Chemical and radiological sample results

MS0240194 , Riverbend Utilities Inc

35 of the 72 analytes this system has been tested for have been detected at least once, across 288 samples on record.

The other 37 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 288 samples on record, detections range from November 23, 1993 to February 11, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Riverbend Utilities Inc, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 85 of 90 results Nov 23, 1993 Jun 27, 2023
Lead 1030 Inorganic Chemical 71 of 90 results Nov 23, 1993 Jun 27, 2023
Barium 1010 Inorganic Chemical 26 of 26 results Sep 15, 2003 Feb 11, 2025
Fluoride 1025 Inorganic Chemical 23 of 30 results Sep 15, 2003 Feb 11, 2025
Arsenic 1005 Inorganic Chemical 17 of 26 results Sep 15, 2003 Feb 11, 2025
Sodium 1052 Inorganic Chemical 11 of 11 results May 15, 2012 Feb 12, 2024
Chromium 1020 Inorganic Chemical 8 of 26 results Sep 15, 2003 Apr 27, 2022
Sulfate 1055 Inorganic Chemical 7 of 8 results Sep 15, 2003 May 18, 2017
TTHM 2950 Organic Chemical 6 of 12 results May 24, 2004 May 16, 2023
Nickel 1036 Inorganic Chemical 6 of 26 results Sep 15, 2003 Apr 27, 2022
Gross Alpha, Incl. Radon & U 4002 Radionuclide 5 of 10 results Dec 14, 2011 Jul 12, 2012
Dichloroacetic Acid 2451 Organic Chemical 4 of 7 results Sep 5, 2007 Jul 23, 2019
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 4 of 12 results Sep 22, 2008 Jul 23, 2019
Chloroform 2941 Organic Chemical 4 of 7 results Jul 31, 2007 Jul 23, 2019
Bromodichloromethane 2943 Organic Chemical 4 of 7 results Jul 31, 2007 Jul 23, 2019
Calcium 1016 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Chloride 1017 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Iron 1028 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Magnesium 1031 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Manganese 1032 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Potassium 1042 Inorganic Chemical 4 of 4 results May 15, 2012 May 18, 2017
Residue, Total, Filterable 1057 Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Carbon Dioxide 1901 Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Color 1905 Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Hardness, Total (As Caco3) 1915 Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Alkalinity, Total 1927 Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Calculated Sodium NACA Water Quality 4 of 4 results May 15, 2012 May 18, 2017
PH, Field Result PHFD Water Quality 4 of 4 results May 15, 2012 May 18, 2017
Gross Alpha Particle Activity 4109 Radionuclide 4 of 4 results Jun 20, 2012 Jan 17, 2013
Trichloroacetic Acid 2452 Organic Chemical 2 of 7 results Sep 5, 2007 Jul 19, 2012
Dibromochloromethane 2944 Organic Chemical 2 of 7 results Sep 22, 2008 Jul 19, 2012
Antimony, Total 1074 Inorganic Chemical 1 of 26 results Apr 27, 2022 Apr 27, 2022
Monochloroacetic Acid 2450 Organic Chemical 1 of 7 results Sep 15, 2014 Sep 15, 2014
Dibromoacetic Acid 2454 Organic Chemical 1 of 7 results Jul 19, 2012 Jul 19, 2012
Alkalinity, Caco3 Stability 1067 Water Quality 1 of 1 result May 15, 2012 May 15, 2012

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 41–50 of 288 samples, newest first — collected March 2, 2021 to March 9, 2022. The summary above covers all 288.

16 results from the 10 samples listed here: 2 detected, 14 not detected. Across the whole record it is 345 of 1,489. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Riverbend Utilities Inc, every result from 41 to 50 of 288 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Mar 9, 2022 13:15
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
RU-220310-001
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 9, 2022 13:15, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Jan 1, 2014 – Dec 31, 2022
Collected
Jan 31, 2022 13:15
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
NI-220201-001
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 13:15, sampling point TF103 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 13:15, sampling point TF103 Nitrate 1040 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 13:15, sampling point TF103 Nitrite 1041 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Collected
Jan 31, 2022 12:45
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
NI-220201-002
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:45, sampling point TF102 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:45, sampling point TF102 Nitrate 1040 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:45, sampling point TF102 Nitrite 1041 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Collected
Jan 31, 2022 12:55
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
NI-220201-003
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:55, sampling point TF101 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:55, sampling point TF101 Nitrate 1040 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jan 31, 2022 12:55, sampling point TF101 Nitrite 1041 EPA method QC10107041C Jan 1, 2022 – Dec 31, 2022
Collected
Sep 8, 2021 14:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
HA-210909-014
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 8, 2021 14:30, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2021 – Dec 31, 2021
Collected
Sep 8, 2021 14:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
TH-210909-016
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 8, 2021 14:30, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2021 – Dec 31, 2021
Collected
May 12, 2021 13:45
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
CN-210513-029
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 12, 2021 13:45, sampling point TF103 Cyanide 1024 EPA method QC10204001X Jan 1, 2020 – Dec 31, 2022
Collected
May 12, 2021 13:15
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
CN-210513-030
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 12, 2021 13:15, sampling point TF102 Cyanide 1024 EPA method QC10204001X Jan 1, 2020 – Dec 31, 2022
Collected
Mar 2, 2021 12:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
NA-210303-007
Laboratory
MSDH Lab
37.6 mg/l , sample collected Mar 2, 2021 12:30, sampling point TF102 Sodium 1052 EPA method 200.7 Not recorded
Collected
Mar 2, 2021 12:45
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
NA-210303-006
Laboratory
MSDH Lab
37.2 mg/l , sample collected Mar 2, 2021 12:45, sampling point TF101 Sodium 1052 EPA method 200.7 Not recorded