MS0380106 , Long Creek Water Assn #2

Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.

Lead and copper 90th-percentile sample summaries for Long Creek Water Assn #2, 24 summaries, every one on record. The agency records no date of receipt for any of them.
Analyte Monitoring period Samples 90th percentile Facility Data quality
Copper Jan 1, 2022 – Dec 31, 2024 20 0.235 mg/l DS000 Accepted
Lead Jan 1, 2022 – Dec 31, 2024 20 0.0006 mg/l DS000 Accepted
Copper Jan 1, 2019 – Dec 31, 2021 20 0.16 mg/l DS000 Accepted
Lead Jan 1, 2019 – Dec 31, 2021 20 0.0006 mg/l DS000 Accepted
Copper Jan 1, 2016 – Dec 31, 2018 20 0.1653 mg/l DS000 Accepted
Lead Jan 1, 2016 – Dec 31, 2018 20 0.0008 mg/l DS000 Accepted
Copper Jan 1, 2014 – Dec 31, 2016 20 0.1371 mg/l DS000 Accepted
Lead Jan 1, 2014 – Dec 31, 2016 20 0.0036 mg/l DS000 Accepted
Copper Jan 1, 2011 – Dec 31, 2013 20 0.1723 mg/l DS000 Accepted
Lead Jan 1, 2011 – Dec 31, 2013 20 0.0009 mg/l DS000 Accepted
Copper Jan 1, 2008 – Dec 31, 2010 20 0.1325 mg/l DS000 Accepted
Lead Jan 1, 2008 – Dec 31, 2010 20 0.0017 mg/l DS000 Accepted
Copper Jan 1, 2005 – Dec 31, 2007 20 0.0483 mg/l DS000 Accepted
Lead Jan 1, 2005 – Dec 31, 2007 20 0.0015 mg/l DS000 Accepted
Copper Jan 1, 2002 – Dec 31, 2004 40 0.0046 mg/l DS000 Accepted
Lead Jan 1, 2002 – Dec 31, 2004 40 0 mg/l DS000 Accepted
Copper Jan 1, 1999 – Dec 31, 2001 20 0.026 mg/l DS000 Accepted
Lead Jan 1, 1999 – Dec 31, 2001 20 0.002 mg/l DS000 Accepted
Copper Jan 1, 1996 – Dec 31, 1998 20 0 mg/l DS000 Accepted
Lead Jan 1, 1996 – Dec 31, 1998 20 0 mg/l DS000 Accepted
Copper Jan 1, 1995 – Dec 31, 1995 20 0 mg/l DS000 Accepted
Lead Jan 1, 1995 – Dec 31, 1995 20 0.002 mg/l DS000 Accepted
Copper Jan 1, 1993 – Jun 30, 1993 40 0 mg/l DS000 Accepted
Lead Jan 1, 1993 – Jun 30, 1993 40 0 mg/l DS000 Accepted

No date of receipt is recorded for any of these summaries.

This system’s violations

What the 90th percentile is

The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.

From the help text published with these pages.