Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Lead and copper

MS0160004 , North Covington W/A-North

Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.

Lead and copper 90th-percentile sample summaries for North Covington W/A-North, 40 summaries, every one on record. The agency records no date of receipt for any of them.
Analyte Monitoring period Samples 90th percentile Facility Data quality
Copper Jan 1, 2025 – Dec 31, 2025 10 0.524 mg/l DS000 Accepted
Lead Jan 1, 2025 – Dec 31, 2025 10 0.001 mg/l DS000 Accepted
Copper Jan 1, 2024 – Dec 31, 2024 10 0.408 mg/l DS000 Accepted
Lead Jan 1, 2024 – Dec 31, 2024 10 0.0005 mg/l DS000 Accepted
Copper Jan 1, 2023 – Dec 31, 2023 10 0.0949 mg/l DS000 Accepted
Lead Jan 1, 2023 – Dec 31, 2023 10 0.0006 mg/l DS000 Accepted
Copper Jan 1, 2022 – Dec 31, 2022 10 0.0046 mg/l DS000 Accepted
Lead Jan 1, 2022 – Dec 31, 2022 10 0.0005 mg/l DS000 Accepted
Copper Jul 1, 2021 – Dec 31, 2021 20 0.102 mg/l DS000 Accepted
Lead Jul 1, 2021 – Dec 31, 2021 20 0.0006 mg/l DS000 Accepted
Copper Jan 1, 2021 – Jun 30, 2021 20 0.369 mg/l DS000 Accepted
Lead Jan 1, 2021 – Jun 30, 2021 20 0.0016 mg/l DS000 Accepted
Copper Jan 1, 2020 – Jun 30, 2020 20 0.2131 mg/l DS000 Accepted
Lead Jan 1, 2020 – Jun 30, 2020 20 0.0013 mg/l DS000 Accepted
Copper Jan 1, 2018 – Dec 31, 2020 10 1.6951 mg/l DS000 Accepted
Lead Jan 1, 2018 – Dec 31, 2020 10 0.0106 mg/l DS000 Accepted
Copper Jan 1, 2017 – Dec 31, 2019 10 1.6951 mg/l DS000 Accepted
Lead Jan 1, 2017 – Dec 31, 2019 10 0.0106 mg/l DS000 Accepted
Copper Jan 1, 2015 – Dec 31, 2017 10 1.0319 mg/l DS000 Accepted
Lead Jan 1, 2015 – Dec 31, 2017 10 0.0065 mg/l DS000 Accepted
Copper Jan 1, 2014 – Dec 31, 2016 21 0.942 mg/l DS000 Accepted
Lead Jan 1, 2014 – Dec 31, 2016 21 0.0112 mg/l DS000 Accepted
Copper Jan 1, 2012 – Dec 31, 2014 11 0.4115 mg/l DS000 Accepted
Lead Jan 1, 2012 – Dec 31, 2014 11 0.011 mg/l DS000 Accepted
Copper Jan 1, 2011 – Dec 31, 2013 10 0.0453 mg/l DS000 Accepted
Lead Jan 1, 2011 – Dec 31, 2013 10 0.0005 mg/l DS000 Accepted
Copper Jan 1, 2009 – Dec 31, 2011 10 0.0453 mg/l DS000 Accepted
Lead Jan 1, 2009 – Dec 31, 2011 10 0.0005 mg/l DS000 Accepted
Copper Jan 1, 2006 – Dec 31, 2008 10 0.9153 mg/l DS000 Accepted
Lead Jan 1, 2006 – Dec 31, 2008 10 0.0015 mg/l DS000 Accepted
Copper Jan 1, 2000 – Dec 31, 2002 10 0.022 mg/l DS000 Accepted
Lead Jan 1, 2000 – Dec 31, 2002 10 0.013 mg/l DS000 Accepted
Copper Jan 1, 1996 – Dec 31, 1996 10 0 mg/l DS000 Accepted
Lead Jan 1, 1996 – Dec 31, 1996 10 0.003 mg/l DS000 Accepted
Copper Jan 1, 1995 – Dec 31, 1995 10 0.266 mg/l DS000 Accepted
Lead Jan 1, 1995 – Dec 31, 1995 10 0.001 mg/l DS000 Accepted
Copper Jan 1, 1994 – Jun 30, 1994 21 0 mg/l DS000 Accepted
Lead Jan 1, 1994 – Jun 30, 1994 21 0.001 mg/l DS000 Accepted
Copper Jul 1, 1993 – Dec 31, 1993 21 0 mg/l DS000 Accepted
Lead Jul 1, 1993 – Dec 31, 1993 21 0 mg/l DS000 Accepted

No date of receipt is recorded for any of these summaries.

This system’s violations

What the 90th percentile is

The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.