Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Cyanide results

MS0250008 , City of Jackson

78 samples have been analysed for Cyanide at City of Jackson.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Cyanide result

The table below lists 31–40 of 78 samples, newest first — collected May 22, 2017 to October 16, 2017.

10 Cyanide results from the 10 samples listed here: 4 detected, 6 not detected.

Cyanide results for City of Jackson, from 31 to 40 of 78 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Oct 16, 2017 07:55
Sampling point
IN071 Intake I071
Sample type
Routine
Lab sample
171016-001CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Oct 16, 2017 07:55, sampling point IN071 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
Sep 11, 2017 10:15
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
170912-008CN
Laboratory
MSDH Lab
0.177 mg/l , sample collected Sep 11, 2017 10:15, sampling point TF081 Cyanide 1024 EPA method QC10204001X Jul 1, 2017 – Sep 30, 2017
Collected
Sep 11, 2017 10:30
Sampling point
IN071 Intake I071
Sample type
Routine
Lab sample
170912-007CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Sep 11, 2017 10:30, sampling point IN071 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
Sep 11, 2017 08:55
Sampling point
IN072 Intake I072
Sample type
Routine
Lab sample
170912-006CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Sep 11, 2017 08:55, sampling point IN072 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
Jun 19, 2017 09:46
Sampling point
IN071 Intake I071
Sample type
Routine
Lab sample
170620-005CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Jun 19, 2017 09:46, sampling point IN071 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
Jun 19, 2017 08:05
Sampling point
IN072 Intake I072
Sample type
Routine
Lab sample
170620-003CN
Laboratory
MSDH Lab
0.017 mg/l , sample collected Jun 19, 2017 08:05, sampling point IN072 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
Jun 19, 2017 09:00
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
170620-002CN
Laboratory
MSDH Lab
0.032 mg/l , sample collected Jun 19, 2017 09:00, sampling point TF081 Cyanide 1024 EPA method QC10204001X Apr 1, 2017 – Jun 30, 2017
Collected
May 22, 2017 08:11
Sampling point
IN071 Intake I071
Sample type
Routine
Lab sample
170523-013CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 22, 2017 08:11, sampling point IN071 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
May 22, 2017 07:00
Sampling point
IN072 Intake I072
Sample type
Routine
Lab sample
170523-012CN
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 22, 2017 07:00, sampling point IN072 Cyanide 1024 EPA method QC10204001X Not recorded
Collected
May 22, 2017 08:06
Sampling point
TF081 Treatment Plant T081
Sample type
Routine
Lab sample
170523-011CN
Laboratory
MSDH Lab
0.112 mg/l , sample collected May 22, 2017 08:06, sampling point TF081 Cyanide 1024 EPA method QC10204001X Apr 1, 2017 – Jun 30, 2017

Routine (10).