This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0410011 , Town of Plantersville
18 of the 58 analytes this system has been tested for have been detected at least once, across 283 samples on record.
The other 40 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 283 samples on record, detections range from October 1, 2003 to April 9, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 60 of 60 results | Jul 30, 2007 | Aug 28, 2023 |
| Barium 1010 | Inorganic Chemical | 30 of 30 results | Oct 1, 2003 | Mar 11, 2025 |
| Fluoride 1025 | Inorganic Chemical | 19 of 30 results | Oct 1, 2003 | Mar 11, 2025 |
| Lead 1030 | Inorganic Chemical | 18 of 60 results | Jul 30, 2007 | Aug 28, 2023 |
| Nickel 1036 | Inorganic Chemical | 16 of 30 results | Oct 1, 2003 | Mar 11, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 15 of 15 results | Mar 12, 2012 | Oct 5, 2012 |
| Chromium 1020 | Inorganic Chemical | 11 of 30 results | Oct 1, 2003 | Apr 22, 2015 |
| TTHM 2950 | Organic Chemical | 9 of 23 results | Aug 20, 2007 | Apr 9, 2025 |
| Sodium 1052 | Inorganic Chemical | 9 of 9 results | Sep 19, 2019 | Feb 18, 2025 |
| Sulfate 1055 | Inorganic Chemical | 6 of 6 results | Oct 1, 2003 | Mar 1, 2004 |
| Dibromochloromethane 2944 | Organic Chemical | 5 of 17 results | Sep 11, 2018 | Nov 7, 2024 |
| Selenium 1045 | Inorganic Chemical | 5 of 30 results | Oct 1, 2003 | Mar 1, 2006 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 4 of 23 results | Sep 28, 2009 | Sep 22, 2021 |
| Bromoform 2942 | Organic Chemical | 3 of 17 results | Jul 25, 2013 | Aug 12, 2019 |
| Nitrite 1041 | Inorganic Chemical | 1 of 66 results | Mar 10, 2021 | Mar 10, 2021 |
| Monobromoacetic Acid 2453 | Organic Chemical | 1 of 17 results | Sep 15, 2020 | Sep 15, 2020 |
| Monochloroacetic Acid 2450 | Organic Chemical | 1 of 17 results | Aug 12, 2019 | Aug 12, 2019 |
| Dichloromethane 2964 | Organic Chemical | 1 of 21 results | Aug 12, 2004 | Aug 12, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 161–170 of 283 samples, newest first — collected August 1, 2012 to October 4, 2012. The summary above covers all 283.
22 results from the 10 samples listed here: 4 detected, 18 not detected. Across the whole record it is 214 of 1,409. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.6 pci/l , sample collected Oct 4, 2012 14:14, sampling point TF101 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.42 pci/l Minimum Reporting Level , sample collected Oct 4, 2012 14:14, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.344 pci/l Minimum Reporting Level , sample collected Oct 4, 2012 14:14, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Oct 1, 2012 – Dec 31, 2012 |
| Not detected below 0.42 pci/l Minimum Reporting Level , sample collected Oct 4, 2012 14:14, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 15 ug/l Minimum Reporting Level , sample collected Aug 29, 2012 02:30, sampling point TF103 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2011 – Dec 31, 2013 |
|
||
| Not detected below 15 ug/l Minimum Reporting Level , sample collected Aug 29, 2012 02:00, sampling point TF101 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2011 – Dec 31, 2013 |
|
||
| Not detected below 15 ug/l Minimum Reporting Level , sample collected Aug 29, 2012 01:45, sampling point TF102 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2011 – Dec 31, 2013 |
|
||
| 0.5 pci/l , sample collected Aug 1, 2012 12:47, sampling point TF102 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.57 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 12:47, sampling point TF102 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.286 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 12:47, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| Not detected below 0.57 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 12:47, sampling point TF102 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 0.5 pci/l , sample collected Aug 1, 2012 13:15, sampling point TF103 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:15, sampling point TF103 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.213 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:15, sampling point TF103 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:15, sampling point TF103 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| 0.6 pci/l , sample collected Aug 1, 2012 13:00, sampling point TF101 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
| Not detected below 0.42 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:00, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
| Not detected below 0.344 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:00, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jul 1, 2012 – Sep 30, 2012 |
| Not detected below 0.42 pci/l Minimum Reporting Level , sample collected Aug 1, 2012 13:00, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 1, 2012 13:15, sampling point TF103 | Combined Uranium 4006 EPA method 200.8 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 1, 2012 13:00, sampling point TF101 | Combined Uranium 4006 EPA method 200.8 | Jul 1, 2012 – Sep 30, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 1, 2012 12:47, sampling point TF102 | Combined Uranium 4006 EPA method 200.8 | Jul 1, 2012 – Sep 30, 2012 |
-
- Collected
- Oct 4, 2012 14:14
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 121005-068
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 0.6 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.42 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.344 pci/l Minimum Reporting Level
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.42 pci/l Minimum Reporting Level
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
- Collected
- Aug 29, 2012 02:30
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 120830-003CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 15 ug/l Minimum Reporting Level
-
- Collected
- Aug 29, 2012 02:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120830-002CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 15 ug/l Minimum Reporting Level
-
- Collected
- Aug 29, 2012 01:45
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120830-001CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 15 ug/l Minimum Reporting Level
-
- Collected
- Aug 1, 2012 12:47
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120802-084
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 0.5 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.57 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.286 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.57 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Aug 1, 2012 13:15
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 120802-097
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 0.5 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.213 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Aug 1, 2012 13:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120802-096
- Laboratory
- Radiation Safety Engineering
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 0.6 pci/l
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.42 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.344 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.42 pci/l Minimum Reporting Level
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
- Collected
- Aug 1, 2012 13:15
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 120802-097RU
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Aug 1, 2012 13:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120802-096RU
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Aug 1, 2012 12:47
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120802-084RU
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2012 – Sep 30, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
Routine (10).