TTHM results

MS0250023 , South Terry Water Assn

75 samples have been analysed for TTHM at South Terry Water Assn.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every TTHM result

The table below lists 61–70 of 75 samples, newest first — collected December 22, 2009 to February 15, 2012.

10 TTHM results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 40 results for other analytes, which are on the full results page.

Units in this table

TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

TTHM results for South Terry Water Assn, from 61 to 70 of 75 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Feb 15, 2012 14:02
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120216-006TH
Laboratory
MSDH Lab
47.5 ug/l , sample collected Feb 15, 2012 14:02, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2012 – Mar 31, 2012
Collected
Nov 17, 2011 11:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
111118-009TH
Laboratory
MSDH Lab
54.1 ug/l , sample collected Nov 17, 2011 11:30, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2011 – Dec 31, 2011
Collected
Sep 14, 2011 05:40
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110915-007TH
Laboratory
MSDH Lab
76 ug/l , sample collected Sep 14, 2011 05:40, sampling point MRT000 TTHM 2950 EPA method 524.2 Jul 1, 2011 – Sep 30, 2011
Collected
May 10, 2011
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110511-010TH
Laboratory
MSDH Lab
55.4 ug/l , sample collected May 10, 2011, sampling point MRT000 TTHM 2950 EPA method 524.2 Apr 1, 2011 – Jun 30, 2011
Collected
Feb 17, 2011
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110218-002TH
Laboratory
MSDH Lab
22.8 ug/l , sample collected Feb 17, 2011, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2011 – Mar 31, 2011
Collected
Nov 18, 2010
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
101119-006TH
Laboratory
MSDH Lab
18.67 ug/l , sample collected Nov 18, 2010, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2010 – Dec 31, 2010
Collected
Jul 20, 2010
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
100721-019TH
Laboratory
MSDH Lab
61.12 ug/l , sample collected Jul 20, 2010, sampling point MRT000 TTHM 2950 EPA method 524.2 Jul 1, 2010 – Sep 30, 2010
Collected
May 12, 2010
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
100513-009TH
Laboratory
MSDH Lab
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected May 12, 2010, sampling point MRT000 TTHM 2950 EPA method 524.2 Apr 1, 2010 – Jun 30, 2010
Collected
Feb 11, 2010
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
100212-001TH
Laboratory
MSDH Lab
22.48 ug/l , sample collected Feb 11, 2010, sampling point DS000 TTHM 2950 EPA method 524.2 Jan 1, 2010 – Mar 31, 2010
Collected
Dec 22, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
091223-001TH
Laboratory
MSDH Lab
60.53 ug/l , sample collected Dec 22, 2009, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2009 – Dec 31, 2009

Routine (10).