This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Vinyl Chloride results
MS0360013 , Punkin W/A #1
67 samples have been analysed for Vinyl Chloride at Punkin W/A #1.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Vinyl Chloride result
The table below lists 61–67 of 67 samples, newest first — collected June 13, 2002 to July 30, 2013.
7 Vinyl Chloride results from the 7 samples listed here: 0 detected, 7 not detected. Those samples also carried 140 results for other analytes, which are on the full results page.
Units in this table
Vinyl Chloride is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jul 30, 2013 01:00, sampling point TF081 | Vinyl Chloride 2976 EPA method 524.2 | Jul 1, 2013 – Sep 30, 2013 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Mar 23, 2009, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Nov 2, 2004, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Oct 1, 2004 – Dec 31, 2004 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Aug 3, 2004, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Jul 1, 2004 – Sep 30, 2004 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected May 5, 2004, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Apr 1, 2004 – Jun 30, 2004 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 3, 2004, sampling point TF080 | Vinyl Chloride 2976 | Jan 1, 2004 – Mar 31, 2004 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Jun 13, 2002, sampling point TF080 | Vinyl Chloride 2976 | Not recorded |
-
- Collected
- Jul 30, 2013 01:00
- Sampling point
- TF081 Treatment Facility TF081
- Sample type
- Routine
- Lab sample
- 130731-007VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2013 – Sep 30, 2013
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- Mar 23, 2009
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 090324-019VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2010
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Nov 2, 2004
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 041103-028VO
- Laboratory
- MSDH Lab
- Monitoring period
- Oct 1, 2004 – Dec 31, 2004
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Aug 3, 2004
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 040804-029VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2004 – Sep 30, 2004
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- May 5, 2004
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 040506-013VO
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2004 – Jun 30, 2004
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Feb 3, 2004
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 040204-059VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2004 – Mar 31, 2004
-
Vinyl Chloride 2976
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Jun 13, 2002
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 020614-007VO
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
Vinyl Chloride 2976
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
Routine (7).