This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0450021 , Bear Creek W/A-West
26 of the 59 analytes this system has been tested for have been detected at least once, across 642 samples on record.
The other 33 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 642 samples on record, detections range from October 6, 2003 to June 25, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 240 of 240 results | Jun 15, 2004 | Aug 2, 2024 |
| Lead 1030 | Inorganic Chemical | 174 of 240 results | Jun 15, 2004 | Aug 1, 2024 |
| TTHM 2950 | Organic Chemical | 52 of 54 results | Mar 17, 2004 | Jun 25, 2026 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 47 of 55 results | Sep 21, 2005 | Jun 25, 2026 |
| Barium 1010 | Inorganic Chemical | 47 of 47 results | Oct 6, 2003 | Mar 10, 2025 |
| Fluoride 1025 | Inorganic Chemical | 47 of 47 results | Oct 6, 2003 | Mar 10, 2025 |
| Chloroform 2941 | Organic Chemical | 34 of 34 results | Jul 31, 2006 | Jun 25, 2026 |
| Dichloroacetic Acid 2451 | Organic Chemical | 33 of 33 results | Jul 30, 2008 | Jun 25, 2026 |
| Trichloroacetic Acid 2452 | Organic Chemical | 30 of 33 results | Aug 25, 2009 | Jun 25, 2026 |
| Bromodichloromethane 2943 | Organic Chemical | 27 of 34 results | Jul 31, 2006 | Jun 12, 2018 |
| Chromium 1020 | Inorganic Chemical | 21 of 47 results | Oct 6, 2003 | Apr 10, 2019 |
| Sodium 1052 | Inorganic Chemical | 15 of 15 results | Sep 20, 2019 | Feb 25, 2025 |
| Monochloroacetic Acid 2450 | Organic Chemical | 13 of 33 results | Nov 4, 2013 | Jun 24, 2020 |
| Nickel 1036 | Inorganic Chemical | 8 of 47 results | Dec 5, 2007 | Mar 10, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 8 of 34 results | Jul 31, 2006 | Aug 6, 2014 |
| Sulfate 1055 | Inorganic Chemical | 8 of 8 results | Oct 6, 2003 | Mar 17, 2004 |
| Radium-226 4020 | Radionuclide | 5 of 16 results | Sep 9, 2019 | Sep 9, 2019 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 3 of 6 results | Jun 19, 2018 | Sep 9, 2019 |
| Bromoform 2942 | Organic Chemical | 2 of 34 results | Jul 31, 2006 | Aug 17, 2010 |
| Selenium 1045 | Inorganic Chemical | 2 of 47 results | Jan 11, 2010 | Jan 11, 2010 |
| Nitrate 1040 | Inorganic Chemical | 2 of 108 results | Jul 24, 2006 | Jul 24, 2006 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 1 of 16 results | Sep 9, 2019 | Sep 9, 2019 |
| Radium-228 4030 | Radionuclide | 1 of 16 results | Sep 9, 2019 | Sep 9, 2019 |
| Monobromoacetic Acid 2453 | Organic Chemical | 1 of 33 results | Jun 19, 2013 | Jun 19, 2013 |
| Thallium, Total 1085 | Inorganic Chemical | 1 of 47 results | Nov 19, 2008 | Nov 19, 2008 |
| Nitrite 1041 | Inorganic Chemical | 1 of 108 results | May 24, 2004 | May 24, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 151–160 of 642 samples, newest first — collected September 9, 2019 to September 20, 2019. The summary above covers all 642.
