Combined Radium (-226 & -228) results

MS0450013 , City of Ridgeland

32 samples have been analysed for Combined Radium (-226 & -228) at City of Ridgeland.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Combined Radium (-226 & -228) result

The table below lists 1–10 of 32 samples, newest first — collected November 5, 2012 to September 3, 2019.

10 Combined Radium (-226 & -228) results from the 10 samples listed here: 3 detected, 7 not detected. Those samples also carried 22 results for other analytes, which are on the full results page.

Combined Radium (-226 & -228) results for City of Ridgeland, from 1 to 10 of 32 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Sep 3, 2019 14:00
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
4410152
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.51 pci/l Minimum Reporting Level , sample collected Sep 3, 2019 14:00, sampling point TF103 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Sep 3, 2019 13:45
Sampling point
TF104 Treatment Plant T104
Sample type
Routine
Lab sample
4410150
Laboratory
Eurofins Eaton Analytical South Bend in
0.37 pci/l , sample collected Sep 3, 2019 13:45, sampling point TF104 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Sep 3, 2019 13:30
Sampling point
TF105 Treatment Plant T105
Sample type
Routine
Lab sample
4410148
Laboratory
Eurofins Eaton Analytical South Bend in
0.42 pci/l , sample collected Sep 3, 2019 13:30, sampling point TF105 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Sep 3, 2019 13:00
Sampling point
TF106 Treatment Plant T106
Sample type
Routine
Lab sample
4410146
Laboratory
Eurofins Eaton Analytical South Bend in
0.45 pci/l , sample collected Sep 3, 2019 13:00, sampling point TF106 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Aug 1, 2018 09:40
Sampling point
TF103 Treatment Plant T103
Sample type
Routine
Lab sample
4009845
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Aug 1, 2018 09:40, sampling point TF103 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Aug 1, 2018 09:20
Sampling point
TF104 Treatment Plant T104
Sample type
Routine
Lab sample
4009843
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.44 pci/l Minimum Reporting Level , sample collected Aug 1, 2018 09:20, sampling point TF104 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Aug 1, 2018 09:00
Sampling point
TF105 Treatment Plant T105
Sample type
Routine
Lab sample
4009841
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Aug 1, 2018 09:00, sampling point TF105 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Aug 1, 2018 08:30
Sampling point
TF106 Treatment Plant T106
Sample type
Routine
Lab sample
4009839
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Aug 1, 2018 08:30, sampling point TF106 Combined Radium (-226 & -228) 4010 EPA method 7500-RA Not recorded
Collected
Jan 14, 2013 08:10
Sampling point
TF107 Treatment Plant T107
Sample type
Routine
Lab sample
130115-017
Laboratory
Radiation Safety Engineering
Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Jan 14, 2013 08:10, sampling point TF107 Combined Radium (-226 & -228) 4010 Not recorded
Collected
Nov 5, 2012 08:35
Sampling point
TF107 Treatment Plant T107
Sample type
Routine
Lab sample
121106-012
Laboratory
Radiation Safety Engineering
Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Nov 5, 2012 08:35, sampling point TF107 Combined Radium (-226 & -228) 4010 Not recorded

Routine (10).