This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0410041 , North Lee W/A-Beech Springs
41 of the 75 analytes this system has been tested for have been detected at least once, across 374 samples on record.
The other 34 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 374 samples on record, detections range from October 1, 2003 to May 19, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 108 of 108 results | Nov 27, 2012 | Jul 30, 2025 |
| Lead 1030 | Inorganic Chemical | 55 of 108 results | Nov 27, 2012 | Jul 29, 2025 |
| Barium 1010 | Inorganic Chemical | 36 of 36 results | Oct 1, 2003 | Apr 8, 2025 |
| Fluoride 1025 | Inorganic Chemical | 32 of 39 results | Oct 1, 2003 | Apr 8, 2025 |
| Nickel 1036 | Inorganic Chemical | 31 of 36 results | Oct 1, 2003 | Apr 8, 2025 |
| Chromium 1020 | Inorganic Chemical | 22 of 36 results | Oct 1, 2003 | Apr 8, 2025 |
| Arsenic 1005 | Inorganic Chemical | 20 of 36 results | Mar 1, 2006 | Apr 8, 2025 |
| TTHM 2950 | Organic Chemical | 11 of 27 results | Jun 11, 2012 | May 19, 2026 |
| Selenium 1045 | Inorganic Chemical | 11 of 36 results | Oct 1, 2003 | Mar 11, 2025 |
| Bromoform 2942 | Organic Chemical | 10 of 18 results | Jun 11, 2012 | May 19, 2026 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 10 of 12 results | Mar 6, 2012 | Oct 3, 2012 |
| Sodium 1052 | Inorganic Chemical | 8 of 8 results | Sep 21, 2017 | Feb 12, 2025 |
| Sulfate 1055 | Inorganic Chemical | 7 of 7 results | Oct 1, 2003 | Sep 21, 2017 |
| Dibromochloromethane 2944 | Organic Chemical | 5 of 18 results | Oct 12, 2016 | Jun 19, 2024 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 4 of 26 results | Aug 26, 2015 | Apr 16, 2025 |
| Dibromoacetic Acid 2454 | Organic Chemical | 3 of 17 results | Aug 26, 2015 | Jun 25, 2018 |
| Calcium 1016 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Chloride 1017 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Iron 1028 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Magnesium 1031 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Manganese 1032 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Potassium 1042 | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Residue, Total, Filterable 1057 | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Color 1905 | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Hardness, Total (As Caco3) 1915 | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Alkalinity, Total 1927 | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Iron, Field Result FEFD | Inorganic Chemical | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| Calculated Sodium NACA | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| PH, Field Result PHFD | Water Quality | 3 of 3 results | Sep 21, 2017 | Sep 21, 2017 |
| 1,2-Dibromo-3-Chloropropane 2931 | Organic Chemical | 2 of 2 results | Apr 6, 2020 | Apr 6, 2020 |
| Ethylene Dibromide 2946 | Organic Chemical | 2 of 2 results | Apr 6, 2020 | Apr 6, 2020 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 2 of 12 results | Apr 5, 2018 | Jan 15, 2020 |
| Radium-226 4020 | Radionuclide | 2 of 12 results | Apr 5, 2018 | Jan 15, 2020 |
| Radium-228 4030 | Radionuclide | 2 of 12 results | Apr 5, 2018 | Jan 15, 2020 |
| Alkalinity, Caco3 Stability 1067 | Water Quality | 2 of 2 results | Sep 21, 2017 | Sep 21, 2017 |
| Thallium, Total 1085 | Inorganic Chemical | 2 of 36 results | Mar 30, 2005 | Nov 3, 2011 |
| Carbon Dioxide 1901 | Water Quality | 1 of 1 result | Sep 21, 2017 | Sep 21, 2017 |
| Bromodichloromethane 2943 | Organic Chemical | 1 of 18 results | Oct 12, 2016 | Oct 12, 2016 |
| Cyanide 1024 | Inorganic Chemical | 1 of 31 results | Nov 2, 2011 | Nov 2, 2011 |
| Nitrite 1041 | Inorganic Chemical | 1 of 60 results | Nov 2, 2011 | Nov 2, 2011 |
| Dichloromethane 2964 | Organic Chemical | 1 of 55 results | Aug 12, 2004 | Aug 12, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 221–230 of 374 samples, newest first — collected April 2, 2014 to June 4, 2014. The summary above covers all 374.
