This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Combined Radium (-226 & -228) results
MS0480013 , Wren W/A
27 samples have been analysed for Combined Radium (-226 & -228) at Wren W/A.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Combined Radium (-226 & -228) result
The table below lists 1–10 of 27 samples, newest first — collected October 10, 2012 to September 17, 2019.
10 Combined Radium (-226 & -228) results from the 10 samples listed here: 0 detected, 10 not detected. Those samples also carried 28 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Sep 17, 2019 12:00, sampling point TF101 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Jul 24, 2018 12:00, sampling point TF101 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
|
||
| Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 16:05, sampling point TF103 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.35 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 15:35, sampling point TF106 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 14:30, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 14:00, sampling point TF105 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.47 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 15:00, sampling point TF104 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Oct 10, 2012 15:25, sampling point TF103 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.35 pci/l Minimum Reporting Level , sample collected Oct 10, 2012 15:00, sampling point TF106 | Combined Radium (-226 & -228) 4010 | Not recorded |
|
||
| Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Oct 10, 2012 15:50, sampling point TF101 | Combined Radium (-226 & -228) 4010 | Not recorded |
-
- Collected
- Sep 17, 2019 12:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 4427016
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.4 pci/l Minimum Reporting Level
-
- Collected
- Jul 24, 2018 12:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 4001473
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 16:05
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 201301120228
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.46 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 15:35
- Sampling point
- TF106
- Sample type
- Routine
- Lab sample
- 201301120227
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.35 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 14:30
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 201301120225
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.4 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 14:00
- Sampling point
- TF105 Treatment Plant T105
- Sample type
- Routine
- Lab sample
- 201301120224
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.46 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 15:00
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 201301120223
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.47 pci/l Minimum Reporting Level
-
- Collected
- Oct 10, 2012 15:25
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 121011-065
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.46 pci/l Minimum Reporting Level
-
- Collected
- Oct 10, 2012 15:00
- Sampling point
- TF106
- Sample type
- Routine
- Lab sample
- 121011-054
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.35 pci/l Minimum Reporting Level
-
- Collected
- Oct 10, 2012 15:50
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 121011-064
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Combined Radium (-226 & -228) 4010
- Result
- Not detected below 0.4 pci/l Minimum Reporting Level
Routine (10).