TTHM results
MS0460005 , Foxworth Water & Sewerage Assn
19 samples have been analysed for TTHM at Foxworth Water & Sewerage Assn.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every TTHM result
The table below lists 11–19 of 19 samples, newest first — collected July 12, 2004 to May 9, 2023.
9 TTHM results from the 9 samples listed here: 6 detected, 3 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.
Units in this table
TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 2.44 ug/l , sample collected May 9, 2023 13:19, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 7, 2022 14:51, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Not recorded |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 22, 2021 15:08, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2021 – Dec 31, 2021 |
|
||
| Not detected below 4 ug/l Minimum Reporting Level , sample collected Sep 29, 2020 13:01, sampling point MRT000 | TTHM 2950 | Jan 1, 2020 – Dec 31, 2020 |
|
||
| 2.38 ug/l , sample collected Jul 13, 2016 13:28, sampling point MRT000 | TTHM 2950 | Jan 1, 2014 – Dec 31, 2016 |
|
||
| 9.4 ug/l , sample collected Aug 21, 2013 13:45, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 10, 2010, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| 9 ug/l , sample collected Aug 23, 2007, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2007 |
|
||
| 11.3 ug/l , sample collected Jul 12, 2004, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2004 – Dec 31, 2004 |
-
- Collected
- May 9, 2023 13:19
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- TH-230510-013
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 2.44 ug/l
-
- Collected
- Jun 7, 2022 14:51
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- TH-220608-003
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Sep 22, 2021 15:08
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- TH-210923-005
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2021 – Dec 31, 2021
-
TTHM 2950 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
-
- Collected
- Sep 29, 2020 13:01
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 200930-010TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2020
-
TTHM 2950
- Result
- Not detected below 4 ug/l Minimum Reporting Level
-
- Collected
- Jul 13, 2016 13:28
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 160714-001TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
TTHM 2950
- Result
- 2.38 ug/l
-
- Collected
- Aug 21, 2013 13:45
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 130822-015TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
TTHM 2950 EPA method 524.2
- Result
- 9.4 ug/l
-
- Collected
- Jun 10, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100611-005TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
TTHM 2950 EPA method 524.2
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Aug 23, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070824-014TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
TTHM 2950 EPA method 524.2
- Result
- 9 ug/l
-
- Collected
- Jul 12, 2004
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 040713-021TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2004 – Dec 31, 2004
-
TTHM 2950 EPA method 524.2
- Result
- 11.3 ug/l
Routine (9).