41 results from the 10 samples listed here: 20 detected, 21 not detected. Across the whole record it is 431 of 2,317. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.0398 mg/l , sample collected Jun 4, 2014 05:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
| 0.0015 mg/l , sample collected Jun 4, 2014 05:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
|
||
| 0.2443 mg/l , sample collected Jun 4, 2014 10:21, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
| 0.0007 mg/l , sample collected Jun 4, 2014 10:21, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
|
||
| 0.4879 mg/l , sample collected Jun 4, 2014 06:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
| 0.001 mg/l , sample collected Jun 4, 2014 06:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
|
||
| 0.1504 mg/l , sample collected Jun 4, 2014 07:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
| 0.0023 mg/l , sample collected Jun 4, 2014 07:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
|
||
| 0.0392 mg/l , sample collected Jun 3, 2014 10:15, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
| 0.0007 mg/l , sample collected Jun 3, 2014 10:15, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2014 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:24, sampling point TF101 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:24, sampling point TF101 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:24, sampling point TF101 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:40, sampling point TF102 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:40, sampling point TF102 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:40, sampling point TF102 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:00, sampling point TF103 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:00, sampling point TF103 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 16, 2014 12:00, sampling point TF103 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2014 – Dec 31, 2014 |
|
||
| 0.0008 mg/l , sample collected Apr 2, 2014 01:00, sampling point TF101 | Arsenic 1005 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| 0.1471 mg/l , sample collected Apr 2, 2014 01:00, sampling point TF101 | Barium 1010 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Cadmium 1015 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| 0.0051 mg/l , sample collected Apr 2, 2014 01:00, sampling point TF101 | Chromium 1020 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| 0.19 mg/l , sample collected Apr 2, 2014 01:00, sampling point TF101 | Fluoride 1025 EPA method 300.0 | Jan 1, 2012 – Dec 31, 2014 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Mercury 1035 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| 0.0014 mg/l , sample collected Apr 2, 2014 01:00, sampling point TF101 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Selenium 1045 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:00, sampling point TF101 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2012 – Dec 31, 2014 |
|
||
| 0.0006 mg/l , sample collected Apr 2, 2014 01:25, sampling point TF102 | Arsenic 1005 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| 0.1485 mg/l , sample collected Apr 2, 2014 01:25, sampling point TF102 | Barium 1010 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Cadmium 1015 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| 0.006 mg/l , sample collected Apr 2, 2014 01:25, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| 0.148 mg/l , sample collected Apr 2, 2014 01:25, sampling point TF102 | Fluoride 1025 EPA method 300.0 | Jan 1, 2014 – Dec 31, 2016 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Mercury 1035 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| 0.0014 mg/l , sample collected Apr 2, 2014 01:25, sampling point TF102 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Selenium 1045 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2014 01:25, sampling point TF102 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2014 – Dec 31, 2016 |
-
- Collected
- Jun 4, 2014 05:30
- Sampling point
- DS000 Distribution DS000
- Sample type
- Routine
- Lab sample
- 140605-025PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0398 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0015 mg/l
-
- Collected
- Jun 4, 2014 10:21
- Sampling point
- DS000 Distribution DS000
- Sample type
- Routine
- Lab sample
- 140605-024PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.2443 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0007 mg/l
-
- Collected
- Jun 4, 2014 06:30
- Sampling point
- DS000 Distribution DS000
- Sample type
- Routine
- Lab sample
- 140605-023PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.4879 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.001 mg/l
-
- Collected
- Jun 4, 2014 07:30
- Sampling point
- DS000 Distribution DS000
- Sample type
- Routine
- Lab sample
- 140605-022PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.1504 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0023 mg/l
-
- Collected
- Jun 3, 2014 10:15
- Sampling point
- DS000 Distribution DS000
- Sample type
- Routine
- Lab sample
- 140605-021PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0392 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0007 mg/l
-
- Collected
- Apr 16, 2014 12:24
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 140417-088NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Apr 16, 2014 12:40
- Sampling point
- TF102 Treatment Facility TF102
- Sample type
- Routine
- Lab sample
- 140417-029NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Apr 16, 2014 12:00
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 140417-008NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2014
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Apr 2, 2014 01:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 140403-039IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- 0.0008 mg/l
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Barium 1010 EPA method 200.8
- Result
- 0.1471 mg/l
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Chromium 1020 EPA method 200.8
- Result
- 0.0051 mg/l
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Fluoride 1025 EPA method 300.0
- Result
- 0.19 mg/l
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Nickel 1036 EPA method 200.8
- Result
- 0.0014 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2014
-
- Collected
- Apr 2, 2014 01:25
- Sampling point
- TF102 Treatment Facility TF102
- Sample type
- Routine
- Lab sample
- 140403-038IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- 0.0006 mg/l
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Barium 1010 EPA method 200.8
- Result
- 0.1485 mg/l
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Chromium 1020 EPA method 200.8
- Result
- 0.006 mg/l
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Fluoride 1025 EPA method 300.0
- Result
- 0.148 mg/l
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Nickel 1036 EPA method 200.8
- Result
- 0.0014 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
Routine (10).