Lead and copper
MS0160012 , Sanderson Farms LLC
Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.
| Analyte | Monitoring period | Samples | 90th percentile | Facility | Data quality |
|---|---|---|---|---|---|
| Copper | Jan 1, 2023 – Dec 31, 2025 | 10 | 0.0825 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2023 – Dec 31, 2025 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2020 – Dec 31, 2022 | 10 | 0.0484 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2020 – Dec 31, 2022 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2017 – Dec 31, 2019 | 10 | 0.2076 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2017 – Dec 31, 2019 | 10 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2015 – Dec 31, 2017 | 10 | 0.2223 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2015 – Dec 31, 2017 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2012 – Dec 31, 2014 | 10 | 0.0885 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2012 – Dec 31, 2014 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2009 – Dec 31, 2011 | 10 | 0.1047 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2009 – Dec 31, 2011 | 10 | 0.0008 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2006 – Dec 31, 2008 | 20 | 0.284 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2006 – Dec 31, 2008 | 20 | 0.0016 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2003 – Dec 31, 2005 | 10 | 0.2376 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2003 – Dec 31, 2005 | 10 | 0.0033 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2000 – Dec 31, 2000 | 10 | 0.015 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2000 – Dec 31, 2000 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.117 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.005 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1995 – Dec 31, 1995 | 10 | 0.313 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1995 – Dec 31, 1995 | 10 | 0.006 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1994 – Dec 31, 1994 | 20 | 0.531 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1994 – Dec 31, 1994 | 20 | 0.006 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1994 – Jun 30, 1994 | 32 | 0.682 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1994 – Jun 30, 1994 | 32 | 0.005 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1993 – Dec 31, 1993 | 20 | 0.533 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1993 – Dec 31, 1993 | 20 | 0.019 mg/l | DS000 | Accepted |
No date of receipt is recorded for any of these summaries.
What the 90th percentile is
The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.
From the help text published with these pages.