Total Haloacetic Acids (Haa5) results

MS0360015 , University of Mississippi

41 samples have been analysed for Total Haloacetic Acids (Haa5) at University of Mississippi.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Total Haloacetic Acids (Haa5) result

The table below lists 31–40 of 41 samples, newest first — collected August 14, 2007 to March 19, 2014.

10 Total Haloacetic Acids (Haa5) results from the 10 samples listed here: 4 detected, 6 not detected. Those samples also carried 45 results for other analytes, which are on the full results page.

Total Haloacetic Acids (Haa5) results for University of Mississippi, from 31 to 40 of 41 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Mar 19, 2014 12:30
Sampling point
SM2 Lyceum #10
Sample type
Routine
Lab sample
140320-003HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Mar 19, 2014 12:30, sampling point SM2 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2014 – Mar 31, 2014
Collected
Dec 16, 2013 01:22
Sampling point
SM4 Weir #24
Sample type
Routine
Lab sample
131217-043HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Dec 16, 2013 01:22, sampling point SM4 Total Haloacetic Acids (Haa5) 2456 Oct 1, 2013 – Dec 31, 2013
Collected
Dec 16, 2013 01:30
Sampling point
SM3 Crosby #6
Sample type
Routine
Lab sample
131217-042HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Dec 16, 2013 01:30, sampling point SM3 Total Haloacetic Acids (Haa5) 2456 Oct 1, 2013 – Dec 31, 2013
Collected
Dec 16, 2013 01:55
Sampling point
SM2 Lyceum #10
Sample type
Routine
Lab sample
131217-031HA
Laboratory
MSDH Lab
0.002 mg/l , sample collected Dec 16, 2013 01:55, sampling point SM2 Total Haloacetic Acids (Haa5) 2456 Oct 1, 2013 – Dec 31, 2013
Collected
Dec 16, 2013 02:08
Sampling point
SM1 WWTP #1
Sample type
Routine
Lab sample
131217-030HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Dec 16, 2013 02:08, sampling point SM1 Total Haloacetic Acids (Haa5) 2456 Oct 1, 2013 – Dec 31, 2013
Collected
Jul 10, 2013 01:20
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
130711-001HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Jul 10, 2013 01:20, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2013 – Dec 31, 2013
Collected
Sep 4, 2012 01:20
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120905-007HA
Laboratory
MSDH Lab
0.001 mg/l , sample collected Sep 4, 2012 01:20, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2012 – Dec 31, 2012
Collected
Jun 6, 2012 01:00
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120607-002HA
Laboratory
MSDH Lab
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Jun 6, 2012 01:00, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2012 – Dec 31, 2012
Collected
Sep 23, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
090924-012HA
Laboratory
MSDH Lab
0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 23, 2009, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2008 – Dec 31, 2010
Collected
Aug 14, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070815-016HA
Laboratory
MSDH Lab
0.0016 mg/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Aug 14, 2007, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2005 – Dec 31, 2007

Routine (10).