Chemical and radiological sample results
MS0240270 , HCUA-West
11 of the 42 analytes this system has been tested for have been detected at least once, across 352 samples on record.
The other 31 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 352 samples on record, detections range from December 9, 2014 to February 12, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Xylenes, Total 2955 | Organic Chemical | 80 of 176 results | Mar 11, 2015 | Jan 5, 2022 |
| Ethylbenzene 2992 | Organic Chemical | 47 of 176 results | Mar 11, 2015 | May 18, 2021 |
| Barium 1010 | Inorganic Chemical | 24 of 24 results | Mar 9, 2015 | Feb 12, 2025 |
| Fluoride 1025 | Inorganic Chemical | 24 of 24 results | Mar 9, 2015 | Feb 12, 2025 |
| Sodium 1052 | Inorganic Chemical | 12 of 12 results | Mar 15, 2021 | Dec 3, 2024 |
| Chromium 1020 | Inorganic Chemical | 12 of 24 results | Mar 9, 2015 | Oct 23, 2018 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 10 of 12 results | Dec 9, 2014 | Mar 30, 2015 |
| Nickel 1036 | Inorganic Chemical | 3 of 24 results | Apr 26, 2022 | Feb 12, 2025 |
| Cyanide 1024 | Inorganic Chemical | 1 of 24 results | May 22, 2018 | May 22, 2018 |
| Arsenic 1005 | Inorganic Chemical | 1 of 24 results | Mar 11, 2015 | Mar 11, 2015 |
| Combined Uranium 4006 | Radionuclide | 1 of 26 results | Feb 5, 2015 | Feb 5, 2015 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 351–352 of 352 samples, newest first — collected December 9, 2014 to December 9, 2014. The summary above covers all 352.
4 results from the 2 samples listed here: 1 detected, 3 not detected. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 1.3 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Dec 9, 2014 15:15, sampling point TF101 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Oct 1, 2014 – Dec 31, 2014 |
|
||
| Not detected below 0.32 pci/l Minimum Reporting Level , sample collected Dec 9, 2014 15:15, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.306 pci/l Minimum Reporting Level , sample collected Dec 9, 2014 15:15, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Oct 1, 2014 – Dec 31, 2014 |
| Not detected below 0.32 pci/l Minimum Reporting Level , sample collected Dec 9, 2014 15:15, sampling point TF101 | Radium-228 4030 EPA method 904 | Oct 1, 2014 – Dec 31, 2014 |
-
- Collected
- Dec 9, 2014 15:15
- Sampling point
- TF101 Treatment Facility TF101
- Sample type
- Routine
- Lab sample
- 201412150005GA
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2014 – Dec 31, 2014
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.3 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Dec 9, 2014 15:15
- Sampling point
- TF101 Treatment Facility TF101
- Sample type
- Routine
- Lab sample
- 201412150005
- Laboratory
- Radiation Safety Engineering
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.32 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.306 pci/l Minimum Reporting Level
- Monitoring period
- Oct 1, 2014 – Dec 31, 2014
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 0.32 pci/l Minimum Reporting Level
- Monitoring period
- Oct 1, 2014 – Dec 31, 2014
Routine (2).