This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Total Haloacetic Acids (Haa5) results
MS0300014 , Jackson Co West Port Auth.
7 samples have been analysed for Total Haloacetic Acids (Haa5) at Jackson Co West Port Auth..
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Total Haloacetic Acids (Haa5) result
All 7 samples analysed for this analyte are listed below, newest first. No date range is applied.
7 Total Haloacetic Acids (Haa5) results from the 7 samples listed here: 6 detected, 1 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.
Units in this table
Total Haloacetic Acids (Haa5) is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 6.16 ug/l , sample collected Mar 29, 2023 14:31, sampling point SM1 | Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 | Not recorded |
|
||
| 6.64 ug/l , sample collected Oct 17, 2022 15:13, sampling point SM1 | Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 | Not recorded |
|
||
| 0.002 mg/l , sample collected Sep 24, 2014 11:00, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 | Jan 1, 2014 – Dec 31, 2016 |
|
||
| 0.008 mg/l , sample collected Aug 7, 2013 11:00, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| 0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. , sample collected Jun 8, 2010, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| 0.007 mg/l , sample collected Sep 27, 2007, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 0.01 mg/l Minimum Reporting Level , sample collected Jun 14, 2004, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 | Jan 1, 2004 – Dec 31, 2004 |
-
- Collected
- Mar 29, 2023 14:31
- Sampling point
- SM1 2300 Port Rd - Elevated Storage Tank
- Sample type
- Routine
- Lab sample
- HA-230330-013
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Total Haloacetic Acids (Haa5) 2456 EPA method 552.2
- Result
- 6.16 ug/l
-
- Collected
- Oct 17, 2022 15:13
- Sampling point
- SM1 2300 Port Rd - Elevated Storage Tank
- Sample type
- Routine
- Lab sample
- HA-221018-011
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Total Haloacetic Acids (Haa5) 2456 EPA method 552.2
- Result
- 6.64 ug/l
-
- Collected
- Sep 24, 2014 11:00
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 140925-009HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Total Haloacetic Acids (Haa5) 2456
- Result
- 0.002 mg/l
-
- Collected
- Aug 7, 2013 11:00
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 130808-001HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Total Haloacetic Acids (Haa5) 2456
- Result
- 0.008 mg/l
-
- Collected
- Jun 8, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100609-007HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Total Haloacetic Acids (Haa5) 2456
- Result
- 0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here.
-
- Collected
- Sep 27, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070928-020HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Total Haloacetic Acids (Haa5) 2456
- Result
- 0.007 mg/l
-
- Collected
- Jun 14, 2004
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 040615-021HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2004 – Dec 31, 2004
-
Total Haloacetic Acids (Haa5) 2456 EPA method 552.2
- Result
- Not detected below 0.01 mg/l Minimum Reporting Level
Routine (7).