Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0460011 , Morgantown Water Association

14 of the 56 analytes this system has been tested for have been detected at least once, across 117 samples on record.

The other 42 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 117 samples on record, detections range from October 8, 2003 to February 4, 2026. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Morgantown Water Association, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 36 of 36 results Sep 23, 2004 Sep 6, 2023
Lead 1030 Inorganic Chemical 24 of 36 results Sep 23, 2004 Sep 6, 2023
Barium 1010 Inorganic Chemical 8 of 8 results Oct 8, 2003 Feb 7, 2024
Fluoride 1025 Inorganic Chemical 7 of 8 results Oct 8, 2003 Feb 7, 2024
Chromium 1020 Inorganic Chemical 5 of 8 results Oct 8, 2003 Feb 29, 2016
Nitrate-Nitrite 1038 Inorganic Chemical 3 of 21 results Mar 7, 2018 Feb 4, 2026
Nitrate 1040 Inorganic Chemical 3 of 21 results Mar 7, 2018 Feb 4, 2026
Sodium 1052 Inorganic Chemical 3 of 3 results Sep 18, 2019 Feb 26, 2025
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 2 of 7 results Jun 9, 2010 Oct 18, 2022
TTHM 2950 Organic Chemical 2 of 7 results Sep 17, 2007 Jun 9, 2010
Sulfate 1055 Inorganic Chemical 2 of 2 results Oct 8, 2003 Mar 8, 2004
Combined Radium (-226 & -228) 4010 Radionuclide 1 of 6 results Dec 15, 2015 Dec 15, 2015
Radium-226 4020 Radionuclide 1 of 6 results Dec 15, 2015 Dec 15, 2015
Nickel 1036 Inorganic Chemical 1 of 8 results Oct 18, 2010 Oct 18, 2010

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 1–10 of 117 samples, newest first — collected September 6, 2023 to February 4, 2026. The summary above covers all 117.

28 results from the 10 samples listed here: 11 detected, 17 not detected. Across the whole record it is 98 of 485. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

We withheld the location of 1 sampling point below. The location on record identifies a private home, and we do not publish those. That is our decision, not the agency’s. The sampling point, its type and every result taken there are published unchanged.

Chemical and radiological sample results for Morgantown Water Association, every result from 1 to 10 of 117 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Feb 4, 2026 14:30
Sampling point
WL001 Well W001
Sample type
Routine
Lab sample
NI-260205-032
Laboratory
MSDH Lab
0.119 mg/l , sample collected Feb 4, 2026 14:30, sampling point WL001 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
0.119 mg/l , sample collected Feb 4, 2026 14:30, sampling point WL001 Nitrate 1040 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Feb 4, 2026 14:30, sampling point WL001 Nitrite 1041 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
Collected
Feb 26, 2025 12:25
Sampling point
WL001 Well W001
Sample type
Routine
Lab sample
NA-250227-026
Laboratory
MSDH Lab
78.6 mg/l , sample collected Feb 26, 2025 12:25, sampling point WL001 Sodium 1052 EPA method 200.7 Jan 1, 2023 – Dec 31, 2025
Collected
Feb 26, 2025 12:15
Sampling point
SMD Location withheld
Sample type
Routine
Lab sample
TH-250227-011
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Feb 26, 2025 12:15, sampling point SMD TTHM 2950 EPA method 524.2 Jan 1, 2023 – Dec 31, 2025
Collected
Feb 26, 2025 12:20
Sampling point
SMD Location withheld
Sample type
Routine
Lab sample
HA-250227-011
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Feb 26, 2025 12:20, sampling point SMD Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2023 – Dec 31, 2025
Collected
Mar 20, 2024 12:45
Sampling point
WL001 Well W001
Sample type
Routine
Lab sample
NI-240321-014
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 20, 2024 12:45, sampling point WL001 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2024 – Dec 31, 2024
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 20, 2024 12:45, sampling point WL001 Nitrate 1040 EPA method QC10107041C Jan 1, 2024 – Dec 31, 2024
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 20, 2024 12:45, sampling point WL001 Nitrite 1041 EPA method QC10107041C Jan 1, 2024 – Dec 31, 2024
Collected
Feb 7, 2024 13:15
Sampling point
WL001 Well W001
Sample type
Routine
Lab sample
IN-240208-023
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Arsenic 1005 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
0.0065 mg/l , sample collected Feb 7, 2024 13:15, sampling point WL001 Barium 1010 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Cadmium 1015 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Chromium 1020 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
0.218 mg/l , sample collected Feb 7, 2024 13:15, sampling point WL001 Fluoride 1025 EPA method QC 10-109-12-2-A Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Mercury 1035 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Nickel 1036 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Selenium 1045 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Antimony, Total 1074 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.00001 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Beryllium, Total 1075 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Feb 7, 2024 13:15, sampling point WL001 Thallium, Total 1085 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Sep 6, 2023 07:45
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
PB-230907-136
Laboratory
MSDH Lab
0.0519 mg/l , sample collected Sep 6, 2023 07:45, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Sep 6, 2023 07:45, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
Collected
Sep 6, 2023 06:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
PB-230907-135
Laboratory
MSDH Lab
0.0723 mg/l , sample collected Sep 6, 2023 06:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
1.1 ug/l , sample collected Sep 6, 2023 06:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
Collected
Sep 6, 2023 06:50
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
PB-230907-134
Laboratory
MSDH Lab
0.0411 mg/l , sample collected Sep 6, 2023 06:50, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
6.3 ug/l , sample collected Sep 6, 2023 06:50, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
Collected
Sep 6, 2023 06:05
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
PB-230907-133
Laboratory
MSDH Lab
0.0055 mg/l , sample collected Sep 6, 2023 06:05, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Sep 6, 2023 06:05, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2021 – Dec 31, 2023

Routine (10).