Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Combined Radium (-226 & -228) results

MS0220007 , Grenada Co W/S-Mondy Rd/Elliot

26 samples have been analysed for Combined Radium (-226 & -228) at Grenada Co W/S-Mondy Rd/Elliot.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Combined Radium (-226 & -228) result

The table below lists 11–20 of 26 samples, newest first — collected March 4, 2010 to May 15, 2012.

10 Combined Radium (-226 & -228) results from the 10 samples listed here: 6 detected, 4 not detected. Those samples also carried 45 results for other analytes, which are on the full results page.

Combined Radium (-226 & -228) results for Grenada Co W/S-Mondy Rd/Elliot, from 11 to 20 of 26 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
May 15, 2012 12:28
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120516-124
Laboratory
Radiation Safety Engineering
Not detected below 0.26 pci/l Minimum Reporting Level , sample collected May 15, 2012 12:28, sampling point TF103 Combined Radium (-226 & -228) 4010 Not recorded
Collected
May 15, 2012 12:44
Sampling point
TF104 Treatment Plant T104
Sample type
Routine
Lab sample
120516-125
Laboratory
Radiation Safety Engineering
Not detected below 0.27 pci/l Minimum Reporting Level , sample collected May 15, 2012 12:44, sampling point TF104 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 6, 2012 14:08
Sampling point
TF105 Treatment Plant T105
Sample type
Routine
Lab sample
120307-008
Laboratory
Radiation Safety Engineering
0.3 pci/l , sample collected Mar 6, 2012 14:08, sampling point TF105 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 6, 2012 13:41
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
120307-006
Laboratory
Radiation Safety Engineering
Not detected below 0.26 pci/l Minimum Reporting Level , sample collected Mar 6, 2012 13:41, sampling point TF103 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 6, 2012 13:52
Sampling point
TF104 Treatment Plant T104
Sample type
Routine
Lab sample
120307-007
Laboratory
Radiation Safety Engineering
Not detected below 0.27 pci/l Minimum Reporting Level , sample collected Mar 6, 2012 13:52, sampling point TF104 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 4, 2010
Sampling point
TF104 Treatment Plant T104
Sample type
Routine
Lab sample
00343-004
Laboratory
Laboratory, Ars
0.54 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Mar 4, 2010, sampling point TF104 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 4, 2010
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
00343-003
Laboratory
Laboratory, Ars
0.469 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Mar 4, 2010, sampling point TF103 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 4, 2010
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
00343-002
Laboratory
Laboratory, Ars
0.217 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Mar 4, 2010, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 4, 2010
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
00343-001
Laboratory
Laboratory, Ars
0.338 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Mar 4, 2010, sampling point TF080 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Mar 4, 2010
Sampling point
TF105 Treatment Plant T105
Sample type
Routine
Lab sample
00343-005
Laboratory
Laboratory, Ars
0.013 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Mar 4, 2010, sampling point TF105 Combined Radium (-226 & -228) 4010 Not recorded

Routine (10).