This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Gross Alpha Particle Activity results
MS0250015 , North Hinds W/A #1-Brownsville
7 samples have been analysed for Gross Alpha Particle Activity at North Hinds W/A #1-Brownsville.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Gross Alpha Particle Activity result
All 7 samples analysed for this analyte are listed below, newest first. No date range is applied.
7 Gross Alpha Particle Activity results from the 7 samples listed here: 4 detected, 3 not detected. Those samples also carried 11 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.7 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 12, 2013 08:10, sampling point TF107 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Not recorded |
|
||
| 0.6 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 12, 2013 08:00, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Not recorded |
|
||
| 1.8 pci/l , sample collected Sep 26, 2012 08:40, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 1 pci/l , sample collected Jun 29, 2012 10:00, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 2.91 pci/l Minimum Reporting Level , sample collected Jun 25, 2012 22:35, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 900.0 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 2.88 pci/l Minimum Reporting Level , sample collected Mar 22, 2012 09:00, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 900.0 | Not recorded |
|
||
| Not detected below 3 pci/l Minimum Reporting Level , sample collected Dec 12, 2011 10:00, sampling point TF102 | Gross Alpha Particle Activity 4109 EPA method 900.0 | Not recorded |
-
- Collected
- Sep 12, 2013 08:10
- Sampling point
- TF107 Treatment Facility TF107
- Sample type
- Routine
- Lab sample
- 201309260161
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.7 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Sep 12, 2013 08:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201309260160
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.6 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Sep 26, 2012 08:40
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201212140241
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 1.8 pci/l
-
- Collected
- Jun 29, 2012 10:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201208130176
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 1 pci/l
-
- Collected
- Jun 25, 2012 22:35
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 307271001
- Laboratory
- Gel Laboratories
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Gross Alpha Particle Activity 4109 EPA method 900.0
- Result
- Not detected below 2.91 pci/l Minimum Reporting Level
-
- Collected
- Mar 22, 2012 09:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 298368001
- Laboratory
- Gel Laboratories
- Monitoring period
- Not recorded
-
Gross Alpha Particle Activity 4109 EPA method 900.0
- Result
- Not detected below 2.88 pci/l Minimum Reporting Level
-
- Collected
- Dec 12, 2011 10:00
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 292316001
- Laboratory
- Gel Laboratories
- Monitoring period
- Not recorded
-
Gross Alpha Particle Activity 4109 EPA method 900.0
- Result
- Not detected below 3 pci/l Minimum Reporting Level
Routine (7).