Chemical and radiological sample results
MS0170018 , City of Southaven
30 of the 60 analytes this system has been tested for have been detected at least once, across 839 samples on record.
The other 30 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 839 samples on record, detections range from July 20, 1992 to June 22, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 424 of 451 results | Jul 20, 1992 | Jun 12, 2024 |
| Lead 1030 | Inorganic Chemical | 170 of 451 results | Jul 20, 1992 | Jun 11, 2024 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 64 of 96 results | May 5, 2004 | Feb 9, 2026 |
| Nitrate 1040 | Inorganic Chemical | 64 of 96 results | May 5, 2004 | Feb 9, 2026 |
| Fluoride 1025 | Inorganic Chemical | 52 of 53 results | Apr 16, 2002 | Jun 22, 2026 |
| Barium 1010 | Inorganic Chemical | 50 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| Nickel 1036 | Inorganic Chemical | 37 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| TTHM 2950 | Organic Chemical | 26 of 59 results | Mar 9, 2004 | Mar 17, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 22 of 57 results | Apr 14, 2004 | Mar 17, 2025 |
| Chromium 1020 | Inorganic Chemical | 19 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| Bromoform 2942 | Organic Chemical | 19 of 39 results | Jul 24, 2006 | Aug 1, 2017 |
| Dibromochloromethane 2944 | Organic Chemical | 17 of 39 results | Jul 24, 2006 | Jul 19, 2018 |
| Sodium 1052 | Inorganic Chemical | 12 of 12 results | Sep 24, 2019 | Oct 14, 2024 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 10 of 21 results | Dec 19, 2008 | May 13, 2019 |
| Radium-228 4030 | Radionuclide | 10 of 21 results | Dec 19, 2008 | May 13, 2019 |
| Selenium 1045 | Inorganic Chemical | 10 of 50 results | Apr 16, 2002 | Mar 31, 2008 |
| Radium-226 4020 | Radionuclide | 7 of 21 results | Sep 21, 2009 | May 13, 2019 |
| Bromodichloromethane 2943 | Organic Chemical | 7 of 39 results | Nov 15, 2006 | Jun 4, 2014 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 6 of 11 results | Mar 6, 2012 | May 13, 2019 |
| Sulfate 1055 | Inorganic Chemical | 6 of 11 results | Sep 10, 2003 | Jan 26, 2004 |
| Cadmium 1015 | Inorganic Chemical | 5 of 50 results | Apr 16, 2002 | Jan 23, 2006 |
| Monochloroacetic Acid 2450 | Organic Chemical | 4 of 33 results | Mar 5, 2014 | Jun 4, 2018 |
| Arsenic 1005 | Inorganic Chemical | 3 of 50 results | Jan 23, 2006 | Jan 23, 2006 |
| Thallium, Total 1085 | Inorganic Chemical | 2 of 50 results | Oct 1, 2018 | May 11, 2022 |
| Dichloroacetic Acid 2451 | Organic Chemical | 1 of 33 results | Sep 4, 2014 | Sep 4, 2014 |
| Gross Alpha, Excl. Radon & U 4000 | Radionuclide | 1 of 10 results | Sep 21, 2009 | Sep 21, 2009 |
| Gross Beta Particle Activity 4100 | Radionuclide | 1 of 1 result | Sep 21, 2009 | Sep 21, 2009 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 1 of 10 results | Sep 21, 2009 | Sep 21, 2009 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 33 results | Jun 30, 2009 | Jun 30, 2009 |
| Chloroform 2941 | Organic Chemical | 1 of 39 results | Nov 15, 2006 | Nov 15, 2006 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 401–410 of 839 samples, newest first — collected September 21, 2009 to January 24, 2011. The summary above covers all 839.
40 results from the 10 samples listed here: 19 detected, 21 not detected. Across the whole record it is 1,052 of 3,017. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
Units in this table
Combined Uranium is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
Gross Alpha Particle Activity is recorded on this page in ug/l and pci/l.
Radium-226 is recorded on this page in ug/l, mg/l and pci/l.