16 results from the 10 samples listed here: 11 detected, 5 not detected. Across the whole record it is 823 of 2,943. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 96000 ug/l , sample collected Sep 20, 2019 12:15, sampling point TF106 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| 86000 ug/l , sample collected Sep 20, 2019 11:30, sampling point TF105 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| 64000 ug/l , sample collected Sep 20, 2019 10:30, sampling point TF104 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| 83000 ug/l , sample collected Sep 20, 2019 10:00, sampling point TF103 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Sep 9, 2019 12:15, sampling point TF104 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
| 0.49 pci/l , sample collected Sep 9, 2019 12:15, sampling point TF104 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2019 – Dec 31, 2027 |
| Not detected below 0.6 pci/l Minimum Reporting Level , sample collected Sep 9, 2019 12:15, sampling point TF104 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2019 – Dec 31, 2027 |
|
||
| 2.2 pci/l , sample collected Sep 9, 2019 12:00, sampling point TF104 | Gross Alpha, Incl. Radon & U 4002 EPA method 7110B | Jan 1, 2019 – Dec 31, 2027 |
|
||
| 2.12 pci/l , sample collected Sep 9, 2019 14:45, sampling point TF106 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
| 0.42 pci/l , sample collected Sep 9, 2019 14:45, sampling point TF106 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2019 – Dec 31, 2027 |
| 1.7 pci/l , sample collected Sep 9, 2019 14:45, sampling point TF106 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2019 – Dec 31, 2027 |
|
||
| 1.5 pci/l , sample collected Sep 9, 2019 14:30, sampling point TF106 | Gross Alpha, Incl. Radon & U 4002 EPA method 7110B | Jan 1, 2019 – Dec 31, 2027 |
|
||
| Not detected below 0.7 pci/l Minimum Reporting Level , sample collected Sep 9, 2019 14:05, sampling point TF103 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
| 0.36 pci/l , sample collected Sep 9, 2019 14:05, sampling point TF103 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2019 – Dec 31, 2027 |
| Not detected below 0.7 pci/l Minimum Reporting Level , sample collected Sep 9, 2019 14:05, sampling point TF103 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2019 – Dec 31, 2027 |
|
||
| Not detected below 2.4 pci/l Minimum Reporting Level , sample collected Sep 9, 2019 13:50, sampling point TF103 | Gross Alpha, Incl. Radon & U 4002 EPA method 7110B | Jan 1, 2019 – Dec 31, 2027 |
-
- Collected
- Sep 20, 2019 12:15
- Sampling point
- TF106
- Sample type
- Routine
- Lab sample
- 680-174569-23
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 96000 ug/l
-
- Collected
- Sep 20, 2019 11:30
- Sampling point
- TF105 Treatment Plant T105
- Sample type
- Routine
- Lab sample
- 680-174569-22
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 86000 ug/l
-
- Collected
- Sep 20, 2019 10:30
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 680-174569-21
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 64000 ug/l
-
- Collected
- Sep 20, 2019 10:00
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 680-174569-20
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 83000 ug/l
-
- Collected
- Sep 9, 2019 12:15
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 4416336
- Laboratory
- Eurofins Eaton Analytical South Bend in
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 7500-RAB
- Result
- 0.49 pci/l
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Radium-228 4030 EPA method 7500-RAD
- Result
- Not detected below 0.6 pci/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
- Collected
- Sep 9, 2019 12:00
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 4416331
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Gross Alpha, Incl. Radon & U 4002 EPA method 7110B
- Result
- 2.2 pci/l
-
- Collected
- Sep 9, 2019 14:45
- Sampling point
- TF106
- Sample type
- Routine
- Lab sample
- 4416335
- Laboratory
- Eurofins Eaton Analytical South Bend in
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 2.12 pci/l
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 7500-RAB
- Result
- 0.42 pci/l
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Radium-228 4030 EPA method 7500-RAD
- Result
- 1.7 pci/l
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
- Collected
- Sep 9, 2019 14:30
- Sampling point
- TF106
- Sample type
- Routine
- Lab sample
- 4416330
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Gross Alpha, Incl. Radon & U 4002 EPA method 7110B
- Result
- 1.5 pci/l
-
- Collected
- Sep 9, 2019 14:05
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 4416334
- Laboratory
- Eurofins Eaton Analytical South Bend in
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.7 pci/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 7500-RAB
- Result
- 0.36 pci/l
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Radium-228 4030 EPA method 7500-RAD
- Result
- Not detected below 0.7 pci/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
- Collected
- Sep 9, 2019 13:50
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 4416329
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2019 – Dec 31, 2027
-
Gross Alpha, Incl. Radon & U 4002 EPA method 7110B
- Result
- Not detected below 2.4 pci/l Minimum Reporting Level
Routine (10).