Chromium results
MS0140004 , Town of Friars Point
19 samples have been analysed for Chromium at Town of Friars Point.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Chromium result
The table below lists 1–10 of 19 samples, newest first — collected April 16, 2008 to February 26, 2024.
10 Chromium results from the 10 samples listed here: 5 detected, 5 not detected. Those samples also carried 100 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 26, 2024 17:00, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2023 – Dec 31, 2025 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 26, 2024 17:00, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2023 – Dec 31, 2025 |
|
||
| 0.005 mg/l , sample collected Sep 26, 2018 01:45, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Sep 26, 2018 01:56, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
|
||
| 0.0035 mg/l , sample collected Apr 21, 2014 01:00, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
|
||
| 0.0049 mg/l , sample collected Apr 21, 2014 01:00, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
|
||
| 0.001689 mg/l , sample collected Jul 25, 2011 01:15, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 25, 2011 01:40, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| 0.000977 mg/l , sample collected Apr 16, 2008, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 16, 2008, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
-
- Collected
- Feb 26, 2024 17:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- IN-240228-004
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2023 – Dec 31, 2025
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Feb 26, 2024 17:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- IN-240228-003
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2023 – Dec 31, 2025
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Sep 26, 2018 01:45
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 180928-005IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Chromium 1020 EPA method 200.8
- Result
- 0.005 mg/l
-
- Collected
- Sep 26, 2018 01:56
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 180928-003IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Apr 21, 2014 01:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 140422-056IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Chromium 1020 EPA method 200.8
- Result
- 0.0035 mg/l
-
- Collected
- Apr 21, 2014 01:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 140422-045IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Chromium 1020 EPA method 200.8
- Result
- 0.0049 mg/l
-
- Collected
- Jul 25, 2011 01:15
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 110726-028IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Chromium 1020 EPA method 200.8
- Result
- 0.001689 mg/l
-
- Collected
- Jul 25, 2011 01:40
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 110726-027IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Apr 16, 2008
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 080417-046IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Chromium 1020 EPA method 200.8
- Result
- 0.000977 mg/l
-
- Collected
- Apr 16, 2008
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 080417-045IN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
Routine (10).