Chemical and radiological sample results

MS0470069 , South Victoria

17 of the 57 analytes this system has been tested for have been detected at least once, across 215 samples on record.

The other 40 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 215 samples on record, detections range from October 8, 2003 to July 23, 2026. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for South Victoria, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 69 of 69 results Sep 20, 2004 Aug 13, 2024
Lead 1030 Inorganic Chemical 60 of 69 results Sep 20, 2004 Jul 6, 2021
Nitrate-Nitrite 1038 Inorganic Chemical 42 of 46 results May 24, 2004 Jul 7, 2026
Nitrate 1040 Inorganic Chemical 42 of 46 results May 24, 2004 Jul 7, 2026
Barium 1010 Inorganic Chemical 22 of 22 results Oct 8, 2003 Jul 23, 2026
Chromium 1020 Inorganic Chemical 13 of 22 results Oct 8, 2003 Mar 11, 2025
Gross Alpha, Incl. Radon & U 4002 Radionuclide 10 of 10 results Dec 13, 2011 Jul 18, 2012
Combined Radium (-226 & -228) 4010 Radionuclide 10 of 10 results Dec 13, 2011 Jul 18, 2012
Nickel 1036 Inorganic Chemical 9 of 20 results Mar 8, 2004 Mar 11, 2025
Sodium 1052 Inorganic Chemical 6 of 6 results Sep 23, 2019 Feb 26, 2025
Radium-226 4020 Radionuclide 5 of 10 results Dec 13, 2011 Jul 18, 2012
Radium-228 4030 Radionuclide 5 of 10 results Dec 13, 2011 Jul 18, 2012
Fluoride 1025 Inorganic Chemical 4 of 22 results Jan 11, 2010 Apr 9, 2019
Selenium 1045 Inorganic Chemical 3 of 22 results Apr 4, 2005 Mar 8, 2006
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 2 of 7 results Jun 14, 2010 Oct 18, 2022
TTHM 2950 Organic Chemical 2 of 7 results Aug 20, 2007 Jun 14, 2010
Nitrite 1041 Inorganic Chemical 1 of 46 results May 7, 2007 May 7, 2007

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 91–100 of 215 samples, newest first — collected July 17, 2012 to March 4, 2013. The summary above covers all 215.

46 results from the 10 samples listed here: 21 detected, 25 not detected. Across the whole record it is 305 of 939. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for South Victoria, every result from 91 to 100 of 215 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Mar 4, 2013 02:45
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
130305-040NI
Laboratory
MSDH Lab
1.66 mg/l , sample collected Mar 4, 2013 02:45, sampling point TF102 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
1.66 mg/l , sample collected Mar 4, 2013 02:45, sampling point TF102 Nitrate 1040 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 4, 2013 02:45, sampling point TF102 Nitrite 1041 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Collected
Mar 4, 2013 02:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
130305-030NI
Laboratory
MSDH Lab
0.83 mg/l , sample collected Mar 4, 2013 02:30, sampling point TF101 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
0.83 mg/l , sample collected Mar 4, 2013 02:30, sampling point TF101 Nitrate 1040 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 4, 2013 02:30, sampling point TF101 Nitrite 1041 EPA method 353.2 Jan 1, 2013 – Dec 31, 2013
Collected
Sep 24, 2012 03:25
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120925-017CN
Laboratory
MSDH Lab
Not detected below 15 ug/l Minimum Reporting Level , sample collected Sep 24, 2012 03:25, sampling point TF101 Cyanide 1024 EPA method QC10204001X Jan 1, 2011 – Dec 31, 2013
Collected
Sep 24, 2012 03:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120925-016CN
Laboratory
MSDH Lab
Not detected below 15 ug/l Minimum Reporting Level , sample collected Sep 24, 2012 03:30, sampling point TF102 Cyanide 1024 EPA method QC10204001X Jan 1, 2011 – Dec 31, 2013
Collected
Jul 18, 2012 12:15
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
201211120181
Laboratory
Radiation Safety Engineering
2.8 pci/l , sample collected Jul 18, 2012 12:15, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
0.6 pci/l , sample collected Jul 18, 2012 12:15, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.201 pci/l Minimum Reporting Level , sample collected Jul 18, 2012 12:15, sampling point TF102 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
0.6 pci/l , sample collected Jul 18, 2012 12:15, sampling point TF102 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 18, 2012 12:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201211120084
Laboratory
Radiation Safety Engineering
2.5 pci/l , sample collected Jul 18, 2012 12:30, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
0.7 pci/l , sample collected Jul 18, 2012 12:30, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
0.7 pci/l , sample collected Jul 18, 2012 12:30, sampling point TF101 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
Not detected below 0.23 pci/l Minimum Reporting Level , sample collected Jul 18, 2012 12:30, sampling point TF101 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 18, 2012 02:21
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120719-020IN
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Arsenic 1005 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.01157 mg/l , sample collected Jul 18, 2012 02:21, sampling point TF101 Barium 1010 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Cadmium 1015 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.00102 mg/l , sample collected Jul 18, 2012 02:21, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Fluoride 1025 EPA method 380-75WE Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Mercury 1035 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Nickel 1036 EPA method 200.8 Not recorded
Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Selenium 1045 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Antimony, Total 1074 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Beryllium, Total 1075 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:21, sampling point TF101 Thallium, Total 1085 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Collected
Jul 18, 2012 02:35
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120719-019IN
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Arsenic 1005 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.01598 mg/l , sample collected Jul 18, 2012 02:35, sampling point TF102 Barium 1010 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Cadmium 1015 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.00124 mg/l , sample collected Jul 18, 2012 02:35, sampling point TF102 Chromium 1020 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Fluoride 1025 EPA method 380-75WE Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Mercury 1035 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
0.00055 mg/l , sample collected Jul 18, 2012 02:35, sampling point TF102 Nickel 1036 EPA method 200.8 Not recorded
Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Selenium 1045 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Antimony, Total 1074 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Beryllium, Total 1075 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 18, 2012 02:35, sampling point TF102 Thallium, Total 1085 EPA method 200.8 Jan 1, 2011 – Dec 31, 2013
Collected
Jul 17, 2012 15:20
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120718-015
Laboratory
Radiation Safety Engineering
2.8 pci/l , sample collected Jul 17, 2012 15:20, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
0.6 pci/l , sample collected Jul 17, 2012 15:20, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.201 pci/l Minimum Reporting Level , sample collected Jul 17, 2012 15:20, sampling point TF102 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
0.6 pci/l , sample collected Jul 17, 2012 15:20, sampling point TF102 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 17, 2012 15:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120718-014
Laboratory
Radiation Safety Engineering
2.5 pci/l , sample collected Jul 17, 2012 15:00, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
0.7 pci/l , sample collected Jul 17, 2012 15:00, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
0.7 pci/l , sample collected Jul 17, 2012 15:00, sampling point TF101 Radium-226 4020 EPA method 903.1 Jul 1, 2012 – Sep 30, 2012
Not detected below 0.23 pci/l Minimum Reporting Level , sample collected Jul 17, 2012 15:00, sampling point TF101 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012

Routine (10).