Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Gross Alpha, Incl. Radon & U results

MS0450005 , Cameron Community Water System, Inc

12 samples have been analysed for Gross Alpha, Incl. Radon & U at Cameron Community Water System, Inc.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Gross Alpha, Incl. Radon & U result

The table below lists 1–10 of 12 samples, newest first — collected February 14, 2012 to September 16, 2019.

10 Gross Alpha, Incl. Radon & U results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 24 results for other analytes, which are on the full results page.

Gross Alpha, Incl. Radon & U results for Cameron Community Water System, Inc, from 1 to 10 of 12 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Sep 16, 2019 11:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
4424996
Laboratory
Eurofins Eaton Analytical South Bend in
2 pci/l , sample collected Sep 16, 2019 11:30, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Jan 1, 2013 – Dec 31, 2021
Collected
Jun 12, 2018 15:10
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
3962919
Laboratory
Eurofins Eaton Analytical South Bend in
6 pci/l , sample collected Jun 12, 2018 15:10, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Jan 1, 2013 – Dec 31, 2021
Collected
Jul 18, 2012 14:46
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
201211120184
Laboratory
Radiation Safety Engineering
1 pci/l , sample collected Jul 18, 2012 14:46, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Jul 18, 2012 14:34
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201211120182
Laboratory
Radiation Safety Engineering
0.8 pci/l , sample collected Jul 18, 2012 14:34, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Jul 16, 2012 13:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120718-007
Laboratory
Radiation Safety Engineering
1 pci/l , sample collected Jul 16, 2012 13:30, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Jul 16, 2012 14:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120718-006
Laboratory
Radiation Safety Engineering
0.8 pci/l , sample collected Jul 16, 2012 14:00, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Apr 23, 2012 13:00
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120424-047
Laboratory
Radiation Safety Engineering
1 pci/l , sample collected Apr 23, 2012 13:00, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Apr 23, 2012 13:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120424-046
Laboratory
Radiation Safety Engineering
0.8 pci/l , sample collected Apr 23, 2012 13:30, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Feb 14, 2012 11:00
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120215-050
Laboratory
Radiation Safety Engineering
1 pci/l , sample collected Feb 14, 2012 11:00, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Feb 14, 2012 11:45
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120215-049
Laboratory
Radiation Safety Engineering
0.8 pci/l , sample collected Feb 14, 2012 11:45, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded

Routine (10).