Radium-228 is recorded on this page in ug/l, mg/l and pci/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 24, 2011, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2011 – Dec 31, 2011 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 24, 2011, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2011 – Dec 31, 2011 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 24, 2011, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2011 – Dec 31, 2011 |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Chloroform 2941 EPA method 524.2 | Not recorded |
| 2.93 ug/l , sample collected Aug 17, 2010, sampling point MRT000 | Bromoform 2942 EPA method 524.2 | Not recorded |
| 1.29 ug/l , sample collected Aug 17, 2010, sampling point MRT000 | Bromodichloromethane 2943 EPA method 524.2 | Not recorded |
| 2.89 ug/l , sample collected Aug 17, 2010, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
| Not detected , sample collected Aug 17, 2010, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| Not detected below 0.002 mg/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Monochloroacetic Acid 2450 EPA method 552.2 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Dichloroacetic Acid 2451 EPA method 552.2 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Trichloroacetic Acid 2452 EPA method 552.2 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Monobromoacetic Acid 2453 EPA method 552.2 | Not recorded |
| Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Aug 17, 2010, sampling point MRT000 | Dibromoacetic Acid 2454 EPA method 552.2 | Not recorded |
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Aug 17, 2010, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jun 28, 2010, sampling point TF084 | Combined Uranium 4006 EPA method 200.8 | Apr 1, 2010 – Jun 30, 2010 |
|
||
| Not detected below 0.25 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| Not detected below 0.2 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| 0.26 mg/l , sample collected May 24, 2010, sampling point TF084 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| 0.26 mg/l , sample collected May 24, 2010, sampling point TF084 | Nitrate 1040 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF084 | Nitrite 1041 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| 0.27 mg/l , sample collected May 24, 2010, sampling point TF081 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| 0.27 mg/l , sample collected May 24, 2010, sampling point TF081 | Nitrate 1040 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF081 | Nitrite 1041 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| 0.35 mg/l , sample collected May 24, 2010, sampling point TF083 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| 0.35 mg/l , sample collected May 24, 2010, sampling point TF083 | Nitrate 1040 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected May 24, 2010, sampling point TF083 | Nitrite 1041 EPA method 353.2 | Jan 1, 2010 – Dec 31, 2010 |
|
||
| Not detected below 3 pci/l Minimum Reporting Level , sample collected Feb 22, 2010, sampling point TF084 | Gross Alpha, Excl. Radon & U 4000 | Jan 1, 2010 – Mar 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 22, 2010, sampling point TF084 | Combined Uranium 4006 EPA method 200.8 | Jan 1, 2010 – Mar 31, 2010 |
| 0.394 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Feb 22, 2010, sampling point TF084 | Combined Radium (-226 & -228) 4010 | Not recorded |
| 0.374 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Feb 22, 2010, sampling point TF084 | Radium-226 4020 EPA method 903 | Jan 1, 2010 – Mar 31, 2010 |
| 0.02 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Feb 22, 2010, sampling point TF084 | Radium-228 4030 EPA method 904 | Jan 1, 2010 – Mar 31, 2010 |
| Not detected below 3 pci/l Minimum Reporting Level , sample collected Feb 22, 2010, sampling point TF084 | Gross Alpha Particle Activity 4109 EPA method 900 | Jan 1, 2010 – Mar 31, 2010 |
|
||
| 1.152 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Gross Alpha, Excl. Radon & U 4000 | Jul 1, 2009 – Sep 30, 2009 |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 21, 2009, sampling point TF084 | Combined Uranium 4006 EPA method 200.8 | Jul 1, 2009 – Sep 30, 2009 |
| 0.31 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Combined Radium (-226 & -228) 4010 | Not recorded |
| 0.127 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Radium-226 4020 EPA method 903 | Jul 1, 2009 – Sep 30, 2009 |
| 0.183 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Radium-228 4030 EPA method 904 | Jul 1, 2009 – Sep 30, 2009 |
| 0.925 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Gross Beta Particle Activity 4100 EPA method 900 | Not recorded |
| 1.152 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 21, 2009, sampling point TF084 | Gross Alpha Particle Activity 4109 EPA method 900 | Jul 1, 2009 – Sep 30, 2009 |
-
- Collected
- Jan 24, 2011
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 110125-064NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2011
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Aug 17, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100818-005TH
- Laboratory
- MSDH Lab
-
Chloroform 2941 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Bromoform 2942 EPA method 524.2
- Result
- 2.93 ug/l
- Monitoring period
- Not recorded
-
Bromodichloromethane 2943 EPA method 524.2
- Result
- 1.29 ug/l
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- 2.89 ug/l
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- Not detected
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
- Collected
- Aug 17, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100818-005HA
- Laboratory
- MSDH Lab
-
Monochloroacetic Acid 2450 EPA method 552.2
- Result
- Not detected below 0.002 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Dichloroacetic Acid 2451 EPA method 552.2
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Trichloroacetic Acid 2452 EPA method 552.2
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Monobromoacetic Acid 2453 EPA method 552.2
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Dibromoacetic Acid 2454 EPA method 552.2
- Result
- Not detected below 0.001 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Total Haloacetic Acids (Haa5) 2456
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
- Collected
- Jun 28, 2010
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 100629-004
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2010 – Jun 30, 2010
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- May 24, 2010
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 100525-022NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.25 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.2 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- May 24, 2010
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 100525-005NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.26 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.26 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- May 24, 2010
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 100525-004NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.27 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.27 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- May 24, 2010
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- 100525-003NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2010 – Dec 31, 2010
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.35 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.35 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- Feb 22, 2010
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 00314-001
- Laboratory
- Laboratory, Ars
-
Gross Alpha, Excl. Radon & U 4000
- Result
- Not detected below 3 pci/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
Combined Radium (-226 & -228) 4010
- Result
- 0.394 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903
- Result
- 0.374 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
Radium-228 4030 EPA method 904
- Result
- 0.02 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
Gross Alpha Particle Activity 4109 EPA method 900
- Result
- Not detected below 3 pci/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2010 – Mar 31, 2010
-
- Collected
- Sep 21, 2009
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- 02396-001
- Laboratory
- Laboratory, Ars
-
Gross Alpha, Excl. Radon & U 4000
- Result
- 1.152 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
-
Combined Radium (-226 & -228) 4010
- Result
- 0.31 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903
- Result
- 0.127 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
-
Radium-228 4030 EPA method 904
- Result
- 0.183 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
-
Gross Beta Particle Activity 4100 EPA method 900
- Result
- 0.925 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Not recorded
-
Gross Alpha Particle Activity 4109 EPA method 900
- Result
- 1.152 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jul 1, 2009 – Sep 30, 2009
Routine (10).