Combined Radium (-226 & -228) results
MS0300004 , City of Gautier
24 samples have been analysed for Combined Radium (-226 & -228) at City of Gautier.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Combined Radium (-226 & -228) result
The table below lists 1–10 of 24 samples, newest first — collected September 29, 2011 to May 23, 2019.
10 Combined Radium (-226 & -228) results from the 10 samples listed here: 3 detected, 7 not detected. Those samples also carried 26 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.93 pci/l , sample collected May 23, 2019 09:00, sampling point TF108 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Apr 4, 2018 12:15, sampling point TF104 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Apr 4, 2018 12:00, sampling point TF109 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.7 pci/l Minimum Reporting Level , sample collected Apr 3, 2018 11:30, sampling point TF111 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| 0.96 pci/l , sample collected Apr 3, 2018 11:15, sampling point TF107 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| 1.04 pci/l , sample collected Apr 3, 2018 11:00, sampling point TF106 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Apr 3, 2018 11:00, sampling point TF101 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Mar 21, 2018 12:00, sampling point TF108 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.727 pci/l Minimum Reporting Level , sample collected Dec 5, 2011 13:00, sampling point TF111 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.757 pci/l Minimum Reporting Level , sample collected Sep 29, 2011 13:10, sampling point TF111 | Combined Radium (-226 & -228) 4010 | Not recorded |
-
- Collected
- May 23, 2019 09:00
- Sampling point
- TF108 Treatment Plant T108
- Sample type
- Routine
- Lab sample
- 4318595
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 0.93 pci/l
-
- Collected
- Apr 4, 2018 12:15
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 3905724
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
-
- Collected
- Apr 4, 2018 12:00
- Sampling point
- TF109 Treatment Plant T109
- Sample type
- Routine
- Lab sample
- 3905722
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
-
- Collected
- Apr 3, 2018 11:30
- Sampling point
- TF111
- Sample type
- Routine
- Lab sample
- 3904352
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.7 pci/l Minimum Reporting Level
-
- Collected
- Apr 3, 2018 11:15
- Sampling point
- TF107 Treatment Plant T107
- Sample type
- Routine
- Lab sample
- 3904350
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 0.96 pci/l
-
- Collected
- Apr 3, 2018 11:00
- Sampling point
- TF106 Treatment Plant T106
- Sample type
- Routine
- Lab sample
- 3904346
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 1.04 pci/l
-
- Collected
- Apr 3, 2018 11:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 3904345
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
-
- Collected
- Mar 21, 2018 12:00
- Sampling point
- TF108 Treatment Plant T108
- Sample type
- Routine
- Lab sample
- 3896652
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
- Collected
- Dec 5, 2011 13:00
- Sampling point
- TF111
- Sample type
- Routine
- Lab sample
- 291759013
- Laboratory
- Gel Laboratories
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.727 pci/l Minimum Reporting Level
-
- Collected
- Sep 29, 2011 13:10
- Sampling point
- TF111
- Sample type
- Routine
- Lab sample
- 287215007
- Laboratory
- Gel Laboratories
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.757 pci/l Minimum Reporting Level
Routine (10).