This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Combined Radium (-226 & -228) results
MS0450006 , City of Canton
7 samples have been analysed for Combined Radium (-226 & -228) at City of Canton.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Combined Radium (-226 & -228) result
All 7 samples analysed for this analyte are listed below, newest first. No date range is applied.
7 Combined Radium (-226 & -228) results from the 7 samples listed here: 1 detected, 6 not detected. Those samples also carried 27 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 1.85 pci/l , sample collected Sep 18, 2019 14:15, sampling point TF080 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.36 pci/l Minimum Reporting Level , sample collected Nov 18, 2013 13:25, sampling point TF081 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.38 pci/l Minimum Reporting Level , sample collected Sep 10, 2013 09:27, sampling point TF081 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF081 | Combined Radium (-226 & -228) 4010 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Feb 18, 2009, sampling point TF080 | Combined Radium (-226 & -228) 4010 | Jan 1, 2009 – Mar 31, 2009 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Dec 29, 2008, sampling point TF081 | Combined Radium (-226 & -228) 4010 | Oct 1, 2008 – Dec 31, 2008 |
|
||
| Not detected below 1 pci/l Minimum Reporting Level , sample collected Dec 29, 2008, sampling point TF080 | Combined Radium (-226 & -228) 4010 | Oct 1, 2008 – Dec 31, 2008 |
-
- Collected
- Sep 18, 2019 14:15
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 4430051
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 1.85 pci/l
-
- Collected
- Nov 18, 2013 13:25
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 201402280139
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.36 pci/l Minimum Reporting Level
-
- Collected
- Sep 10, 2013 09:27
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 201309260163
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.38 pci/l Minimum Reporting Level
-
- Collected
- Feb 18, 2009
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 225720034
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Feb 18, 2009
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 225720033
- Laboratory
- Gel Laboratories
- Monitoring period
- Jan 1, 2009 – Mar 31, 2009
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Dec 29, 2008
- Sampling point
- TF081 Treatment Plant T081
- Sample type
- Routine
- Lab sample
- 221965034
- Laboratory
- Gel Laboratories
- Monitoring period
- Oct 1, 2008 – Dec 31, 2008
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 1 pci/l Minimum Reporting Level
-
- Collected
- Dec 29, 2008
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 221965024
- Laboratory
- Gel Laboratories
- Monitoring period
- Oct 1, 2008 – Dec 31, 2008
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 1 pci/l Minimum Reporting Level
Routine (7).