This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Radium-228 results
MS0170018 , City of Southaven
21 samples have been analysed for Radium-228 at City of Southaven.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Radium-228 result
The table below lists 11–20 of 21 samples, newest first — collected December 19, 2008 to March 6, 2012.
10 Radium-228 results from the 10 samples listed here: 4 detected, 6 not detected. Those samples also carried 49 results for other analytes, which are on the full results page.
Units in this table
Radium-228 is recorded on this page in ug/l, mg/l and pci/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.26 pci/l Minimum Reporting Level , sample collected Mar 6, 2012 15:37, sampling point TF084 | Radium-228 4030 EPA method 904.0 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| 0.02 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Feb 22, 2010, sampling point TF084 | Radium-228 4030 EPA method 904 | Jan 1, 2010 – Mar 31, 2010 |
|
||
| 0.183 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Radium-228 4030 EPA method 904 | Jul 1, 2009 – Sep 30, 2009 |
|
||
| 1.55 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Feb 24, 2009, sampling point TF084 | Radium-228 4030 EPA method 904 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 24, 2009, sampling point TF083 | Radium-228 4030 EPA method 904 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 24, 2009, sampling point TF081 | Radium-228 4030 EPA method 904 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 24, 2009, sampling point TF080 | Radium-228 4030 EPA method 904 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| 1.17 pci/l , sample collected Dec 19, 2008, sampling point TF084 | Radium-228 4030 EPA method 904 | Oct 1, 2008 – Dec 31, 2008 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Dec 19, 2008, sampling point TF083 | Radium-228 4030 EPA method 904 | Oct 1, 2008 – Dec 31, 2008 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Dec 19, 2008, sampling point TF081 | Radium-228 4030 EPA method 904 | Oct 1, 2008 – Dec 31, 2008 |
-
- Collected
- Mar 6, 2012 15:37
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 120307-096
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.26 pci/l Minimum Reporting Level
-
- Collected
- Feb 22, 2010
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 00314-001
- Laboratory
- Laboratory, Ars
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
Radium-228 4030 EPA method 904
- Result
- 0.02 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Sep 21, 2009
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 02396-001
- Laboratory
- Laboratory, Ars
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
-
Radium-228 4030 EPA method 904
- Result
- 0.183 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Feb 24, 2009
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 225288064
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-228 4030 EPA method 904
- Result
- 1.55 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Feb 24, 2009
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- 225288063
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 24, 2009
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 225288062
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 24, 2009
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 225288061
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Dec 19, 2008
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 222167032
- Laboratory
- Gel Laboratories
- Monitoring period
- Oct 1, 2008 – Dec 31, 2008
-
Radium-228 4030 EPA method 904
- Result
- 1.17 pci/l
-
- Collected
- Dec 19, 2008
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- 222167031
- Laboratory
- Gel Laboratories
- Monitoring period
- Oct 1, 2008 – Dec 31, 2008
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Dec 19, 2008
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 222167030
- Laboratory
- Gel Laboratories
- Monitoring period
- Oct 1, 2008 – Dec 31, 2008
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 1 pci/l Minimum Reporting Level
Routine (10).