Radium-226 results
MS0240001 , City of Biloxi
56 samples have been analysed for Radium-226 at City of Biloxi.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Radium-226 result
The table below lists 21–30 of 56 samples, newest first — collected February 18, 2009 to June 4, 2018.
10 Radium-226 results from the 10 samples listed here: 3 detected, 7 not detected. Those samples also carried 40 results for other analytes, which are on the full results page.
Units in this table
Radium-226 is recorded on this page in ug/l and pci/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.3 pci/l Minimum Reporting Level , sample collected Jun 4, 2018 13:10, sampling point TF106 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2010 – Dec 31, 2018 |
|
||
| 0.39 pci/l , sample collected Jun 4, 2018 12:50, sampling point TF101 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2010 – Dec 31, 2018 |
|
||
| Not detected below 0.149 pci/l Minimum Reporting Level , sample collected Mar 12, 2014 09:42, sampling point TF116 | Radium-226 4020 EPA method 903.1 | Not recorded |
|
||
| Not detected below 0.252 pci/l Minimum Reporting Level , sample collected Nov 20, 2013 12:15, sampling point TF116 | Radium-226 4020 EPA method 903.1 | Not recorded |
|
||
| 0.266 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Oct 26, 2009, sampling point TF116 | Radium-226 4020 EPA method 903 | Oct 1, 2009 – Dec 31, 2009 |
|
||
| 0.575 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 25, 2009, sampling point TF116 | Radium-226 4020 EPA method 903 | Apr 1, 2009 – Jun 30, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF118 | Radium-226 4020 EPA method 903.1 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF117 | Radium-226 4020 EPA method 903.1 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF115 | Radium-226 4020 EPA method 903.1 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF114 | Radium-226 4020 EPA method 903.1 | Jan 1, 2009 – Mar 31, 2009 |
-
- Collected
- Jun 4, 2018 13:10
- Sampling point
- TF106 Treatment Plant T106
- Sample type
- Routine
- Lab sample
- 3955555
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2010 – Dec 31, 2018
-
Radium-226 4020 EPA method 7500-RAB
- Result
- Not detected below 0.3 pci/l Minimum Reporting Level
-
- Collected
- Jun 4, 2018 12:50
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 3955554
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2010 – Dec 31, 2018
-
Radium-226 4020 EPA method 7500-RAB
- Result
- 0.39 pci/l
-
- Collected
- Mar 12, 2014 09:42
- Sampling point
- TF116 Treatment Plant T116
- Sample type
- Routine
- Lab sample
- 201404280005
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.149 pci/l Minimum Reporting Level
-
- Collected
- Nov 20, 2013 12:15
- Sampling point
- TF116 Treatment Plant T116
- Sample type
- Routine
- Lab sample
- 201402280112
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.252 pci/l Minimum Reporting Level
-
- Collected
- Oct 26, 2009
- Sampling point
- TF116 Treatment Plant T116
- Sample type
- Routine
- Lab sample
- 02638-001
- Laboratory
- Laboratory, Ars
- Monitoring period
- Oct 1, 2009 – Dec 31, 2009
-
Radium-226 4020 EPA method 903
- Result
- 0.266 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Jun 25, 2009
- Sampling point
- TF116 Treatment Plant T116
- Sample type
- Routine
- Lab sample
- 01679-001
- Laboratory
- Laboratory, Ars
- Monitoring period
- Apr 1, 2009 – Jun 30, 2009
-
Radium-226 4020 EPA method 903
- Result
- 0.575 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Feb 18, 2009
- Sampling point
- TF118
- Sample type
- Routine
- Lab sample
- 225792049
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 18, 2009
- Sampling point
- TF117 Treatment Plant T117
- Sample type
- Routine
- Lab sample
- 225792048
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 18, 2009
- Sampling point
- TF115 Treatment Plant T115
- Sample type
- Routine
- Lab sample
- 225792046
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 18, 2009
- Sampling point
- TF114 Treatment Plant T114
- Sample type
- Routine
- Lab sample
- 225792045
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 1 pci/l Minimum Reporting Level
Routine (10).