This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0470105 , Marshall Co Water Assn
18 of the 61 analytes this system has been tested for have been detected at least once, across 449 samples on record.
The other 43 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 449 samples on record, detections range from October 8, 2003 to July 9, 2026. These figures cover the whole record; the list of samples further down is narrowed.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 313 of 313 results | Sep 23, 2004 | Jul 30, 2024 |
| Lead 1030 | Inorganic Chemical | 184 of 313 results | Sep 23, 2004 | Jul 30, 2024 |
| Barium 1010 | Inorganic Chemical | 14 of 14 results | Oct 8, 2003 | Mar 11, 2025 |
| Sodium 1052 | Inorganic Chemical | 8 of 8 results | Sep 17, 2019 | Feb 25, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 5 of 5 results | Dec 14, 2011 | Jul 19, 2012 |
| Calcium 1016 | Inorganic Chemical | 4 of 4 results | Nov 19, 2021 | Dec 1, 2021 |
| Chloride 1017 | Inorganic Chemical | 4 of 4 results | Nov 19, 2021 | Dec 1, 2021 |
| Conductivity @ 25 C Umhos/CM 1064 | Water Quality | 4 of 4 results | Nov 19, 2021 | Dec 1, 2021 |
| Alkalinity, Total 1927 | Water Quality | 4 of 4 results | Nov 19, 2021 | Dec 1, 2021 |
| Xylenes, Total 2955 | Organic Chemical | 3 of 15 results | Aug 2, 2023 | Jul 9, 2026 |
| Nickel 1036 | Inorganic Chemical | 3 of 14 results | Mar 10, 2004 | Mar 11, 2025 |
| Chromium 1020 | Inorganic Chemical | 2 of 14 results | Mar 1, 2016 | Jul 12, 2023 |
| Sulfate 1055 | Inorganic Chemical | 2 of 6 results | Nov 19, 2021 | Nov 19, 2021 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 2 of 20 results | Aug 28, 2007 | Jun 17, 2010 |
| TTHM 2950 | Organic Chemical | 2 of 21 results | Aug 28, 2007 | Jun 17, 2010 |
| Color 1905 | Water Quality | 1 of 4 results | Dec 1, 2021 | Dec 1, 2021 |
| Dichloromethane 2964 | Organic Chemical | 1 of 15 results | Aug 26, 2004 | Aug 26, 2004 |
| Selenium 1045 | Inorganic Chemical | 1 of 14 results | Mar 10, 2004 | Mar 10, 2004 |
Showing samples collected between September 25, 2024 and September 25, 2026. That is this page’s default, not a limit on what the agency records.
Choose a date range
The most recent samples, result by result
The table below lists 21–23 of 23 samples, newest first — collected October 9, 2024 to October 9, 2024. The summary above covers all 23.
23 results from the 3 samples listed here: 0 detected, 23 not detected. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Xylenes, Total 2955 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Dichloromethane 2964 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | O-Dichlorobenzene 2968 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | P-Dichlorobenzene 2969 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Vinyl Chloride 2976 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,2-Dichloroethane 2980 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Carbon Tetrachloride 2982 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,2-Dichloropropane 2983 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Trichloroethylene 2984 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Tetrachloroethylene 2987 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Chlorobenzene 2989 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Benzene 2990 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Toluene 2991 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Ethylbenzene 2992 EPA method 524.2 | Not recorded |
| Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Oct 9, 2024 11:12, sampling point TF081 | Styrene 2996 EPA method 524.2 | Not recorded |
|
||
| Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Oct 9, 2024 11:00, sampling point TF081 | Cyanide 1024 EPA method QC10204001X | Oct 1, 2024 – Dec 31, 2024 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 9, 2024 10:50, sampling point TF081 | Combined Uranium 4006 EPA method 200.8 | Oct 1, 2024 – Dec 31, 2024 |
-
- Collected
- Oct 9, 2024 11:12
- Sampling point
- TF081 TF081
- Sample type
- Routine
- Lab sample
- VO-241010-003
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.5 ug/l Minimum Reporting Level
-
- Collected
- Oct 9, 2024 11:00
- Sampling point
- TF081 TF081
- Sample type
- Routine
- Lab sample
- CN-241010-006
- Laboratory
- MSDH Lab
- Monitoring period
- Oct 1, 2024 – Dec 31, 2024
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.015 mg/l Minimum Reporting Level
-
- Collected
- Oct 9, 2024 10:50
- Sampling point
- TF081 TF081
- Sample type
- Routine
- Lab sample
- RU-241010-002
- Laboratory
- MSDH Lab
- Monitoring period
- Oct 1, 2024 – Dec 31, 2024
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
Routine (3).