Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0160011 , North Covington W/A-South

18 of the 58 analytes this system has been tested for have been detected at least once, across 290 samples on record.

The other 40 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 290 samples on record, detections range from July 13, 1993 to September 25, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for North Covington W/A-South, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 92 of 141 results Jul 13, 1993 Sep 25, 2025
Lead 1030 Inorganic Chemical 84 of 141 results Jul 13, 1993 Sep 25, 2025
Nitrate-Nitrite 1038 Inorganic Chemical 33 of 34 results May 3, 2004 Feb 5, 2025
Nitrate 1040 Inorganic Chemical 33 of 34 results May 3, 2004 Feb 5, 2025
Barium 1010 Inorganic Chemical 17 of 17 results Apr 16, 2002 Feb 5, 2025
Sodium 1052 Inorganic Chemical 6 of 6 results Sep 16, 2019 Oct 16, 2024
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 5 of 22 results Jul 9, 2007 Sep 1, 2021
Nickel 1036 Inorganic Chemical 4 of 17 results Jan 25, 2006 Apr 16, 2014
Xylenes, Total 2955 Organic Chemical 3 of 26 results Oct 14, 2004 Jun 12, 2019
TTHM 2950 Organic Chemical 2 of 22 results Jul 9, 2007 Sep 23, 2008
Dichloroacetic Acid 2451 Organic Chemical 1 of 15 results Jul 29, 2020 Jul 29, 2020
Monochloroacetic Acid 2450 Organic Chemical 1 of 15 results Jul 25, 2018 Jul 25, 2018
Gross Alpha, Incl. Radon & U 4002 Radionuclide 1 of 6 results May 27, 2014 May 27, 2014
Cadmium 1015 Inorganic Chemical 1 of 17 results Jan 25, 2006 Jan 25, 2006
Chromium 1020 Inorganic Chemical 1 of 17 results Jan 25, 2006 Jan 25, 2006
Selenium 1045 Inorganic Chemical 1 of 17 results Jan 25, 2006 Jan 25, 2006
Fluoride 1025 Inorganic Chemical 1 of 17 results Apr 16, 2002 Apr 16, 2002
Sulfate 1055 Inorganic Chemical 1 of 3 results Apr 16, 2002 Apr 16, 2002

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 171–180 of 290 samples, newest first — collected May 12, 2008 to July 14, 2011. The summary above covers all 290.

78 results from the 10 samples listed here: 13 detected, 65 not detected. Across the whole record it is 287 of 1,363. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for North Covington W/A-South, every result from 171 to 180 of 290 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jul 14, 2011
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
110715-021PB
Laboratory
MSDH Lab
0.26 mg/l , sample collected Jul 14, 2011, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2009 – Dec 31, 2011
0.0013 mg/l , sample collected Jul 14, 2011, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2009 – Dec 31, 2011
Collected
May 11, 2011
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
110512-047IN
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Arsenic 1005 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.0166 mg/l , sample collected May 11, 2011, sampling point TF080 Barium 1010 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Cadmium 1015 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Chromium 1020 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Fluoride 1025 EPA method 380-75WE Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Mercury 1035 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Nickel 1036 EPA method 200.8 Not recorded
Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Selenium 1045 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Antimony, Total 1074 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Beryllium, Total 1075 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2011, sampling point TF080 Thallium, Total 1085 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Collected
Jan 26, 2011
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
110127-022NI
Laboratory
MSDH Lab
0.55 mg/l , sample collected Jan 26, 2011, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
0.55 mg/l , sample collected Jan 26, 2011, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 26, 2011, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2011 – Dec 31, 2011
Collected
May 26, 2010
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
100527-045NI
Laboratory
MSDH Lab
0.53 mg/l , sample collected May 26, 2010, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
0.53 mg/l , sample collected May 26, 2010, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
Not detected below 0.05 mg/l Minimum Reporting Level , sample collected May 26, 2010, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2010 – Dec 31, 2010
Collected
Jun 17, 2009
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
090618-004VO
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,2,4-Trichlorobenzene 2378 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Cis-1,2-Dichloroethylene 2380 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Xylenes, Total 2955 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Dichloromethane 2964 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 O-Dichlorobenzene 2968 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 P-Dichlorobenzene 2969 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Vinyl Chloride 2976 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,1-Dichloroethylene 2977 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Trans-1,2-Dichloroethylene 2979 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,2-Dichloroethane 2980 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,1,1-Trichloroethane 2981 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Carbon Tetrachloride 2982 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,2-Dichloropropane 2983 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Trichloroethylene 2984 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 1,1,2-Trichloroethane 2985 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Tetrachloroethylene 2987 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Chlorobenzene 2989 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Benzene 2990 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Toluene 2991 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Ethylbenzene 2992 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 17, 2009, sampling point TF080 Styrene 2996 EPA method 524.2 Jan 1, 2009 – Dec 31, 2009
Collected
Apr 6, 2009
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
090407-009NI
Laboratory
MSDH Lab
0.54 mg/l , sample collected Apr 6, 2009, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2009 – Dec 31, 2009
0.54 mg/l , sample collected Apr 6, 2009, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2009 – Dec 31, 2009
Not detected below 0.05 mg/l Minimum Reporting Level , sample collected Apr 6, 2009, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2009 – Dec 31, 2009
Collected
Sep 23, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080924-002HA
Laboratory
MSDH Lab
Not detected below 0.002 mg/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Monochloroacetic Acid 2450 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Dichloroacetic Acid 2451 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Trichloroacetic Acid 2452 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Monobromoacetic Acid 2453 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Dibromoacetic Acid 2454 EPA method 552.2 Not recorded
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 23, 2008, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2008 – Dec 31, 2010
Collected
Sep 23, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080924-002TH
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Chloroform 2941 EPA method 524.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Bromoform 2942 EPA method 524.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Bromodichloromethane 2943 EPA method 524.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 23, 2008, sampling point MRT000 Dibromochloromethane 2944 EPA method 524.2 Not recorded
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 23, 2008, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2008 – Dec 31, 2010
Collected
Aug 25, 2008
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
080826-020VO
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,2,4-Trichlorobenzene 2378 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Cis-1,2-Dichloroethylene 2380 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Xylenes, Total 2955 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Dichloromethane 2964 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 O-Dichlorobenzene 2968 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 P-Dichlorobenzene 2969 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Vinyl Chloride 2976 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,1-Dichloroethylene 2977 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Trans-1,2-Dichloroethylene 2979 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,2-Dichloroethane 2980 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,1,1-Trichloroethane 2981 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Carbon Tetrachloride 2982 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,2-Dichloropropane 2983 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Trichloroethylene 2984 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 1,1,2-Trichloroethane 2985 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Tetrachloroethylene 2987 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Chlorobenzene 2989 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Benzene 2990 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Toluene 2991 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Ethylbenzene 2992 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 25, 2008, sampling point TF080 Styrene 2996 EPA method 524.2 Jan 1, 2008 – Dec 31, 2008
Collected
May 12, 2008
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
080513-081NI
Laboratory
MSDH Lab
0.47 mg/l , sample collected May 12, 2008, sampling point TF080 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2008 – Dec 31, 2008
0.47 mg/l , sample collected May 12, 2008, sampling point TF080 Nitrate 1040 EPA method 353.2 Jan 1, 2008 – Dec 31, 2008
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected May 12, 2008, sampling point TF080 Nitrite 1041 EPA method 353.2 Jan 1, 2008 – Dec 31, 2008

Routine (10).