This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0170018 , City of Southaven
30 of the 60 analytes this system has been tested for have been detected at least once, across 839 samples on record.
The other 30 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 839 samples on record, detections range from July 20, 1992 to June 22, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 424 of 451 results | Jul 20, 1992 | Jun 12, 2024 |
| Lead 1030 | Inorganic Chemical | 170 of 451 results | Jul 20, 1992 | Jun 11, 2024 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 64 of 96 results | May 5, 2004 | Feb 9, 2026 |
| Nitrate 1040 | Inorganic Chemical | 64 of 96 results | May 5, 2004 | Feb 9, 2026 |
| Fluoride 1025 | Inorganic Chemical | 52 of 53 results | Apr 16, 2002 | Jun 22, 2026 |
| Barium 1010 | Inorganic Chemical | 50 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| Nickel 1036 | Inorganic Chemical | 37 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| TTHM 2950 | Organic Chemical | 26 of 59 results | Mar 9, 2004 | Mar 17, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 22 of 57 results | Apr 14, 2004 | Mar 17, 2025 |
| Chromium 1020 | Inorganic Chemical | 19 of 50 results | Apr 16, 2002 | Jul 7, 2025 |
| Bromoform 2942 | Organic Chemical | 19 of 39 results | Jul 24, 2006 | Aug 1, 2017 |
| Dibromochloromethane 2944 | Organic Chemical | 17 of 39 results | Jul 24, 2006 | Jul 19, 2018 |
| Sodium 1052 | Inorganic Chemical | 12 of 12 results | Sep 24, 2019 | Oct 14, 2024 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 10 of 21 results | Dec 19, 2008 | May 13, 2019 |
| Radium-228 4030 | Radionuclide | 10 of 21 results | Dec 19, 2008 | May 13, 2019 |
| Selenium 1045 | Inorganic Chemical | 10 of 50 results | Apr 16, 2002 | Mar 31, 2008 |
| Radium-226 4020 | Radionuclide | 7 of 21 results | Sep 21, 2009 | May 13, 2019 |
| Bromodichloromethane 2943 | Organic Chemical | 7 of 39 results | Nov 15, 2006 | Jun 4, 2014 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 6 of 11 results | Mar 6, 2012 | May 13, 2019 |
| Sulfate 1055 | Inorganic Chemical | 6 of 11 results | Sep 10, 2003 | Jan 26, 2004 |
| Cadmium 1015 | Inorganic Chemical | 5 of 50 results | Apr 16, 2002 | Jan 23, 2006 |
| Monochloroacetic Acid 2450 | Organic Chemical | 4 of 33 results | Mar 5, 2014 | Jun 4, 2018 |
| Arsenic 1005 | Inorganic Chemical | 3 of 50 results | Jan 23, 2006 | Jan 23, 2006 |
| Thallium, Total 1085 | Inorganic Chemical | 2 of 50 results | Oct 1, 2018 | May 11, 2022 |
| Dichloroacetic Acid 2451 | Organic Chemical | 1 of 33 results | Sep 4, 2014 | Sep 4, 2014 |
| Gross Alpha, Excl. Radon & U 4000 | Radionuclide | 1 of 10 results | Sep 21, 2009 | Sep 21, 2009 |
| Gross Beta Particle Activity 4100 | Radionuclide | 1 of 1 result | Sep 21, 2009 | Sep 21, 2009 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 1 of 10 results | Sep 21, 2009 | Sep 21, 2009 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 33 results | Jun 30, 2009 | Jun 30, 2009 |
| Chloroform 2941 | Organic Chemical | 1 of 39 results | Nov 15, 2006 | Nov 15, 2006 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 91–100 of 839 samples, newest first — collected May 11, 2022 to January 23, 2023. The summary above covers all 839.
116 results from the 10 samples listed here: 15 detected, 101 not detected. Across the whole record it is 1,052 of 3,017. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.442 mg/l , sample collected Jan 23, 2023 11:28, sampling point TF083 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| 0.442 mg/l , sample collected Jan 23, 2023 11:28, sampling point TF083 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 23, 2023 11:28, sampling point TF083 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
|
||
| 0.412 mg/l , sample collected Jan 23, 2023 14:35, sampling point TF081 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| 0.412 mg/l , sample collected Jan 23, 2023 14:35, sampling point TF081 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 23, 2023 14:35, sampling point TF081 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 23, 2023 14:03, sampling point TF080 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 23, 2023 14:03, sampling point TF080 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 23, 2023 14:03, sampling point TF080 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2023 – Dec 31, 2023 |
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Benzene 2990 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Toluene 2991 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:15, sampling point TF084 | Styrene 2996 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Benzene 2990 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Toluene 2991 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 14:35, sampling point TF083 | Styrene 2996 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Benzene 2990 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Toluene 2991 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 17, 2022 15:20, sampling point TF081 | Styrene 2996 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0231 mg/l , sample collected May 11, 2022 14:30, sampling point TF084 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.662 mg/l , sample collected May 11, 2022 14:30, sampling point TF084 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0006 mg/l , sample collected May 11, 2022 14:30, sampling point TF084 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:30, sampling point TF084 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0247 mg/l , sample collected May 11, 2022 14:00, sampling point TF083 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.638 mg/l , sample collected May 11, 2022 14:00, sampling point TF083 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 14:00, sampling point TF083 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0279 mg/l , sample collected May 11, 2022 15:15, sampling point TF081 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.889 mg/l , sample collected May 11, 2022 15:15, sampling point TF081 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0007 mg/l , sample collected May 11, 2022 15:15, sampling point TF081 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 15:15, sampling point TF081 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.002 mg/l , sample collected May 11, 2022 15:15, sampling point TF081 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Arsenic 1005 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 0.0195 mg/l , sample collected May 11, 2022 13:00, sampling point TF080 | Barium 1010 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Cadmium 1015 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Chromium 1020 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| 1.25 mg/l , sample collected May 11, 2022 13:00, sampling point TF080 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Mercury 1035 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Selenium 1045 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 11, 2022 13:00, sampling point TF080 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2020 – Dec 31, 2022 |
-
- Collected
- Jan 23, 2023 11:28
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- NI-230124-012
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2023 – Dec 31, 2023
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- 0.442 mg/l
-
Nitrate 1040 EPA method QC10107041C
- Result
- 0.442 mg/l
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jan 23, 2023 14:35
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- NI-230124-014
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2023 – Dec 31, 2023
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- 0.412 mg/l
-
Nitrate 1040 EPA method QC10107041C
- Result
- 0.412 mg/l
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jan 23, 2023 14:03
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- NI-230124-015
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2023 – Dec 31, 2023
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- May 17, 2022 14:15
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- VO-220518-023
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2022
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- May 17, 2022 14:35
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- VO-220518-022
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2022
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- May 17, 2022 15:20
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- VO-220518-021
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2022
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- May 11, 2022 14:30
- Sampling point
- TF084 Treatment Plant T084
- Sample type
- Routine
- Lab sample
- IN-220512-051
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.0231 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 0.662 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- 0.0006 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
- Collected
- May 11, 2022 14:00
- Sampling point
- TF083 Treatment Plant T083
- Sample type
- Routine
- Lab sample
- IN-220512-050
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.0247 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 0.638 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
- Collected
- May 11, 2022 15:15
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- IN-220512-049
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.0279 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 0.889 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- 0.0007 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- 0.002 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
- Collected
- May 11, 2022 13:00
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- IN-220512-048
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Barium 1010 EPA method 200.8
- Result
- 0.0195 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- 1.25 mg/l
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
Routine (10).