Chemical and radiological sample results
MS0370010 , Town of Sumrall
26 of the 58 analytes this system has been tested for have been detected at least once, across 193 samples on record.
The other 32 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 193 samples on record, detections range from September 29, 2003 to December 29, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 60 of 60 results | Jul 31, 2007 | Sep 11, 2023 |
| Lead 1030 | Inorganic Chemical | 28 of 60 results | Jul 31, 2007 | Sep 11, 2023 |
| Barium 1010 | Inorganic Chemical | 14 of 14 results | Sep 29, 2003 | Feb 26, 2025 |
| Nickel 1036 | Inorganic Chemical | 13 of 14 results | Sep 29, 2003 | Feb 26, 2025 |
| Arsenic 1005 | Inorganic Chemical | 12 of 14 results | Sep 29, 2003 | Feb 26, 2025 |
| TTHM 2950 | Organic Chemical | 7 of 10 results | Jun 21, 2004 | Dec 29, 2025 |
| Sodium 1052 | Inorganic Chemical | 6 of 6 results | Sep 16, 2019 | Feb 18, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 6 of 7 results | Dec 13, 2011 | Dec 15, 2015 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 6 of 7 results | Dec 13, 2011 | Dec 15, 2015 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 5 of 12 results | Sep 22, 2009 | Dec 8, 2025 |
| Nitrite 1041 | Inorganic Chemical | 5 of 34 results | Aug 15, 2005 | Feb 22, 2023 |
| Radium-228 4030 | Radionuclide | 5 of 7 results | Dec 13, 2011 | Jul 17, 2012 |
| Chloroform 2941 | Organic Chemical | 4 of 6 results | Jun 26, 2013 | Dec 29, 2025 |
| Dichloroacetic Acid 2451 | Organic Chemical | 4 of 6 results | Sep 22, 2009 | Dec 8, 2025 |
| Trichloroacetic Acid 2452 | Organic Chemical | 3 of 6 results | Jul 6, 2015 | Dec 8, 2025 |
| Bromodichloromethane 2943 | Organic Chemical | 3 of 6 results | Jun 26, 2013 | Dec 8, 2025 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 3 of 34 results | Mar 6, 2017 | Mar 10, 2021 |
| Nitrate 1040 | Inorganic Chemical | 3 of 34 results | Mar 6, 2017 | Mar 10, 2021 |
| Fluoride 1025 | Inorganic Chemical | 2 of 14 results | Mar 21, 2005 | Sep 6, 2022 |
| Sulfate 1055 | Inorganic Chemical | 2 of 2 results | Sep 29, 2003 | Mar 1, 2004 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 6 results | Dec 8, 2025 | Dec 8, 2025 |
| Bromoform 2942 | Organic Chemical | 1 of 6 results | Dec 8, 2025 | Dec 8, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 1 of 6 results | Dec 8, 2025 | Dec 8, 2025 |
| Chromium 1020 | Inorganic Chemical | 1 of 14 results | Mar 23, 2020 | Mar 23, 2020 |
| Radium-226 4020 | Radionuclide | 1 of 7 results | Dec 15, 2015 | Dec 15, 2015 |
| Selenium 1045 | Inorganic Chemical | 1 of 14 results | Mar 1, 2004 | Mar 1, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 51–60 of 193 samples, newest first — collected April 20, 2020 to July 15, 2020. The summary above covers all 193.
65 results from the 10 samples listed here: 11 detected, 54 not detected. Across the whole record it is 197 of 998. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.1088 mg/l , sample collected Jul 15, 2020 06:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| 0.0006 mg/l , sample collected Jul 15, 2020 06:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.1092 mg/l , sample collected Jul 15, 2020 10:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| 0.0012 mg/l , sample collected Jul 15, 2020 10:00, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.1068 mg/l , sample collected Jul 15, 2020, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 15, 2020, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.2395 mg/l , sample collected Jul 15, 2020, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 15, 2020, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0123 mg/l , sample collected Jul 15, 2020 05:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| 0.001 mg/l , sample collected Jul 15, 2020 05:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Benzene 2990 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Toluene 2991 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:58, sampling point TF080 | Styrene 2996 EPA method 524.2 | Jan 1, 2017 – Dec 31, 2022 |
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Benzene 2990 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Toluene 2991 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected May 5, 2020 12:45, sampling point TF103 | Styrene 2996 EPA method 524.2 | Jan 1, 2020 – Dec 31, 2020 |
|
||
| Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 5, 2020 13:35, sampling point TF080 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2020 – Dec 31, 2022 |
|
||
| Not detected below 0.015 mg/l Minimum Reporting Level , sample collected May 5, 2020 13:25, sampling point TF103 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0009 mg/l , sample collected Apr 20, 2020 13:10, sampling point TF103 | Arsenic 1005 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| 0.0737 mg/l , sample collected Apr 20, 2020 13:10, sampling point TF103 | Barium 1010 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Cadmium 1015 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Chromium 1020 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Mercury 1035 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| 0.0006 mg/l , sample collected Apr 20, 2020 13:10, sampling point TF103 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Selenium 1045 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 20, 2020 13:10, sampling point TF103 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
-
- Collected
- Jul 15, 2020 06:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200716-005PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.1088 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0006 mg/l
-
- Collected
- Jul 15, 2020 10:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200716-004PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.1092 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0012 mg/l
-
- Collected
- Jul 15, 2020
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200716-003PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.1068 mg/l
-
Lead 1030 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Jul 15, 2020
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200716-002PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.2395 mg/l
-
Lead 1030 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Jul 15, 2020 05:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200716-001PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0123 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.001 mg/l
-
- Collected
- May 5, 2020 12:58
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 200506-011VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2022
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- May 5, 2020 12:45
- Sampling point
- TF103 Treatment Facility TF103
- Sample type
- Routine
- Lab sample
- 200506-010VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2020
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- May 5, 2020 13:35
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 200506-016CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2022
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.015 mg/l Minimum Reporting Level
-
- Collected
- May 5, 2020 13:25
- Sampling point
- TF103 Treatment Facility TF103
- Sample type
- Routine
- Lab sample
- 200506-015CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.015 mg/l Minimum Reporting Level
-
- Collected
- Apr 20, 2020 13:10
- Sampling point
- TF103 Treatment Facility TF103
- Sample type
- Routine
- Lab sample
- 200421-002IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- 0.0009 mg/l
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Barium 1010 EPA method 200.8
- Result
- 0.0737 mg/l
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Nickel 1036 EPA method 200.8
- Result
- 0.0006 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
Routine (10).