Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

TTHM results

MS0330007 , Northeast Jeff Davis W/A

20 samples have been analysed for TTHM at Northeast Jeff Davis W/A.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every TTHM result

The table below lists 11–20 of 20 samples, newest first — collected June 16, 2004 to February 28, 2024.

10 TTHM results from the 10 samples listed here: 3 detected, 7 not detected. Those samples also carried 34 results for other analytes, which are on the full results page.

Units in this table

TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

We withheld the location of 1 sampling point below. The location on record identifies a private home, and we do not publish those. That is our decision, not the agency’s. The sampling point, its type and every result taken there are published unchanged.

TTHM results for Northeast Jeff Davis W/A, from 11 to 20 of 20 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Feb 28, 2024 12:15
Sampling point
SM1 Location withheld
Sample type
Routine
Lab sample
810-95607-1
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Feb 28, 2024 12:15, sampling point SM1 TTHM 2950 EPA method 524.2 Jan 1, 2024 – Mar 31, 2024
Collected
May 22, 2023 13:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
TH-230523-020
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected May 22, 2023 13:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2023 – Dec 31, 2023
Collected
Mar 21, 2022 14:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
TH-220322-009
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Mar 21, 2022 14:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2022 – Dec 31, 2022
Collected
Jun 17, 2020 13:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200618-001TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Jun 17, 2020 13:00, sampling point DS000 TTHM 2950 Jan 1, 2020 – Dec 31, 2020
Collected
Apr 22, 2019 13:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
190423-013TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Apr 22, 2019 13:00, sampling point MRT000 TTHM 2950 Jan 1, 2019 – Dec 31, 2019
Collected
Jun 29, 2015 02:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
150630-021TH
Laboratory
MSDH Lab
9.86 ug/l , sample collected Jun 29, 2015 02:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2014 – Dec 31, 2016
Collected
Sep 6, 2012 01:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120907-017TH
Laboratory
MSDH Lab
Not detected below 4 ug/l Minimum Reporting Level , sample collected Sep 6, 2012 01:00, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2011 – Dec 31, 2013
Collected
Sep 23, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
090924-022TH
Laboratory
MSDH Lab
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 23, 2009, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2008 – Dec 31, 2010
Collected
Aug 8, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070809-004TH
Laboratory
MSDH Lab
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Aug 8, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2005 – Dec 31, 2007
Collected
Jun 16, 2004
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
040617-011TH
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 16, 2004, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2004 – Dec 31, 2004

Routine (10).