Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Radium-226 results

MS0170002 , City of Hernando-Jaybird

8 samples have been analysed for Radium-226 at City of Hernando-Jaybird.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Radium-226 result

All 8 samples analysed for this analyte are listed below, newest first. No date range is applied.

8 Radium-226 results from the 8 samples listed here: 1 detected, 7 not detected. Those samples also carried 27 results for other analytes, which are on the full results page.

Radium-226 results for City of Hernando-Jaybird, from the 8 samples analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jul 15, 2020 14:45
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
4674742
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Jul 15, 2020 14:45, sampling point TF081 Radium-226 4020 EPA method 7500-RAB Jan 1, 2012 – Dec 31, 2020
Collected
Oct 4, 2012 13:50
Sampling point
TF082 Treatment Facility TF082
Sample type
Routine
Lab sample
201301120249
Laboratory
Radiation Safety Engineering
Not detected below 0.228 pci/l Minimum Reporting Level , sample collected Oct 4, 2012 13:50, sampling point TF082 Radium-226 4020 EPA method 903.1 Oct 1, 2012 – Dec 31, 2012
Collected
Oct 3, 2012 14:00
Sampling point
TF082 Treatment Facility TF082
Sample type
Routine
Lab sample
121004-116
Laboratory
Radiation Safety Engineering
Not detected below 0.228 pci/l Minimum Reporting Level , sample collected Oct 3, 2012 14:00, sampling point TF082 Radium-226 4020 EPA method 903.1 Oct 1, 2012 – Dec 31, 2012
Collected
Jul 30, 2012 15:20
Sampling point
TF082 Treatment Facility TF082
Sample type
Routine
Lab sample
120731-165
Laboratory
Radiation Safety Engineering
Not detected below 0.228 pci/l Minimum Reporting Level , sample collected Jul 30, 2012 15:20, sampling point TF082 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
Collected
May 14, 2012 14:30
Sampling point
TF082 Treatment Facility TF082
Sample type
Routine
Lab sample
120515-176
Laboratory
Radiation Safety Engineering
Not detected below 0.228 pci/l Minimum Reporting Level , sample collected May 14, 2012 14:30, sampling point TF082 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Collected
Mar 5, 2012 13:50
Sampling point
TF082 Treatment Facility TF082
Sample type
Routine
Lab sample
120306-173
Laboratory
Radiation Safety Engineering
Not detected below 0.228 pci/l Minimum Reporting Level , sample collected Mar 5, 2012 13:50, sampling point TF082 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Collected
Nov 30, 2011 14:30
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
291409008
Laboratory
Gel Laboratories
0.761 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Nov 30, 2011 14:30, sampling point TF081 Radium-226 4020 EPA method 903.1 Oct 1, 2011 – Dec 31, 2011
Collected
Sep 26, 2011 15:30
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
286822014
Laboratory
Gel Laboratories
Not detected below 0.532 pci/l Minimum Reporting Level , sample collected Sep 26, 2011 15:30, sampling point TF081 Radium-226 4020 EPA method 903.1 Jul 1, 2011 – Sep 30, 2011

Routine (8).