This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Lead and copper
MS0490006 , North District 1 Water Assn.
Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.
| Analyte | Monitoring period | Samples | 90th percentile | Facility | Data quality |
|---|---|---|---|---|---|
| Copper | Jan 1, 2023 – Dec 31, 2025 | 10 | 0.113 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2023 – Dec 31, 2025 | 10 | 0.0016 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2022 – Dec 31, 2022 | 10 | 0.18 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2022 – Dec 31, 2022 | 10 | 0.0019 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2021 – Dec 31, 2021 | 10 | 0.586 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2021 – Dec 31, 2021 | 10 | 0.0018 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2020 – Dec 31, 2020 | 10 | 0.1669 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2020 – Dec 31, 2020 | 10 | 0.0016 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2019 – Dec 31, 2019 | 20 | 0.0787 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2019 – Dec 31, 2019 | 20 | 0.0013 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2019 – Jun 30, 2019 | 20 | 0.0772 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2019 – Jun 30, 2019 | 20 | 0.0014 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2018 – Dec 31, 2018 | 20 | 0.2463 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2018 – Dec 31, 2018 | 20 | 0.0027 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2018 – Jun 30, 2018 | 20 | 0.2167 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2018 – Jun 30, 2018 | 20 | 0.015 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2017 – Dec 31, 2017 | 10 | 1.0711 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2017 – Dec 31, 2017 | 10 | 0.0202 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2017 – Jun 30, 2017 | 20 | 0.2257 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2017 – Jun 30, 2017 | 20 | 0.0023 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2016 – Dec 31, 2016 | 20 | 1.1567 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2016 – Dec 31, 2016 | 20 | 0.0157 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2016 – Jun 30, 2016 | 20 | 1.1062 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2016 – Jun 30, 2016 | 20 | 0.0122 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2015 – Dec 31, 2015 | 20 | 1.3872 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2015 – Dec 31, 2015 | 20 | 0.0156 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2015 – Jun 30, 2015 | 20 | 0.1038 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2015 – Jun 30, 2015 | 20 | 0.0066 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2012 – Dec 31, 2014 | 10 | 0.7838 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2012 – Dec 31, 2014 | 10 | 0.0177 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2009 – Dec 31, 2011 | 10 | 0.0224 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2009 – Dec 31, 2011 | 10 | 0.0027 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2006 – Dec 31, 2008 | 10 | 0.8057 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2006 – Dec 31, 2008 | 10 | 0.0082 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2003 – Dec 31, 2005 | 10 | 1.075 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2003 – Dec 31, 2005 | 10 | 0.011 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2000 – Dec 31, 2002 | 70 | 0.798 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2000 – Dec 31, 2002 | 70 | 0.011 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.615 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.005 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1995 – Dec 31, 1995 | 10 | 0.582 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1995 – Dec 31, 1995 | 10 | 0.006 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1994 – Jun 30, 1994 | 20 | 0.288 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1994 – Jun 30, 1994 | 20 | 0.004 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1993 – Dec 31, 1993 | 20 | 0.479 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1993 – Dec 31, 1993 | 20 | 0.015 mg/l | DS000 | Accepted |
No date of receipt is recorded for any of these summaries.
What the 90th percentile is
The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.
From the help text published with these pages.