Gross Alpha, Incl. Radon & U results

MS0470002 , City of Holly Springs

8 samples have been analysed for Gross Alpha, Incl. Radon & U at City of Holly Springs.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Gross Alpha, Incl. Radon & U result

All 8 samples analysed for this analyte are listed below, newest first. No date range is applied.

8 Gross Alpha, Incl. Radon & U results from the 8 samples listed here: 7 detected, 1 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.

Gross Alpha, Incl. Radon & U results for City of Holly Springs, from the 8 samples analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jul 23, 2026 12:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
810-201496-1
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 3 pci/l Minimum Reporting Level , sample collected Jul 23, 2026 12:00, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Jan 1, 2025 – Dec 31, 2030
Collected
Sep 11, 2019 13:50
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
4419916
Laboratory
Eurofins Eaton Analytical South Bend in
4.4 pci/l , sample collected Sep 11, 2019 13:50, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Jan 1, 2019 – Dec 31, 2024
Collected
Jun 19, 2018 14:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
3968433
Laboratory
Eurofins Eaton Analytical South Bend in
2.9 pci/l , sample collected Jun 19, 2018 14:00, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Jan 1, 2013 – Dec 31, 2018
Collected
Oct 11, 2012 13:12
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
201301120231
Laboratory
Radiation Safety Engineering
4.7 pci/l , sample collected Oct 11, 2012 13:12, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Oct 10, 2012 14:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
121011-077
Laboratory
Radiation Safety Engineering
4.7 pci/l , sample collected Oct 10, 2012 14:00, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Aug 6, 2012 14:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120807-129
Laboratory
Radiation Safety Engineering
4.7 pci/l , sample collected Aug 6, 2012 14:00, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
May 22, 2012 14:40
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120523-100
Laboratory
Radiation Safety Engineering
4.7 pci/l , sample collected May 22, 2012 14:40, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Collected
Mar 13, 2012 13:12
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120314-131
Laboratory
Radiation Safety Engineering
4.7 pci/l , sample collected Mar 13, 2012 13:12, sampling point TF080 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded