261 pci/l Minimum Reporting Level , sample collected Aug 4, 2015 09:50, sampling point TF102 Radium-226 4020 EPA method 903.1 Jul 1, 2015 – Sep 30, 2015
Collected
May 28, 2014 15:40
Sampling point
TF102 Treatment Facility TF102
Sample type
Routine
Lab sample
201408280496
Laboratory
Radiation Safety Engineering
Not detected below 0.256 pci/l Minimum Reporting Level , sample collected May 28, 2014 15:40, sampling point TF102 Radium-226 4020 EPA method 903.1 Apr 1, 2014 – Jun 30, 2014
Collected
Jul 10, 2012 15:40
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201211120014
Laboratory
Radiation Safety Engineering
Not detected below 0.333 pci/l Minimum Reporting Level , sample collected Jul 10, 2012 15:40, sampling point TF101 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 9, 2012 15:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120710-022
Laboratory
Radiation Safety Engineering
Not detected below 0.333 pci/l Minimum Reporting Level , sample collected Jul 9, 2012 15:30, sampling point TF101 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
Collected
Apr 17, 2012 15:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120418-033
Laboratory
Radiation Safety Engineering
Not detected below 0.333 pci/l Minimum Reporting Level , sample collected Apr 17, 2012 15:30, sampling point TF101 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Collected
Feb 13, 2012 15:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120214-036
Laboratory
Radiation Safety Engineering
Not detected below 0.333 pci/l Minimum Reporting Level , sample collected Feb 13, 2012 15:30, sampling point TF101 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Collected
Dec 5, 2011 03:40
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
111206-004
Laboratory
Radiation Safety Engineering
Not detected below 0.333 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 03:40, sampling point TF101 Radium-226 4020 EPA method 903.1 Oct 1, 2011 – Dec 31, 2011

Routine (8).