Chemical and radiological sample results

MS0310011 , Rose Hill Water Association

40 of the 74 analytes this system has been tested for have been detected at least once, across 254 samples on record.

The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 254 samples on record, detections range from September 24, 2003 to November 20, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Rose Hill Water Association, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 60 of 60 results Jul 24, 2007 Jul 17, 2023
Lead 1030 Inorganic Chemical 49 of 60 results Jul 24, 2007 Jul 17, 2023
TTHM 2950 Organic Chemical 22 of 22 results Jun 16, 2004 Aug 18, 2025
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 20 of 23 results Sep 20, 2006 Nov 20, 2025
Barium 1010 Inorganic Chemical 20 of 20 results Sep 24, 2003 Feb 24, 2025
Chloroform 2941 Organic Chemical 16 of 16 results Sep 20, 2006 Aug 18, 2025
Fluoride 1025 Inorganic Chemical 16 of 21 results Sep 24, 2003 Feb 24, 2025
Bromodichloromethane 2943 Organic Chemical 15 of 16 results Sep 20, 2006 Aug 18, 2025
Dibromochloromethane 2944 Organic Chemical 15 of 16 results Sep 20, 2006 Aug 18, 2025
Dichloroacetic Acid 2451 Organic Chemical 14 of 15 results Aug 27, 2012 Nov 20, 2025
Trichloroacetic Acid 2452 Organic Chemical 14 of 15 results Aug 27, 2012 Nov 20, 2025
Gross Alpha, Incl. Radon & U 4002 Radionuclide 11 of 11 results Dec 12, 2011 May 29, 2014
Dibromoacetic Acid 2454 Organic Chemical 8 of 15 results Aug 27, 2012 Nov 20, 2025
Sodium 1052 Inorganic Chemical 7 of 7 results Oct 30, 2013 Feb 3, 2025
Nickel 1036 Inorganic Chemical 7 of 20 results Sep 24, 2003 Jan 12, 2009
Chromium 1020 Inorganic Chemical 5 of 20 results Sep 24, 2003 Apr 8, 2015
Bromoform 2942 Organic Chemical 4 of 16 results May 29, 2024 Nov 11, 2024
Xylenes, Total 2955 Organic Chemical 3 of 39 results Aug 2, 2004 Nov 16, 2005
Ethylbenzene 2992 Organic Chemical 3 of 39 results Aug 2, 2004 Nov 16, 2005
Monochloroacetic Acid 2450 Organic Chemical 1 of 15 results Jul 29, 2019 Jul 29, 2019
Combined Radium (-226 & -228) 4010 Radionuclide 1 of 12 results Mar 10, 2014 Mar 10, 2014
Radium-228 4030 Radionuclide 1 of 12 results Mar 10, 2014 Mar 10, 2014
Gross Alpha Particle Activity 4109 Radionuclide 1 of 1 result Mar 10, 2014 Mar 10, 2014
Calcium 1016 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Chloride 1017 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Iron 1028 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Magnesium 1031 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Manganese 1032 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Potassium 1042 Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Residue, Total, Filterable 1057 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Alkalinity, Caco3 Stability 1067 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Carbon Dioxide 1901 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Color 1905 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Hardness, Total (As Caco3) 1915 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Alkalinity, Total 1927 Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Iron, Field Result FEFD Inorganic Chemical 1 of 1 result Oct 30, 2013 Oct 30, 2013
Calculated Sodium NACA Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
PH, Field Result PHFD Water Quality 1 of 1 result Oct 30, 2013 Oct 30, 2013
Nitrate-Nitrite 1038 Inorganic Chemical 1 of 45 results May 19, 2004 May 19, 2004
Nitrate 1040 Inorganic Chemical 1 of 45 results May 19, 2004 May 19, 2004

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 61–70 of 254 samples, newest first — collected September 17, 2019 to June 22, 2020. The summary above covers all 254.

23 results from the 10 samples listed here: 10 detected, 13 not detected. Across the whole record it is 330 of 1,588. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Rose Hill Water Association, every result from 61 to 70 of 254 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jun 22, 2020 06:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200623-055PB
Laboratory
MSDH Lab
0.0912 mg/l , sample collected Jun 22, 2020 06:00, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0007 mg/l , sample collected Jun 22, 2020 06:00, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Jun 22, 2020 07:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200623-054PB
Laboratory
MSDH Lab
0.0138 mg/l , sample collected Jun 22, 2020 07:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jun 22, 2020 07:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Jun 22, 2020 08:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200623-053PB
Laboratory
MSDH Lab
0.5401 mg/l , sample collected Jun 22, 2020 08:00, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0006 mg/l , sample collected Jun 22, 2020 08:00, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Jun 22, 2020 06:13
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200623-052PB
Laboratory
MSDH Lab
0.0089 mg/l , sample collected Jun 22, 2020 06:13, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0005 mg/l , sample collected Jun 22, 2020 06:13, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Jun 22, 2020 06:32
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200623-051PB
Laboratory
MSDH Lab
0.6774 mg/l , sample collected Jun 22, 2020 06:32, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0043 mg/l , sample collected Jun 22, 2020 06:32, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Feb 25, 2020 12:04
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
200226-043NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:04, sampling point TF103 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:04, sampling point TF103 Nitrate 1040 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:04, sampling point TF103 Nitrite 1041 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Collected
Feb 25, 2020 12:15
Sampling point
TF104 Treatment Faciility TF104
Sample type
Routine
Lab sample
200226-042NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:15, sampling point TF104 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:15, sampling point TF104 Nitrate 1040 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Feb 25, 2020 12:15, sampling point TF104 Nitrite 1041 EPA method QC10107041C Jan 1, 2020 – Dec 31, 2020
Collected
Nov 4, 2019 12:20
Sampling point
TF104 Treatment Faciility TF104
Sample type
Routine
Lab sample
191105-002NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Nov 4, 2019 12:20, sampling point TF104 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Nov 4, 2019 12:20, sampling point TF104 Nitrate 1040 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Nov 4, 2019 12:20, sampling point TF104 Nitrite 1041 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Collected
Oct 28, 2019 12:20
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
191029-003NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Oct 28, 2019 12:20, sampling point TF103 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Oct 28, 2019 12:20, sampling point TF103 Nitrate 1040 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Oct 28, 2019 12:20, sampling point TF103 Nitrite 1041 EPA method QC10107041C Jan 1, 2019 – Dec 31, 2019
Collected
Sep 17, 2019 11:00
Sampling point
TF104 Treatment Faciility TF104
Sample type
Routine
Lab sample
680-174251-9
Laboratory
Test America-Savannah
100000 ug/l , sample collected Sep 17, 2019 11:00, sampling point TF104 Sodium 1052 EPA method 200.7 Not recorded

Routine (10).