Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Total Haloacetic Acids (Haa5) results

MS0180009 , S MS Public Water Auth-McLaurin

19 samples have been analysed for Total Haloacetic Acids (Haa5) at S MS Public Water Auth-McLaurin.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Total Haloacetic Acids (Haa5) result

The table below lists 11–19 of 19 samples, newest first — collected May 19, 2004 to April 25, 2023.

9 Total Haloacetic Acids (Haa5) results from the 9 samples listed here: 4 detected, 5 not detected. Those samples also carried 30 results for other analytes, which are on the full results page.

Units in this table

Total Haloacetic Acids (Haa5) is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

Total Haloacetic Acids (Haa5) results for S MS Public Water Auth-McLaurin, from 11 to 19 of 19 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Apr 25, 2023 12:55
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
HA-230426-014
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Apr 25, 2023 12:55, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Not recorded
Collected
Mar 3, 2022 11:50
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
HA-220304-002
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Mar 3, 2022 11:50, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Not recorded
Collected
Nov 17, 2020 12:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
201118-004HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Nov 17, 2020 12:30, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Not recorded
Collected
May 5, 2020 12:40
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
200506-003HA
Laboratory
MSDH Lab
0.003 mg/l , sample collected May 5, 2020 12:40, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Not recorded
Collected
Jul 24, 2018 12:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
180725-013HA
Laboratory
MSDH Lab
0.003 mg/l , sample collected Jul 24, 2018 12:30, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2017 – Dec 31, 2019
Collected
Sep 2, 2014 02:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
140903-003HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Sep 2, 2014 02:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2014 – Dec 31, 2016
Collected
Jul 10, 2012 01:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120711-014HA
Laboratory
MSDH Lab
0.001 mg/l , sample collected Jul 10, 2012 01:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2011 – Dec 31, 2013
Collected
Sep 15, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080916-014HA
Laboratory
MSDH Lab
0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. , sample collected Sep 15, 2008, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2008 – Dec 31, 2010
Collected
May 19, 2004
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
040520-014HA
Laboratory
MSDH Lab
Not detected below 0.01 mg/l Minimum Reporting Level , sample collected May 19, 2004, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2004 – Dec 31, 2004

Routine (9).