This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0400018 , Freeny W/A #2-Rosebud System
22 of the 57 analytes this system has been tested for have been detected at least once, across 302 samples on record.
The other 35 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 302 samples on record, detections range from October 1, 2003 to September 23, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 60 of 60 results | Jul 30, 2007 | Aug 29, 2023 |
| Barium 1010 | Inorganic Chemical | 27 of 27 results | Oct 1, 2003 | Mar 10, 2025 |
| Lead 1030 | Inorganic Chemical | 22 of 60 results | Jul 30, 2007 | Aug 29, 2023 |
| TTHM 2950 | Organic Chemical | 20 of 20 results | Jun 28, 2004 | Sep 23, 2025 |
| Chromium 1020 | Inorganic Chemical | 17 of 27 results | Oct 1, 2003 | Apr 29, 2020 |
| Chloroform 2941 | Organic Chemical | 16 of 16 results | Aug 21, 2007 | Sep 23, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 15 of 20 results | Aug 21, 2007 | Sep 23, 2025 |
| Bromodichloromethane 2943 | Organic Chemical | 15 of 16 results | Aug 21, 2007 | Sep 23, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 15 of 16 results | Aug 21, 2007 | Sep 23, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 15 of 15 results | Mar 7, 2012 | Oct 4, 2012 |
| Dichloroacetic Acid 2451 | Organic Chemical | 11 of 15 results | Sep 28, 2009 | Sep 23, 2025 |
| Trichloroacetic Acid 2452 | Organic Chemical | 10 of 15 results | Sep 28, 2009 | Sep 23, 2025 |
| Fluoride 1025 | Inorganic Chemical | 10 of 27 results | Mar 28, 2005 | Feb 12, 2024 |
| Sodium 1052 | Inorganic Chemical | 9 of 9 results | Sep 24, 2019 | Feb 11, 2025 |
| Xylenes, Total 2955 | Organic Chemical | 9 of 61 results | Apr 1, 2009 | Jan 26, 2012 |
| Sulfate 1055 | Inorganic Chemical | 4 of 4 results | Oct 1, 2003 | Mar 1, 2004 |
| Ethylbenzene 2992 | Organic Chemical | 3 of 61 results | Apr 1, 2009 | Nov 2, 2009 |
| Dichloromethane 2964 | Organic Chemical | 2 of 61 results | Aug 12, 2004 | Aug 12, 2004 |
| Dibromoacetic Acid 2454 | Organic Chemical | 1 of 15 results | Sep 23, 2025 | Sep 23, 2025 |
| Monochloroacetic Acid 2450 | Organic Chemical | 1 of 15 results | Aug 17, 2015 | Aug 17, 2015 |
| Nickel 1036 | Inorganic Chemical | 1 of 27 results | Mar 31, 2014 | Mar 31, 2014 |
| Selenium 1045 | Inorganic Chemical | 1 of 27 results | Mar 1, 2004 | Mar 1, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 271–280 of 302 samples, newest first — collected March 28, 2005 to July 12, 2006. The summary above covers all 302.
40 results from the 10 samples listed here: 4 detected, 36 not detected. Across the whole record it is 284 of 2,175. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF101 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF101 | Nitrate 1040 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF101 | Nitrite 1041 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF102 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF102 | Nitrate 1040 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Jul 12, 2006, sampling point TF102 | Nitrite 1041 EPA method 353.2 | Jan 1, 2006 – Dec 31, 2006 |
|
||
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Arsenic 1005 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| 0.019192 mg/l , sample collected Mar 1, 2006, sampling point TF102 | Barium 1010 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Cadmium 1015 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| 0.000705 mg/l , sample collected Mar 1, 2006, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Fluoride 1025 EPA method 380-75WE | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0002 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Mercury 1035 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Selenium 1045 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF102 | Uranium-238 4009 | Not recorded |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Arsenic 1005 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| 0.023281 mg/l , sample collected Mar 1, 2006, sampling point TF101 | Barium 1010 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Cadmium 1015 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| 0.000553 mg/l , sample collected Mar 1, 2006, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Fluoride 1025 EPA method 380-75WE | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0002 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Mercury 1035 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Selenium 1045 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2005 – Dec 31, 2007 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Mar 1, 2006, sampling point TF101 | Uranium-238 4009 | Not recorded |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF102 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF102 | Nitrate 1040 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF102 | Nitrite 1041 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF101 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF101 | Nitrate 1040 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Aug 22, 2005, sampling point TF101 | Nitrite 1041 EPA method 353.2 | Jan 1, 2005 – Dec 31, 2005 |
|
||
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Mar 28, 2005, sampling point TF101 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Mar 28, 2005, sampling point TF102 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2005 – Dec 31, 2007 |
-
- Collected
- Jul 12, 2006
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 060713-015NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2006 – Dec 31, 2006
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jul 12, 2006
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 060713-016NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2006 – Dec 31, 2006
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Mar 1, 2006
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 060302-067CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
-
- Collected
- Mar 1, 2006
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 060302-062CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
-
- Collected
- Mar 1, 2006
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 060302-067IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Barium 1010 EPA method 200.8
- Result
- 0.019192 mg/l
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Chromium 1020 EPA method 200.8
- Result
- 0.000705 mg/l
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Fluoride 1025 EPA method 380-75WE
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0002 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Uranium-238 4009
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
- Collected
- Mar 1, 2006
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 060302-066IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Barium 1010 EPA method 200.8
- Result
- 0.023281 mg/l
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Chromium 1020 EPA method 200.8
- Result
- 0.000553 mg/l
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Fluoride 1025 EPA method 380-75WE
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0002 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0001 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Uranium-238 4009
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
- Collected
- Aug 22, 2005
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 050823-123NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2005
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Aug 22, 2005
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 050823-128NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2005
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Mar 28, 2005
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 050329-060CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
-
- Collected
- Mar 28, 2005
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 050329-064CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.005 mg/l Minimum Reporting Level
Routine (10).